ASTM D3161-2008c Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method).pdf
《ASTM D3161-2008c Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method).pdf》由会员分享,可在线阅读,更多相关《ASTM D3161-2008c Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method).pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3161 08cStandard Test Method forWind-Resistance of Asphalt Shingles (Fan-Induced Method)1This standard is issued under the fixed designation D 3161; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the procedure for ev
3、aluating thewind resistance of asphalt shingles that results from theshingles rigidity (with or without contribution from sealant) ormechanical interlocking (with or without contribution fromsealant) or any combination thereof. The shingles are appliedto a test panel in accordance with the manufactu
4、rers instruc-tions and tested at a 2:12 (17 %) slope, or at the lowest slopepermitted by those instructions.1.2 The values stated in SI units are to be regarded asstandard. The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are
5、 not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations pri
6、or to use.2. Referenced Documents2.1 ASTM Standards:2D 1079 Terminology Relating to Roofing and Waterproof-ing3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Terminology D 1079.4. Classes of Shingles4.1 Shingles are of three classes:4.1.1 Class APass at a test
7、 velocity of 97 km/h (60 mph).4.1.2 Class DPass at a test velocity of 145 km/h (90mph).4.1.3 Class FPass at a test velocity of 177 km/h (110mph).5. Significance and Use5.1 Most asphalt shingles that have demonstrated windresistance by this test have also performed well in use. Naturalwind conditions
8、 differ with respect to intensity, duration, andturbulence; these conditions are beyond the means of this testto simulate. The results of this test do not directly correlate towind speeds experienced in service, and no accommodation ismade in this test method for building height, building exposureca
9、tegory, or building importance factor.5.2 Many factors influence the wind resistance of shinglesin the field; for example, temperature, time, roof slope,contamination by dirt and debris, and fasteners that aremisaligned or under-driven. It is beyond the scope of this testmethod to address all of the
10、se influences. This test method isdesigned to evaluate the wind resistance of asphalt shingles asdescribed in the scope when representative samples are appliedto test panels in accordance with the manufacturers instruc-tions and conditioned as specified before testing.6. Apparatus6.1 Test Machine, c
11、apable of delivering a horizontal streamof air through a rectangular opening 914 mm (36 in.) wide and305 mm (12 in.) high at a velocity not less than 97 km/h (60mph). At a velocity of not less than 177 km/h (110 mph), it ispermissible to add a duct section to the equipment to lower theheight of the
12、rectangular opening to 152 mm (6 in.). The testvelocity shall not vary more than 65 mph as measured at aminimum of three evenly spaced locations across the orifice.The machine shall be equipped with an adjustable stand toreceive a test panel and be adapted to setting the test panel atany desired slo
13、pe, at any horizontal distance from the loweredge of the duct opening, and at various angles incident to thewind direction.6.2 Timer, capable of reading to the nearest minute.6.3 Mechanical Circulation Conditioning Cell or Room,having forced circulation of air capable of receiving a 1.27-m(50-in.) w
14、ide by 1.68-m (66-in.) long, or larger test panel on aslope of 2:12 (17 %) and of maintaining a uniform temperatureof 57 to 60C (135 to 140F).1This test method is under the jurisdiction of ASTM Committee D08 on Roofingand Waterproofing and is the direct responsibility of Subcommittee D08.02 onPrepar
15、ed Roofings, Shingles and Siding Materials.Current edition approved Dec. 1, 2008. Published December 2008. Originallyapproved in 1972. Last previous edition approved in 2008 as D 3161 08b.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at service
16、astm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Test Samples7.1 The test panels shall be of plywood, ti
17、ghtly matchedsheathing boards, or other suitable decking material and notless than 1.27 by 1.68 m (50 by 66 in.) in size. They are to beof such rigidity that they will not twist or distort with normalhandling, or vibrate from the wind velocity during the test.7.2 Apply shingles to duplicate panels,
18、parallel to the shortdimension of the panel, in the normal manner recommended bythe manufacturer. Use roofing nails, properly positioned inaccordance with the manufacturers instructions, to fasten eachshingle. Do not apply pressure to the shingle tabs either duringor after application.7.3 Apply lock
19、-type shingles to an additional two panels,parallel to the short dimension of the panel, in accordance withthe manufacturers instructions.7.4 Secure the shingles at the outer edge of each test panelby exposed nailing to simulate anchoring at the rake edges ofa roof deck.7.5 Control the temperature a
20、t 27 6 8C (80 6 15F) andmaintain the slope of the panel at 2:12 (17 %) during applica-tion of the shingles.8. Conditioning of Shingle Test Panels8.1 Maintain the test panels at a slope of 2:12 (17 %) and ata temperature of 27 6 8C (80 6 15F) until beginning heatconditioning.8.2 Place the test panels
21、 in the conditioning cell or room ona slope of 2:12 (17 %) and maintain at a temperature of 57 to60C (135 to 140F) for a continuous period of 16 h.8.3 After completion of the conditioning period, allow thetest panels to come to room temperature 27 6 8C (80 6 15F)while being maintained at a slope of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD31612008CSTANDARDTESTMETHODFORWINDRESISTANCEOFASPHALTSHINGLESFANINDUCEDMETHODPDF

链接地址:http://www.mydoc123.com/p-514190.html