NAVY UFGS-07 42 13-2011 METAL WALL PANELS《金属墙面板》.pdf
《NAVY UFGS-07 42 13-2011 METAL WALL PANELS《金属墙面板》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-07 42 13-2011 METAL WALL PANELS《金属墙面板》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-07 42 13 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-07 42 13 (November 2010)UFGS-07 42 13 (January 2008)UFGS-07 40 00.00 40 (July 2007)UFGS-07 42 13 (April 2006)UFGS-07 46 19.00 40 (July 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agr
2、eement with UMRL dated April 2011*SECTION TABLE OF CONTENTSDIVISION 07 - THERMAL AND MOISTURE PROTECTIONSECTION 07 42 13METAL WALL PANELS05/11PART 1 GENERAL1.1 REFERENCES1.2 DEFINITIONS1.3 DESCRIPTION OF WALL PANEL SYSTEM1.3.1 Metal Wall Panel General Performance1.3.2 Structural Performance1.3.3 Air
3、 Infiltration1.3.4 Water Penetration Under Static Pressure1.3.5 Water Penetration Under Dynamic Pressure1.4 SUBMITTALS1.5 QUALITY ASSURANCE1.5.1 Pre-Installation Conference1.5.1.1 Installation Drawings1.5.1.2 Wind Load Design Analysis1.5.2 Manufacturers Technical Representative1.5.3 Qualification of
4、 Manufacturer1.5.3.1 Manufacturers Certificates1.5.4 Certified Qualification of Installation Contractor1.5.4.1 Qualifications for Welding Work1.5.5 Single Source1.5.6 Manufacturers Maintenance Instructions1.6 DELIVERY, HANDLING, AND STORAGE1.7 PROJECT CONDITIONS1.7.1 Field Measurements1.7.2 Weather
5、Limitations1.8 WARRANTY1.8.1 20 Year “No Dollar Limit“ Warranty for Labor and MaterialPART 2 PRODUCTS2.1 FABRICATIONSECTION 07 42 13 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.1.1 Sheet Metal Accessories2.2 PANEL MATERIALS2.2.1 Aluminum
6、Sheet2.2.2 Steel Sheet2.2.3 Factory Color Finish2.2.3.1 Metal Preparation2.2.3.2 Prime Coating2.2.3.3 Exterior Finish Coating2.2.3.4 Interior Finish Coating2.2.3.5 Color2.2.3.6 Physical Properties2.3 MISCELLANEOUS METAL FRAMING2.3.1 Fasteners for Miscellaneous Metal Framing2.4 FASTENERS2.4.1 General
7、2.4.1.1 Exposed Fasteners2.4.1.2 Hidden Fasteners2.4.1.3 Screws2.4.1.4 Rivets2.4.1.5 Attachment Clips2.5 ACCESSORIES2.5.1 General2.5.2 Rubber Closure Strips2.5.3 Metal Closure Strips2.5.4 Joint Sealants2.5.4.1 Sealants and Caulking2.5.4.2 Shop-Applied2.5.4.3 Field-Applied2.5.4.4 Pressure Sensitive T
8、ape2.6 SHEET METAL FLASHING AND TRIM2.6.1 Fabrication2.7 REPAIR OF FINISH PROTECTIONPART 3 EXECUTION3.1 EXAMINATION3.2 PREPARATION3.3 WALL PANEL INSTALLATION3.3.1 Steel Wall Panels3.3.2 Aluminum Wall Panels3.3.3 Anchor Clips3.3.4 Metal Protection3.3.5 Joint Sealers3.4 FASTENER INSTALLATION3.5 FLASHI
9、NG, TRIM AND CLOSURE INSTALLATION3.5.1 General Requirements3.5.2 Metal Flashing3.5.3 Closures3.6 WORKMANSHIP3.7 ACCEPTANCE PROVISIONS3.7.1 Erection Tolerances3.7.2 Leakage Tests3.7.3 Repairs to Finish3.7.4 Paint-Finish Metal Siding3.8 FIELD QUALITY CONTROL3.8.1 Construction Monitoring3.9 CLEAN-UP AN
10、D DISPOSAL- End of Section Table of Contents -SECTION 07 42 13 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SECTION 07 42 13 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAV
11、FAC / AFCESA / NASA UFGS-07 42 13 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-07 42 13 (November 2010)UFGS-07 42 13 (January 2008)UFGS-07 40 00.00 40 (July 2007)UFGS-07 42 13 (April 2006)UFGS-07 46 19.00 40 (July 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with
12、UMRL dated April 2011*SECTION 07 42 13METAL WALL PANELS05/11*NOTE: This guide specification covers the requirements for both factory color and mill finish aluminum or steel non-structural metal wall panels.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when edi
13、ting this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements
14、not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: This section does not include light gage siding for temporary construction,
15、 housing, or pre-engineered metal buildings, or decorative wall panels.Coordinate this section with other system components specifications such as framing, insulation and sheet metal flashing. Also coordinate with applicable Unified Facilities Criteria as it relates to the specific project.*SECTION
16、07 42 13 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic desi
17、gnation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check R
18、eference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent
19、referenced. The publications are referred to within the text by the basic designation only.ALUMINUM ASSOCIATION (AA)AA ADM-105 (2005; Errata 2005) Aluminum Design ManualAA ASD1 (2009) Aluminum Standards and DataAMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)AAMA 501.1 (2005) Standard Test Me
20、thod for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic PressureAAMA 800 (2010) Voluntary Specifications and Test Methods for SealantsAMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)ANSI/AISC 341 (2005; Suppl No. 1 2005) Seismic Provisions for Structural Steel BuildingsAMERICAN I
21、RON AND STEEL INSTITUTE (AISI)AISI S100 (2007; Supplement 1) North American Specification for the Design of Cold-Formed Steel Structural MembersAISI SG03-3 (2002; Suppl 2001-2004; R 2008) Cold-Formed Steel Design Manual SetSECTION 07 42 13 Page 5Provided by IHSNot for ResaleNo reproduction or networ
22、king permitted without license from IHS-,-,-AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)ASCE 7-10 (2010) Minimum Design Loads for Buildings and Other StructuresAMERICAN WELDING SOCIETY (AWS)AWS A5.1/A5.1M (2004) Specification for Carbon Steel Electrodes for Shielded Metal Arc WeldingAWS D1.1/D1.1M (20
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS0742132011METALWALLPANELS 金属 墙面 PDF

链接地址:http://www.mydoc123.com/p-984725.html