ASTM C1688 C1688M-2013 Standard Test Method for Density and Void Content of Freshly Mixed Pervious Concrete《新拌透水混凝土密度和孔隙量的标准试验方法》.pdf
《ASTM C1688 C1688M-2013 Standard Test Method for Density and Void Content of Freshly Mixed Pervious Concrete《新拌透水混凝土密度和孔隙量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1688 C1688M-2013 Standard Test Method for Density and Void Content of Freshly Mixed Pervious Concrete《新拌透水混凝土密度和孔隙量的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1688/C1688M 12C1688/C1688M 13Standard Test Method forDensity and Void Content of Freshly Mixed PerviousConcrete1This standard is issued under the fixed designation C1688/C1688M; the number immediately following the designation indicates theyear of original adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This test method covers determining the density of freshly mixed pervious concrete under s
3、tandardized conditions and givesformulas for calculating the void content of pervious concrete. Test results are not intended to represent the in-place density andvoid content.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in
4、 eachsystem may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from thetwo systems may result in non-conformance with the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. I
5、t is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. (WarningFresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin andtissue upon prolonged expo
6、sure.2)1.4 The text of this test method references notes and footnotes that provide explanatory information. These notes and footnotes(excluding those in tables) shall not be considered as requirements of this test method.2. Referenced Documents2.1 ASTM Standards:3C29/C29M Test Method for Bulk Densi
7、ty (“Unit Weight”) and Voids in AggregateC125 Terminology Relating to Concrete and Concrete AggregatesC127 Test Method for Density, Relative Density (Specific Gravity), and Absorption of Coarse AggregateC128 Test Method for Density, Relative Density (Specific Gravity), and Absorption of Fine Aggrega
8、teC150/C150M Specification for Portland CementC172/C172M Practice for Sampling Freshly Mixed ConcreteC188 Test Method for Density of Hydraulic CementC192/C192M Practice for Making and Curing Concrete Test Specimens in the LaboratoryC231/C231M Test Method for Air Content of Freshly Mixed Concrete by
9、the Pressure MethodC311 Test Methods for Sampling and Testing Fly Ash or Natural Pozzolans for Use in Portland-Cement ConcreteC595/C595M Specification for Blended Hydraulic CementsC989/C989M Specification for Slag Cement for Use in Concrete and MortarsC1157/C1157M Performance Specification for Hydra
10、ulic CementC1240 Specification for Silica Fume Used in Cementitious MixturesD698 Test Methods for Laboratory Compaction Characteristics of Soil Using Standard Effort (12 400 ft-lbf/ft3 (600 kN-m/m3)3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this standard, refer to Terminolo
11、gy C125.1 This test method is under the jurisdiction of ASTM Committee C09 on Concrete and Concrete Aggregates and is the direct responsibility of Subcommittee C09.49 onPervious Concrete.Current edition approved Feb. 15, 2012Feb. 1, 2013. Published March 2012March 2013. Originally approved in 2008.
12、Last previous edition approved in 20112012 asC1688/C1688M11.12. DOI: 10.1520/C1688_C1688M-12.10.1520/C1688_C1688M-13.2 Section on Safety Precautions, Manual of Aggregate and Concrete Testing, Annual Book of ASTM Standards, Vol 04.02.3 For referencedASTM standards, visit theASTM website, www.astm.org
13、, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes
14、 have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official
15、 document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2 Definitions of Terms Specific to This Standard:3.2.1 concrete, pervious, nhydraulic cement concrete with di
16、stributed, interconnected macroscopic voids that allow water topass through the material with little resistance.C1688/C1688M 1323.3 Symbols:D = density (unit weight) of concrete kg/m3 lb/ft3Ms = total mass of all materials batched, kg lb (see Note 1)Mc = mass of the measure filled with concrete, kg
17、lbMm = mass of the measure, kg lbT = theoretical density of the concrete computed on an air-free basis, kg/m3 lb/ft3 (see Note 1)U = percentage of voids in the fresh pervious concrete, in-cluding entrained and entrapped air voids in the ce-ment paste.Vs = sum of the absolute volumes of the component
18、 ingredi-ents in the batch, m3 ft3Vm = volume of the measure, m3 ft3NOTE 1The theoretical density is a laboratory determination, and is assumed to remain constant for all batches made using identical componentingredients and proportions.4. Summary of Test Method4.1 A sample of fresh pervious concret
19、e is placed and consolidated in a standard measure. The concrete is consolidated usinga standard Proctor hammer. The density and void content of the pervious concrete are calculated based on the measured mass ofthe consolidated concrete specimen, the volume of the measure, and the total mass of mate
20、rials batched.5. Significance and Use5.1 This test method provides a procedure for determining the density and void content of freshly mixed pervious concrete.5.2 This test method is applicable to pervious concrete mixtures containing coarse aggregate with a nominal maximum size of25 mm 1 in. or sma
21、ller.5.3 The measured fresh density may be used as verification of mixture proportions.5.4 This method uses a standard consolidation procedure to measure fresh density and void content of a pervious concretemixture as delivered. Test results are not intended to represent the density and void content
22、 of the in-place pervious concrete. Thismethod shall not be used to determine the in-place void content or yield of the pervious concrete.6. Apparatus6.1 BalanceA balance or scale accurate to 50 g 0.1 lb or to within 0.3 % of the test load, whichever is greater, at any pointwithin the range of use.
23、The range of use shall be considered to extend from the mass of the empty measure to the mass of themeasure filled with concrete having an assumed density of 2600 kg/m3 160 lb/ft3.6.2 Standard Proctor HammerA device used to compact a pervious concrete specimen that conforms to Test Method D698.6.3 M
24、easureAcylindrical container made of steel or other suitable metal with a capacity of 7.0 6 0.6 L 0.25 6 0.02 ft3 anda diameter equal to 0.75 to 1.25 times the height (See Note 2). The volume of the measure shall be determined as described inTest Method C29/C29M. The top rim of the container shall b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1688C1688M2013STANDARDTESTMETHODFORDENSITYANDVOIDCONTENTOFFRESHLYMIXEDPERVIOUSCONCRETE 透水 混凝土 密度

链接地址:http://www.mydoc123.com/p-465526.html