ASTM C663-1998(2014) Standard Specification for Asbestos-Cement Storm Drain Pipe《石棉水泥排雨水管的标准规格》.pdf
《ASTM C663-1998(2014) Standard Specification for Asbestos-Cement Storm Drain Pipe《石棉水泥排雨水管的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C663-1998(2014) Standard Specification for Asbestos-Cement Storm Drain Pipe《石棉水泥排雨水管的标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C663 98 (Reapproved 2014)Standard Specification forAsbestos-Cement Storm Drain Pipe1This standard is issued under the fixed designation C663; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、 number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specification covers asbestos-cement pipe i
3、ntendedfor use in storm-water drainage of highways, airports, farms,foundations, and other similar drainage systems.1.2 The values stated in SI units are to be regarded as thestandard. The values stated in parentheses are for informationonly.1.3 WarningBreathing of asbestos dust is hazardous.Asbesto
4、s and asbestos products present demonstrated healthrisks for users and for those with whom they come into contact.In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For informa-tion on the safe use of chrysoltile asbestos, refer to “Safe Use
5、of Chrysotile Asbestos: A Manual on Preventive and ControlMeasures.”21.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the
6、applica-bility of regulatory limitations prior to use. See for a specifichazard warning.2. Referenced Documents2.1 ASTM Standards:3C150 Specification for Portland CementC458 Test Method for Organic Fiber Content of Asbestos-Cement ProductsC500 Test Methods for Asbestos-Cement PipeC595 Specification
7、for Blended Hydraulic CementsD2946 Terminology for Asbestos and AsbestosCementProducts2.2 Federal Standard:Fed. Std. No. 123 Marking for Shipment (Civil Agencies)42.3 Military Standard:MIL-STD-129 Marking for Shipment and Storage42.4 Other Standards:Uniform Freight Classification Rules5National Moto
8、r Freight Classification Rules63. Terminology3.1 Definitions:3.1.1 coupling, nin asbestos-cement conduit, sewer, un-derdrain and storm drain pipecomponent made from a largerdiameter pipe of the same type or class, or of Type II and ahigher class, or produced otherwise to yield at least equalperforma
9、nce, for joining asbestos-cement pipe that whenproperly installed, forms a silt-tight joint, allows alignmentcorrections and slight changes in direction, and provides anassembled joint equivalent in serviceability and strength to thepipe sections. Alternatively, for storm drain couplings, plasticsle
10、eves that, when properly installed develop sufficient tight-ness to prevent the surrounding soil from entering the drain,may be used as couplings.3.1.2 lot, nfor pipe sizes 525 mm (21 in.) in diameter andsmaller, each 300 lengths of pipe or less, of identical class andsized manufactured on each mach
11、ine during a 24-h period. Forpipe larger than 525 mm (21 in.), each 300 lengths of pipe orless, of identical class and size manufactured on each machineduring a period of consecutive working days not exceedingseven days.3.1.3 Additional terminology is given in TerminologyD2946.4. Classification4.1 T
12、he types of pipe shall be shown as Type I and Type IIcorresponding to the chemical requirements given in 10.1.1This specification is under the jurisdiction of ASTM Committee C17 onFiber-Reinforced Cement Products and is the direct responsibility of C17.03 onAsbestos - Cement Sheet Products and Acces
13、sories.Current edition approved Dec. 1, 2014. Published December 2014. Originallyapproved in 1970. Last previous edition approved in 2008 as C663 98 (2008).DOI: 10.1520/C0663-98R14.2Available from The Asbestos Institute, http:/ referenced ASTM standards, visit the ASTM website, www.astm.org, orconta
14、ct ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from Standardization Documents Order Desk, Bldg. 4, Section D,700 Robbins Ave., Philadelphia, PA 19111-5094 Attn: NPODS.5Availa
15、ble from the Uniform Classification Commission, Room 1106, 222 S.Riverside Plaza, Chicago, IL 60606.6Available from National Motor Freight Inc., 1616 P St. NW, Washington, DC20036.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.2 As
16、bestos-cement storm drain pipe furnished under thisspecification shall be designated as Class II, III, 2500D, IV, andV. The corresponding strength requirements are prescribed inTable 1. The D1load is the crushing test load expressed innewtons per linear metre per of diameter. (The D load is thecrush
17、ing test load expressed in pounds-force per linear ft per ftof diameter.) The pipe shall be furnished in 10, 15, 20, 25, 30,36, 38, 41, 46, 51, 53, 61, 69, 76, 84, 91, 99 and 107-cm sizes(4, 6, 8, 10, 12, 14, 15, 16, 18, 20, 21, 24, 27, 30, 33, 36, 39 and42-in. sizes).5. Materials and Manufacture5.1
18、 Asbestos-cement storm drain pipe shall be composed ofan intimate mixture of portland cement or portland blast-furnace slag cement meeting Specification C150 or portlandslag or pozzolan cements conforming to Specification C595.The mixture shall not contain more than 0.2 % of non-deleterious organic
19、components as determined by Test MethodC458. The material shall be of laminar construction formedunder pressure to a homogeneous structure and cured to meetthe physical and chemical requirements of this specification.6. Dimensions, Mass, and Permissible Variations6.1 The nominal length for asbestos-
20、cement storm drainpipe shall be either 3 or 4 m (10 or 13 ft).Amaximum of 15 %of the total footage of any one size and type for any order maybe furnished, at the manufacturers option, in pipe lengthsshorter than specified nominal, but not shorter than2m(7ft);these shall be termed random lengths.6.2
21、A tolerance of 25 mm (61 in.) shall apply to nominalstandard lengths. Random lengths shall be classified to 150 mm(+ 15025 mm) 6 in. (+ 4.91.0 in.) increments, allowing atolerance of 124 mm (+ 478 in.) and 1 in.6.3 The average inside diameter of the pipe may be less thanthe nominal size by not more
22、than 6 mm (0.25 in.) or 112 %,whichever is greater.7. Sampling7.1 All material tested under this specification shall be inair-dried condition in equilibrium with atmospheric moisture.7.2 For crushing tests, select one full length of pipe fromeach lot of each size, class, and type of pipe. Cut one te
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC66319982014STANDARDSPECIFICATIONFORASBESTOSCEMENTSTORMDRAINPIPE 石棉 水泥 雨水管 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-507950.html