ASTM C1601-2006 Standard Test Method for Field Determination of Water Penetration of Masonry Wall Surfaces《砖石墙表面水渗透性的现场测定的标准试验方法》.pdf
《ASTM C1601-2006 Standard Test Method for Field Determination of Water Penetration of Masonry Wall Surfaces《砖石墙表面水渗透性的现场测定的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1601-2006 Standard Test Method for Field Determination of Water Penetration of Masonry Wall Surfaces《砖石墙表面水渗透性的现场测定的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1601 06Standard Test Method forField Determination of Water Penetration of Masonry WallSurfaces1This standard is issued under the fixed designation C 1601; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the field determination of waterpenetration of a masonry wall surface under specific water f
3、lowrate and air pressure conditions. This test is intended for use onany masonry wall surface that can be properly instrumentedand tested within the requirements of this standard.1.2 This test method is not identical to and the results arenot directly comparable with the laboratory standard TestMeth
4、od E 514 “Test Method for Water Penetration and Leak-age Through Masonry.”1.3 Surface penetration, as determined by this test method,is defined as the amount of water passing through the wallsurface exposed to testing per unit time per unit area. Thisproperty is not directly comparable to overall wa
5、ter penetrationand leakage, which are typically defined as the amount of watertravelling completely through a masonry system.1.4 This standard may involve hazardous materials, opera-tions, or equipment. This standard does not purport to addressall of the safety problems associated with its use. It i
6、s theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 1232 Terminology of MasonryE 514 Test Method for Water Penetration and LeakageTh
7、rough Masonry3. Terminology3.1 For definitions of terms used in this test method, refer toTerminology C 1232.4. Significance and Use4.1 This non-destructive test method contains proceduresand equipment requirements to quantitatively determine thesurface penetration of water at a single location on a
8、 masonrywall. It is not designed to determine the overall water penetra-tion and leakage of a masonry system.4.2 Excessive water penetration of masonry may degrademasonry wall performance with respect to thermal conductiv-ity, durability, efflorescence, staining, corrosion of embeddedmetal items, an
9、d water leakage.4.3 This test may be used to evaluate masonry walls in-situor for field mock-up testing. Common applications of thismethod have been comparison of water penetration rates ofwalls before and after repairs, and testing the efficacy ofcoatings. Alternative procedures are also provided t
10、o simulatethe effect of local climatology on water penetration of masonrywall surfaces.4.4 The outer surface of all masonry walls will experiencewater penetration when subjected to wind-driven rain. Theresistance to water penetration is dependent on materials,workmanship, design, and maintenance. So
11、me wall typesaccommodate large volumes of water penetration, withoutdeleterious effects, through the presence of properly designedand installed drainage systems including flashing and weepholes. Use of this standard without consideration of the overallwall system may lead to incorrect conclusions re
12、gardingperformance.4.5 It is the intent of this standard that a sheet of water bedeveloped and maintained on the wall surface during testing. Insome cases, due to the surface texture of the masonry, theapplication of a coating, or other factors, a sheet of water willnot consistently form. In those c
13、ases, results of this test methodwill likely be inaccurate.1This Test Method is under the jurisdiction of ASTM Committee C15 onManufactured Masonry Units and is the direct responsibility of SubcommitteeC15.04 on Research.Current edition approved July 1, 2006. Published July 2006. Originally approved
14、in 2004. Last previous edition approved in 2005 as C 1601 05.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.
15、1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.6 This test method is similar to but distinct from thelaboratory Test Method E 514. This field test method isdesigned
16、 to test in-situ walls. E 514 laboratory test method isdesigned to test laboratory wall specimens. This test methoddetermines water penetration of the masonry at its surface. TestMethod E 514 measures the water that has penetrated into andthrough the masonry specimen and is collected. Direct com-par
17、ison of results from this test method and Test Method E 514are inappropriate.5. Apparatus5.1 Test ChamberUse a test chamber similar to thatshown in Fig. 1. Provide a rectangular opening with aminimum area of 12 ft2(1.08 m2) with a minimum dimensionof 24 in. (0.6 m) for each side of the opening (Note
18、 1). Seal thecontact surface between the frame of the chamber and the testarea to prevent loss of water and maintain air pressure. Coverthe face of the chamber with a tough, transparent materialcapable of withstanding the test pressure (Note 2). Provide a34-in. (19-mm) diameter, corrosion-resistant,
19、 water spray pipewith a single line of 0.04-in. (1.0-mm) diameter holes spaced 1in. (25 mm) apart, starting within 1 in. (25 mm) of each end(Note 3). Position the water spray pipe within the chamber sothat the water impinges the wall perpendicular to the wall notmore than 1.5 in. (40 mm) below the i
20、nterior top of the testchamber.NOTE 1A size of 36 in. (0.9 m) wide and 48 in. (1.2 m) high iscommon.NOTE 2Transparent plastic sheets316 to14 inch (5 to 6 mm) thickhave been shown to perform well. Plexiglast and Lexant are twoproducts that have been used.NOTE 3Clean-outs at the end of the spray bar t
21、o facilitate cleaning thespray bar are common.5.2 Fixtures and Appurtenances to ChamberFixtures andappurtenances to the chamber include an air line with manom-eter or pressure gauge able to read air pressure to within 0.50lb/ft2(24 Pa), a water line with valves, a flow meter in thewater supply line
22、able to read flow within 0.02 gpm (4.5 L/h),and a water drain pipe at the bottom of the chamber. The wateris stored in a calibrated reservoir with a minimum volume of 3gal. (13 L), with graduations to allow readings within 0.015 gal(0.055 L) (Note 4). Pump water from the reservoir to the spraybar. R
23、eturn water which drains from the bottom of the chamberdirectly to the reservoir.NOTE 4Use of a cylindrical reservoir having dimensions of approxi-mately 4 to 8 inches (100 to 200 mm) in diameter by 5 ft. (1.5 m) or talleris common.5.3 Other equipment includes devices for handling andmounting the ch
24、amber and measuring time, water quantities,and ambient temperature.6. Hazards6.1 The use of this test method requires careful design ofboth air chamber and support of the wall system to avoidpossible injury due to equipment or masonry failure. Assurethat the chamber and its attachment to the wall ar
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16012006STANDARDTESTMETHODFORFIELDDETERMINATIONOFWATERPENETRATIONOFMASONRYWALLSURFACES 砖石 表面 渗透性

链接地址:http://www.mydoc123.com/p-465256.html