ASTM D1319-2010 Standard Test Method for Hydrocarbon Types in Liquid Petroleum Products by Fluorescent Indicator Adsorption《荧光指示剂吸附法测定液体石油产品中的烃类的标准试验方法》.pdf
《ASTM D1319-2010 Standard Test Method for Hydrocarbon Types in Liquid Petroleum Products by Fluorescent Indicator Adsorption《荧光指示剂吸附法测定液体石油产品中的烃类的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1319-2010 Standard Test Method for Hydrocarbon Types in Liquid Petroleum Products by Fluorescent Indicator Adsorption《荧光指示剂吸附法测定液体石油产品中的烃类的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1319 10Designation: 156/97Standard Test Method forHydrocarbon Types in Liquid Petroleum Products byFluorescent Indicator Adsorption1This standard is issued under the fixed designation D1319; the number immediately following the designation indicates the year oforiginal adoption or, in
2、the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 Th
3、is test method covers the determination of hydrocar-bon types over the concentration ranges from 5 to 99 volume %aromatics, 0.3 to 55 volume % olefins, and 1 to 95 volume %saturates in petroleum fractions that distill below 315C. Thistest method may apply to concentrations outside these ranges,but t
4、he precision has not been determined. Samples containingdark-colored components that interfere in reading the chro-matographic bands cannot be analyzed.NOTE 1For the determination of olefins below 0.3 volume %, othertest methods are available, such as Test Method D2710.1.2 This test method is intend
5、ed for use with full boilingrange products. Cooperative data have established that theprecision statement does not apply to narrow boiling petroleumfractions near the 315C limit. Such samples are not elutedproperly, and results are erratic.1.3 The applicability of this test method to products derive
6、dfrom fossil fuels other than petroleum, such as coal, shale, ortar sands, has not been determined, and the precision statementmay or may not apply to such products.1.4 This test method has two precision statements depictedin tables. The first table is applicable to unleaded fuels that donot contain
7、 oxygenated blending components. It may or maynot apply to automotive gasolines containing lead antiknockmixtures. The second table is applicable to oxygenate blended(for example, MTBE, ethanol) automotive spark ignition fuelsamples with a concentration range of 1340 volume percentaromatics, 433 vol
8、ume percent olefins, and 4568 volumepercent saturates.1.5 The oxygenated blending components, methanol, etha-nol, methyl-tert-butylether (MTBE), tert-amylmethylether(TAME), and ethyl-tert-butylether (ETBE), do not interferewith the determination of hydrocarbon types at concentrationsnormally found i
9、n commercial blends. These oxygenatedcomponents are not detected since they elute with the alcoholdesorbent. Other oxygenated compounds shall be individuallyverified. When samples containing oxygenated blending com-ponents are analyzed, correct the results to a total-sample basis.1.6 WARNINGMercury
10、has been designated by manyregulatory agencies as a hazardous material that can causecentral nervous system, kidney and liver damage. Mercury, orits vapor, may be hazardous to health and corrosive tomaterials. Caution should be taken when handling mercury andmercury containing products. See the appl
11、icable product Ma-terial Safety Data Sheet (MSDS) for details and EPAswebsitehttp:/www.epa.gov/mercury/faq.htmfor addi-tional information. Users should be aware that selling mercuryand/or mercury containing products into your state or countrymay be prohibited by law.1.7 The values stated in SI units
12、 are to be regarded asstandard. No other units of measurement are included in thisstandard.1.8 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practi
13、ces and determine the applica-bility of regulatory limitations prior to use. For specificwarning statements, see Section 7, 8.1, and 10.5.2. Referenced Documents2.1 ASTM Standards:2D86 Test Method for Distillation of Petroleum Products atAtmospheric Pressure1This test method is under the jurisdictio
14、n of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.04.0C on Liquid Chromatography.In the IP, this test method is under the jurisdiction of the StandardizationCommittee. This test method has been approved by the sponsoring committees andacc
15、epted by the cooperating societies in accordance with established procedures.Current edition approved May 1, 2010. Published June 2010. Originallyapproved in 1954. Last previous edition approved in 2008 as D131908. DOI:10.1520/D1319-10.2For referenced ASTM standards, visit the ASTM website, www.astm
16、.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Bo
17、x C700, West Conshohocken, PA 19428-2959, United States.D1655 Specification for Aviation Turbine FuelsD2710 Test Method for Bromine Index of Petroleum Hy-drocarbons by Electrometric TitrationD3663 Test Method for Surface Area of Catalysts andCatalyst CarriersD4057 Practice for Manual Sampling of Pet
18、roleum andPetroleum ProductsD4815 Test Method for Determination of MTBE, ETBE,TAME, DIPE, tertiary-Amyl Alcohol and C1to C4Alco-hols in Gasoline by Gas ChromatographyD5599 Test Method for Determination of Oxygenates inGasoline by Gas Chromatography and Oxygen SelectiveFlame Ionization DetectionE11 S
19、pecification for Woven Wire Test Sieve Cloth and TestSieves2.2 Other Standards:GC/OFID EPA Test MethodOxygen and Oxygenate Con-tent Analysis3BS 4101:2000 Test sieves. Technical requirements andtesting. Test sieves of metal wire cloth43. Terminology3.1 Definitions of Terms Specific to This Standard:3
20、.1.1 aromaticsthe volume % of monocyclic and polycy-clic aromatics, plus aromatic olefins, some dienes, compoundscontaining sulfur and nitrogen, or higher boiling oxygenatedcompounds (excluding those listed in 1.5).3.1.2 olefinsthe volume % of alkenes, plus cycloalkenes,and some dienes.3.1.3 saturat
21、esthe volume % of alkanes, plus cycloal-kanes.4. Summary of Test Method4.1 Approximately 0.75 mL of sample is introduced into aspecial glass adsorption column packed with activated silicagel. A small layer of the silica gel contains a mixture offluorescent dyes. When all the sample has been adsorbed
22、 on thegel, alcohol is added to desorb the sample down the column.The hydrocarbons are separated in accordance with theiradsorption affinities into aromatics, olefins, and saturates. Thefluorescent dyes are also separated selectively, with the hydro-carbon types, and make the boundaries of the aroma
23、tic, olefin,and saturate zones visible under ultraviolet light. The volumepercentage of each hydrocarbon type is calculated from thelength of each zone in the column.5. Significance and Use5.1 The determination of the total volume % of saturates,olefins, and aromatics in petroleum fractions is impor
24、tant incharacterizing the quality of petroleum fractions as gasolineblending components and as feeds to catalytic reformingprocesses. This information is also important in characterizingpetroleum fractions and products from catalytic reforming andfrom thermal and catalytic cracking as blending compo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD13192010STANDARDTESTMETHODFORHYDROCARBONTYPESINLIQUIDPETROLEUMPRODUCTSBYFLUORESCENTINDICATORADSORPTION

链接地址:http://www.mydoc123.com/p-509626.html