ANSI ASTM C1039-1985 Standard Test Methods for Apparent Porosity Apparent Specific Gravity and Bulk Density of Graphite Electrodes.pdf
《ANSI ASTM C1039-1985 Standard Test Methods for Apparent Porosity Apparent Specific Gravity and Bulk Density of Graphite Electrodes.pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM C1039-1985 Standard Test Methods for Apparent Porosity Apparent Specific Gravity and Bulk Density of Graphite Electrodes.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1039 85 (Reapproved 2015) An American National StandardStandard Test Methods forApparent Porosity, Apparent Specific Gravity, and BulkDensity of Graphite Electrodes1This standard is issued under the fixed designation C1039; the number immediately following the designation indicates the
2、 year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the determination of appar
3、entporosity, apparent specific gravity, and bulk density of corestaken from graphite electrodes manufactured for use in electricarc furnaces. (See also C559 and C838.)1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This
4、standard does not purport to address the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Sta
5、ndards:2C559 Test Method for Bulk Density by Physical Measure-ments of Manufactured Carbon and Graphite ArticlesC783 Practice for Core Sampling of Graphite ElectrodesC838 Test Method for Bulk Density of As-ManufacturedCarbon and Graphite Shapes3. Significance and Use3.1 The results of these test met
6、hods can be used as a qualitycontrol or quality assurance check of electrodes either duringtheir manufacture or at the users location. The results of thesemethods tend to be operator-sensitive, therefore, care must betaken in the execution of the test in order to obtain reproducibleresults.4. Appara
7、tus4.1 Drying Oven.4.2 Analytical Balance, capable of weighing to 0.1 g.4.3 Autoclave or Pressure Vessel, capable of withstandingone atmosphere externally and designed to withstand at least448 kPa to 483 kPa internal pressure.4.3.1 The pressure vessel shall be provided with an opentopcontainer to ho
8、ld the specimens and a means of introducingwater around the specimens while specimens are being held atlow pressure.4.4 Vacuum Pump.4.5 Wire Loop, Halter or Stirrup, fabricated with 22 AWG(9.643 mm) copper wire shall be provided for determiningsuspended weight.4.6 Smooth Linen or Cotton Cloth.5. Tes
9、t Specimens and Sampling5.1 Electrodes can be sampled using Practice C783 thatresult in a specimen with approximately 50 mm diameter and191 mm long or a specimen of equivalent volume.5.2 If sizes and shapes which are different from thosedescribed in 5.1, these shall be included in the report.5.3 For
10、 each test, select at least five electrodes, at random,to represent a lot. The lot size will be determined by agreementof the parties desiring the tests.6. Calibration6.1 Prior to obtaining the suspended weights of thespecimens, the balance shall be adjusted to zero with the wirestirrup suspended fr
11、om the balance and immersed into acontainer of the liquid to the same depth in the liquid as occurswhen a specimen is in place.7. Procedure7.1 Determinations of Dry Weight, D:7.1.1 Dry the test specimens to constant weight by heatingto 100 C to 110 C. Cool and determine the dry weight, D,ingrams to
12、the nearest 0.1 g. If the time between drying andweighing exceeds 8 h, the specimens must be stored in adesiccator.7.1.2 The determination of dry weight may be done eitherbefore or after the saturation operation. If the specimen isfriable or there is evidence that particles have broken looseduring t
13、he saturation operation, the dry weight shall be1These test methods are under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.F0 on Manufactured Carbon and Graphite Products.Current edition approved Oct. 1,
14、 2015. Published December 2015. Originallyapproved in 1985. Last previous edition approved in 2010 as C1039 85 (2010)1.DOI: 10.1520/C1039-85R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards v
15、olume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1obtained after the suspended and saturated weights have beendetermined. Drying as described in 7.1.1 mu
16、st be carried out.7.2 Saturation:7.2.1 Using the pressure vessel described in 4.3, place thespecimens in the open-top container inside the vessel. Closeand seal the vessel and pump down at least to 133 Pa (1 mmHg) and maintain this pressure for 30 min.7.2.2 Slowly introduce water (preferably distill
17、ed water)until the specimens are covered with at least 40 mm of water.Continue to pump for an additional 5 min.NOTE 1Sufficient water must be provided above the specimens tosupply enough water to fill the open pores of the specimens duringpressurization. If after pressurization, one or more specimen
18、s are exposedto air above the water, these specimens must be dried and process repeated(7.1.1).7.2.3 After the evacuation process is completed, close thevacuum line and introduce air pressure. Pressurize to 207 kPa6 7 kPa gauge pressure and hold for 4 h. Following this periodof time return the vesse
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMC10391985STANDARDTESTMETHODSFORAPPARENTPOROSITYAPPARENTSPECIFICGRAVITYANDBULKDENSITYOFGRAPHITEELECTRODESPDF

链接地址:http://www.mydoc123.com/p-432204.html