ASTM B173-2001a(2007)e1 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members for Electrical Conductors《电导线用同芯绞绳铜导线标准规范》.pdf
《ASTM B173-2001a(2007)e1 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members for Electrical Conductors《电导线用同芯绞绳铜导线标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM B173-2001a(2007)e1 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members for Electrical Conductors《电导线用同芯绞绳铜导线标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B 173 01a (Reapproved 2007)e1Standard Specification forRope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members, for Electrical Conductors1This standard is issued under the fixed designation B 173; the number immediately following the designation indicates the year oforigi
2、nal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of De
3、fense.e1NOTETable 1 was editorially corrected in March 2007.1. Scope1.1 This specification covers bare rope-lay-stranded con-ductors having concentric-stranded members made from roundcopper wires, either uncoated or coated with tin, lead, orlead-alloy for use as electrical conductors (Explanatory No
4、te 1and Note 2).1.2 Coated wires shall include only those wires with fin-ished diameters and densities substantially equal to the respec-tive diameters and densities of uncoated wires.1.3 The values stated in inch-pound or SI units are to beregarded separately as standard. Each system shall be usedi
5、ndependently of the other. Combining values from the twosystems may result in nonconformance with the specification.For conductor sizes designated by AWG or kcmil, the require-ments in SI units have been numerically converted fromcorresponding values, stated or derived, in inch-pound units.For condu
6、ctor sizes designated by SI units only, the require-ments are stated or derived in SI units.1.3.1 For density, resistivity, and temperature, the valuesstated in SI units are to be regarded as standard.2. Referenced Documents2.1 The following documents of the issue in effect at thetime of reference f
7、orm a part of this specification to the extentreferenced herein:2.2 ASTM Standards:2B3 Specification for Soft or Annealed Copper WireB8 Specification for Concentric-Lay-Stranded CopperConductors, Hard, Medium-Hard, or SoftB33 Specification for Tinned Soft or Annealed CopperWire for Electrical Purpos
8、esB 172 Specification for Rope-Lay-Stranded Copper Con-ductors Having Bunch-Stranded Members, for ElectricalConductorsB 189 Specification for Lead-Coated and Lead-Alloy-Coated Soft Copper Wire for Electrical PurposesB 263 Test Method for Determination of Cross-SectionalArea of Stranded ConductorsB 3
9、54 Terminology Relating to Uninsulated Metallic Elec-trical Conductors2.3 American National Standard:ANSI C42.35 Definitions of Electrical Terms33. Classification3.1 For the purpose of this specification rope-lay-strandedconductors having concentric-stranded members are classifiedas follows:3.1.1 Cl
10、ass GConductors consisting of 7 to 61 rope-lay-stranded members, each of which consists of 7 to 19concentric-stranded wires, with total conductor sizes rangingfrom No. 14 AWG (2.08 mm2) to 5 000 000 cmil (2534 mm2).(Typical use is for rubber-sheathed conductor, apparatus con-ductor, portable conduct
11、or, and similar applications.)3.1.2 Class HConductors consisting of 19 to 91 rope-lay-stranded members, each of which consists of 7 to 19concentric-stranded wires, with total conductor sizes rangingfrom No. 9 AWG (6.63 mm2) to 5 000 000 cmil (2534 mm2).Class K construction produces a conductor with
12、greater flex-ibility than class G. (Typical use is for rubber-sheathed cordand applications where flexibility is required such as ontake-up reels over sheaves and extra-flexible apparatus con-ductor.)4. Ordering Information4.1 Orders for material under this specification shall includethe following i
13、nformation:4.1.1 Quantity of each size and class;1This specification is under the jurisdiction of ASTM Committee B01 onElectrical Conductors and is the direct responsibility of Subcommittee B01.04 onConductors of Copper and Copper Alloys.Current edition approved March 15, 2007. Published April 2007.
14、 Originallyapproved in 1942 to replace portions of B 158 41 T. Last previous editionapproved in 2001 as B 173 01a.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to th
15、e standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.1.2
16、 Conductor size: circular-mil area or AWG (Section 7);4.1.3 Class (Section 3 and Table 1);4.1.4 Whether coated or uncoated; if coated, designate typeof coating (see 11.1);4.1.5 Details of special-purpose lays, if required (see 6.2and 6.3) and (Explanatory Note 3);4.1.6 Package size (see 14.1);4.1.7
17、Special package marking, if required (Section 15);4.1.8 Lagging, if required (see 14.2); and4.1.9 Place of inspection (Section 13).5. Joints5.1 Necessary joints in wires or in groups of wires shall bemade in accordance with accepted commerical practice, takinginto account the size of the wire or gro
18、up of wires as related tothe size of the entire conductor.TABLE 1 Construction Requirements of Rope-Lay Stranded Copper Conductors Having Concentric-Stranded MembersAArea of CrossSectionSizeAWGClass G Class HNumberofWiresDiameter ofWiresNumberofWiresin EachMemberCompleted ConductorBNumberof WiresDia
19、meter ofWiresNumberofWiresin EachMemberCompleted ConductorBNominalDiameterNominalMassNominalDiameterNominalMasscmil mm2 in. mm in. mmlb/1000 ftkg/km in. mm in. mmlb/1000 ftkg/km5 000 000 2534 . . . 1159 0.0657 1.67 19 2.957 75.1 16 052 23 888 1729 0.0538 1.37 19 2.959 75.2 16 057 23 8964 500 000 228
20、0 . . . 1159 0.0623 1.58 19 2.804 71.2 14 433 21 479 1729 0.0510 1.30 19 2.805 71.2 14 429 21 4734 000 000 2027 . . . 1159 0.0587 1.49 19 2.642 67.1 12 814 19 069 1729 0.0481 1.22 19 2.646 67.2 12 835 19 1013 500 000 1773 . . . 1159 0.0550 1.40 19 2.475 62.9 11 249 16 741 1729 0.0450 1.14 19 2.475 6
21、2.9 11 234 16 7183 000 000 1520 . . . 1159 0.0509 1.29 19 2.291 58.2 9635 14 338 1729 0.0417 1.06 19 2.294 58.3 9647 14 3562 500 000 1267 . . . 703 0.0596 1.51 19 2.086 53.0 8012 11 924 1159 0.0464 1.18 19 2.088 53.0 8006 11 9152 000 000 1013 . . . 703 0.0533 1.35 19 1.866 47.4 6408 9536 1159 0.0415
22、 1.05 19 1.868 47.4 6405 95311 900 000 963 . . . 703 0.0520 1.32 19 1.820 46.2 6099 9077 1159 0.0405 1.03 19 1.823 46.3 6100 90771 800 000 912 . . . 703 0.0506 1.29 19 1.771 45.0 5775 8594 1159 0.0394 1.00 19 1.773 45.0 5773 85911 750 000 887 . . . 703 0.0499 1.27 19 1.747 44.4 5617 8358 1159 0.0389
23、 0.99 19 1.751 44.5 5627 83741 700 000 861 . . . 703 0.0492 1.25 19 1.722 43.7 5460 8125 1159 0.0383 0.97 19 1.724 43.8 5455 81181 600 000 811 . . . 703 0.0477 1.21 19 1.670 42.4 5132 7638 1159 0.0372 0.94 19 1.674 42.5 5146 76581 500 000 760 . . . 427 0.0593 1.51 7 1.601 40.7 4772 7102 703 0.0462 1
24、.17 19 1.617 41.1 4815 71651 400 000 709 . . . 427 0.0573 1.46 7 1.547 39.3 4456 6631 703 0.0446 1.13 19 1.561 39.6 4487 66771 300 000 659 . . . 427 0.0552 1.40 7 1.490 37.8 4135 6154 703 0.0430 1.09 19 1.505 38.2 4171 62071 250 000 633 . . . 427 0.0541 1.37 7 1.461 37.1 3972 5911 703 0.0422 1.07 19
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB1732001A2007E1STANDARDSPECIFICATIONFORROPELAYSTRANDEDCOPPERCONDUCTORSHAVINGCONCENTRICSTRANDEDMEMBERSFORELECTRICALCONDUCTORS

链接地址:http://www.mydoc123.com/p-460526.html