ASTM B890-2007(2012) Standard Test Method for Determination of Metallic Constituents of Tungsten Alloys and Tungsten Hardmetals by X-Ray Fluorescence Spectrometry《X射线荧光光谱法测定钨合金和钨硬金.pdf
《ASTM B890-2007(2012) Standard Test Method for Determination of Metallic Constituents of Tungsten Alloys and Tungsten Hardmetals by X-Ray Fluorescence Spectrometry《X射线荧光光谱法测定钨合金和钨硬金.pdf》由会员分享,可在线阅读,更多相关《ASTM B890-2007(2012) Standard Test Method for Determination of Metallic Constituents of Tungsten Alloys and Tungsten Hardmetals by X-Ray Fluorescence Spectrometry《X射线荧光光谱法测定钨合金和钨硬金.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B890 07 (Reapproved 2012)Standard Test Method forDetermination of Metallic Constituents of Tungsten Alloysand Tungsten Hardmetals by X-Ray FluorescenceSpectrometry1This standard is issued under the fixed designation B890; the number immediately following the designation indicates the ye
2、ar oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes a procedure for the determi
3、-nation of the concentration, generally reported as mass percent,of the metallic constituents of tungsten-based alloys andhardmetals utilizing wavelength dispersive X-ray fluorescencespectrometry (XRF). This test method incorporates the prepa-ration of standards using reagent grade metallic oxides,l
4、ithium-borate compounds, and fusion techniques. This testmethod details techniques for preparing representative speci-mens of both powder and sintered tungsten-based material.This test method is accurate for a wide range of compositions,and can be used for acceptance of material to grade specifica-t
5、ions.1.2 This test method is applicable to mixtures of tungsten ortungsten carbide with additions of refractory metal carbidesand binder metals. Table 1 lists the most common elementalconstituents and their concentration range. Note that many ofthese occur as metallic carbides.1.3 This standard does
6、 not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Stand
7、ards:2E135 Terminology Relating to Analytical Chemistry forMetals, Ores, and Related MaterialsE1361 Guide for Correction of Interelement Effects inX-Ray Spectrometric Analysis2.2 Handbook of Chemistry and Physics,367th ed3. Terminology3.1 For definitions of terms used in this test method, refer toTe
8、rminology E135.4. Summary of Test Method4.1 A suite of standards which closely match the chemicalcontent of the material to be analyzed are prepared usingreagent grade metallic oxides. Test samples are oxidized in ahigh-temperature furnace open to air. Fused glass specimensare prepared for these sta
9、ndards and for the test samples to beanalyzed. These specimens of oxidized tungsten or tungstencarbide alloys are irradiated with an energetic primary X-raybeam. The intensity of the resultant secondary X-rays, charac-teristic in energy, for each elemental constituent is measured bymeans of a suitab
10、le detector or combination of detectors afterdiffraction by a Bragg spectrometer. The concentration of eachconstituent element is calculated by comparison with standardsamples which closely match the chemical content of theanalyzed material. The calculation may be manual, incorporatea calibration cu
11、rve, or be performed by a computer programwhich incorporates correction routines for X-ray absorptionand enhancement effects (see Guide E1361).5. Significance and Use5.1 This test method allows the determination of the chemi-cal composition of powdered and sintered tungsten-basedhardmetals. This tes
12、t method is not applicable to materialwhich will not oxidize readily at high temperatures in air, suchas tungsten/copper or tungsten/silver alloys.5.2 This test method specified lithium-borate compoundsfor the glass fusion material. However, numerous other choicesare available. These include other l
13、ithium-borate compounds,sodium carbonate and borate mixtures, and others. The meth-odology specified here is still applicable as long as the samefusion mixture is used for both standards and specimens.1This test method is under the jurisdiction of ASTM Committee B09 on MetalPowders and Metal Powder
14、Productsand is the direct responsibility of Subcommit-tee B09.06 on Cemented Carbides.Current edition approved October 1, 2012. Published October 2012. Originallyapproved in 1998. Last previous edition approved in 2007 as B890 07. DOI:10.1520/B0890-07R12.2For referenced ASTM standards, visit the AST
15、M website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3CRC Press, Boca Raton, FL, 1987.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Co
16、nshohocken, PA 19428-2959. United States16. Interferences6.1 Errors in XRF-determined compositional values may beencountered due to X-ray enhancement and absorption effectsdependent on the elements present and the X-ray line beingmeasured for a specific element. This effect can be reduced bydetermin
17、ation of correction factors using appropriate standardsand interelement correction routines, manual or computerized.6.2 Accuracy and precision of the analytical results obtainedfrom molybdenum-containing samples may be rendered unre-liable due to the sublimation and evaporation of molybdenumfrom the
18、 material during the oxidation step in specimenpreparation.6.3 Incorporation of the fusion method of specimen prepa-ration will:6.3.1 Reduce the deleterious influence of particle size ef-fects experienced when analyzing powder materials by varyingparticle size.6.3.2 Reduce inhomogenieties within a s
19、ample.6.3.3 Improve penetration of X rays.6.3.4 Reduce interelement interferences by tungsten on allother elements.7. Apparatus7.1 X-Ray Fluorescence Wavelength Dispersive Spectrom-eter7.2 FluxerAn automated high-temperature mixing devicecapable of melting, mixing, and pouring a molten liquidspecime
20、n into a proper casting dish, is highly preferred7.3 Analytical Balance, readability of 0.00001 g7.4 Toploading Balance, readability of 0.001 g7.5 Ordinary Laboratory Apparatus .7.6 One Pt - 5 % Au Casting Dish (minimum)7.7 One Pt - 5 % Au Crucible (minimum)7.8 Platinum Tipped Tongs7.9 Weighing Pape
21、r7.10 Chemical Spoon and Scoopula7.11 Ceramic Combustion Boat7.12 High Temperature Tube or Muffle Furnace, open to theatmosphere7.13 Self-adhering Stickers,34 by 1 in.7.14 High-Temperature marking pen7.15 Ceramic Mortar and Pestle7.16 Tungsten Carbide Mortar and Pestle7.17 Miniature Mixer, optional8
22、. Reagents and Materials8.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents conform to the specification of the Committee onAnalytical Reagents of the American Chemical Society wheresuch specifications are available.4Ot
23、her grades may be used,provided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.8.2 Di-lithiumtetraborate (Li2B4O7):Lithiummetaborate(LiBO2), 66 + 34.8.3 Lithium Bromide (LiBr).8.4 Metallic Oxide Powder, high
24、est oxidation state forelements of interest; that is Co3O4,Cr2O3,Fe3O4, HfO2,MoO3,Nb2O5, NiO, Ta2O5,TiO2,V2O5, and WO3WarningSeveral of the metallic oxides used in this testmethod are highly toxic and possibly carcinogenic, such asCr2O3, NiO, or V2O5. Extreme care should be used at all timeswhen han
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB89020072012STANDARDTESTMETHODFORDETERMINATIONOFMETALLICCONSTITUENTSOFTUNGSTENALLOYSANDTUNGSTENHARDMETALSBYXRAYFLUORESCENCESPECTROMETRYX

链接地址:http://www.mydoc123.com/p-462661.html