NAVY MIL-R-7885 D (2)-1996 RIVETS BLIND STRUCTURAL MECHANICALLY LOCKED SPINDLE AND FRICTION LOCKED SPINDLE GENERAL SPECIFICATION FOR [Use In Lieu Of NAVY MIL-R-007885 C (1)]《机械锁主轴和.pdf
《NAVY MIL-R-7885 D (2)-1996 RIVETS BLIND STRUCTURAL MECHANICALLY LOCKED SPINDLE AND FRICTION LOCKED SPINDLE GENERAL SPECIFICATION FOR [Use In Lieu Of NAVY MIL-R-007885 C (1)]《机械锁主轴和.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-R-7885 D (2)-1996 RIVETS BLIND STRUCTURAL MECHANICALLY LOCKED SPINDLE AND FRICTION LOCKED SPINDLE GENERAL SPECIFICATION FOR [Use In Lieu Of NAVY MIL-R-007885 C (1)]《机械锁主轴和.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、I INCH-POUND 1 MIL-R-7885D AMENDm2 27 brill996 I SUPERSEDING AMENDMENT1 31 MARCH 1994 DETAIL SPECIFICATION RIVETS, BLIND, STRUCTURAL, MECHANICALLY LOCKED SPINDLE AND FRICTION LOCKED SPINDLE, GENERAL SPECIFICATION FOR This amendment forms a part of MIL-R-7885D, dated 18 Apd 1988, and is approved for
2、use by all Departments and Agencies of the Department of Defense. PAGE 1 1.2: Change Qpe I to read as follows: Type I - Mechanically locked spindle rivets Style A - Nominal diameter series Class 1 - Universal head rivets Class 2 - 100” Flush head rivets Class 3 - 100” Flush Shear head rivets CS 4 -
3、N/A Style B - Oversize diameter (1/64 inch) series (For repair use only; see 6.1) Class 1 - Universal head rivets Class 2 - 100” Flush head rivets Class 3 - N/A Class 4 - Flanged Dome head rivets DD Form 1426 note: Change the name and the address of the Preparing Activity to the following: “Naval Ai
4、r Systems Command (NAVAIR), (AIR-53033G), Washington, DC. 20361-5300.” AMSC N/A 1 Of4 DISTRlBUTION STATEMENT A: Approved for public release; distribution is unlimited. FSC 5320 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R-7885D Amendment 2 P
5、AGE 2 Under Military Specifications, delete the reference to MIL-S-5059 and substime with: “MIL-T-9046 - Titanium and Titanium alloy, sheet, strip and plate.” Under Military Specifications, delete the reference to MIL-A-8625. Under Federal Standards, delete the reference to FED-STD-151. Page 3 Mer 2
6、.2, Remove the reference to AMs 4906. Insert the following before 2.3: American Society for Testing and Materials (ASTM) B 117 Method of Salt Spray (Fog) Testing (Application for copies should be addressed to the Ameriqan Society for Testing and Materials, 1916 Race Street, Philadelphia, PA19103-118
7、7) PAGE 5 .“ ,. 3.7.2: After the first comma in the first sentence insert the following words: “always keeping the rivet head pressed against the coupon forming a blind head .” PAGE 9 4.6.4: Add the following sentence: “Rivets shall be tested at m. grip in coupons of 112 G thickness where G = Max. G
8、rip. Spacers may be installed on the blind side for rivet grips greater than those listed in Table III.7 4.6.4 and 4.6.5: Add the following sentence: “The load rate shall not exceed 110,000 pounds per minute per square inch of fastener cross sectional area up to the approximate yield load after whic
9、h it may be increased.” PAGE 11 Paragraphs 4.6.13 and 4.6.13.1, replace the words “Method 811 of FED-STD-151” with “ASTM B 117”. PAGE 14 Paragraph 4.7.9, replace the words “Method 811 of FED-STD-151” with “ASTM B 117”. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without li
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILR7885D21996RIVETSBLINDSTRUCTURALMECHANICALLYLOCKEDSPINDLEANDFRICTIONLOCKEDSPINDLEGENERALSPECIFICATIONFORUSEINLIEUOFNAVYMILR007885C1

链接地址:http://www.mydoc123.com/p-981324.html