ASTM D4584-2005(2010) Standard Test Method for Measuring Apparent pH of Electrocoat Baths《电涂镀槽表观pH值测量的标准试验方法》.pdf
《ASTM D4584-2005(2010) Standard Test Method for Measuring Apparent pH of Electrocoat Baths《电涂镀槽表观pH值测量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4584-2005(2010) Standard Test Method for Measuring Apparent pH of Electrocoat Baths《电涂镀槽表观pH值测量的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4584 05 (Reapproved 2010)Standard Test Method forMeasuring Apparent pH of Electrocoat Baths1This standard is issued under the fixed designation D4584; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of the freehydrogen ion concentration of electrocoat baths and theirultrafiltrates.1
3、.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro
4、-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD1293 Test Methods for pH of WaterE70 Test Method for pH of Aqueous Solutions With theGlass ElectrodeE180 Practi
5、ce for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial and Spe-cialty Chemicals33. Summary of Test Method3.1 A specimen of a well-agitated electrocoat bath is placedin a stirrer-equipped container and the pH measured with a pHmeter and associated glass and reference e
6、lectrodes.4. Significance and Use4.1 The pH is the measure of the free hydrogen ionconcentration of a sample, and it indicates whether an electro-coat bath is acidic, neutral, or basic. Since pH measurements ofgood precision are made in aqueous solutions, it is suggestedthat the pH measurements of e
7、lectrocoat baths are onlysemi-quantitative, and therefore such measurements should bereferred to as apparent pH measurements.4.2 The pH of electrocoat paints is used for research,production, and quality control or electrocoat bath processcontrol.4.3 Other related methods for determining the pH of wa
8、teror aqueous systems are described in Test Methods D1293 andE70.5. Apparatus5.1 pH Meter,5.2 Glass and Reference Electrodes.NOTE 1Due to the polarity of electrocoat materials it is desirable touse a separate set of electrodes for each bath polarity, cathodic and anodic,because a bath of opposite po
9、larity poisons the electrodes. A desiredpractice is to rinse the electrodes after each measurement with anappropriate solvent for the electrocoat material.5.3 Thermometer, capable of 0.5C accuracy with a 2 to32C range.6. Reagents6.1 Reference Standard Solutions, commercial standards ofpH 4.0, 7.0, a
10、nd 10.0.6.2 Purity of WaterReferences to water shall be under-stood to mean water conforming to Type II of SpecificationD1193.7. Sampling and Sample Preparation7.1 The sample should be obtained while the electrocoatbath is under proper circulation so that a uniform material isobtained. In case of an
11、 ultrafiltrate, the material should bethoroughly mixed or stirred prior to sampling to assureuniformity.1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, andApplications and is the direct responsibility ofSubcommittee D01.21 on Chemical Analys
12、is of Paints and Paint Materials.Current edition approved June 1, 2010. Published June 2010. Originallyapproved in 1986. Last previous edition approved in 2005 as D4584 - 05. DOI:10.1520/D4584-05R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service
13、 at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700,
14、West Conshohocken, PA 19428-2959, United States.7.2 After sampling and prior to removing a test specimen itis mandatory that the sample be shaken or stirred until it ishomogeneous and free of any settled material. This is particu-larly important if there is any delay between the sampling ofthe bath
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD458420052010STANDARDTESTMETHODFORMEASURINGAPPARENTPHOFELECTROCOATBATHS 电涂镀槽 表观 PH 测量 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-517433.html