ISA 61241-0-2006 Electrical Apparatus for Use in Zone 20 Zone 21 and Zone 22 Hazardous (Classified) Locations - General Requirements (12 10 02)《用于专区20 专区21和专区22危险(分类)场所的电气设备 一般要求 1.pdf
《ISA 61241-0-2006 Electrical Apparatus for Use in Zone 20 Zone 21 and Zone 22 Hazardous (Classified) Locations - General Requirements (12 10 02)《用于专区20 专区21和专区22危险(分类)场所的电气设备 一般要求 1.pdf》由会员分享,可在线阅读,更多相关《ISA 61241-0-2006 Electrical Apparatus for Use in Zone 20 Zone 21 and Zone 22 Hazardous (Classified) Locations - General Requirements (12 10 02)《用于专区20 专区21和专区22危险(分类)场所的电气设备 一般要求 1.pdf(74页珍藏版)》请在麦多课文档分享上搜索。
1、 AMERICAN NATIONAL STANDARD ANSI/ISA-61241-0 (12.10.02)-2006 (R2011) Electrical Apparatus for Use in Zone 20, Zone 21 and Zone 22 Hazardous (Classified) Locations General Requirements Approved 29 March 2011 ANSI/ISA-61241-0 (12.10.02)-2006 (R2011), Electrical Apparatus for Use in Zone 20, Zone 21 an
2、d Zone 22 Hazardous (Classified) Locations General Requirements ISBN: 978-1-936007-88-2 Copyright 2011 by IEC and ISA. Not for resale. Printed in the United States of America. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means (ele
3、ctronic mechanical, photocopying, recording, or otherwise), without the prior written permission of the Publisher. ISA 67 Alexander Drive P.O. Box 12277 Research Triangle Park, North Carolina 27709 - 3 - ANSI/ISA-61241-0 (12.10.02)-2006 (R2011) Preface This preface, as well as all footnotes and anne
4、xes, is included for information purposes and is not part of ANSI/ISA-61241-0 (12.10.02)-2011. This document has been prepared as part of the service of ISA toward a goal of uniformity in the field of instrumentation. To be of real value, this document should not be static but should be subject to p
5、eriodic review. Toward this end, the Society welcomes all comments and criticisms and asks that they be addressed to the Secretary, Standards and Practices Board; ISA; 67 Alexander Drive; P. O. Box 12277; Research Triangle Park, NC 27709; Telephone (919) 549-8411; Fax (919) 549-8288; E-mail: standar
6、dsisa.org. The ISA Standards and Practices Department is aware of the growing need for attention to the metric system of units in general, and the International System of Units (SI) in particular, in the preparation of instrumentation standards. The Department is further aware of the benefits to USA
7、 users of ISA standards of incorporating suitable references to the SI (and the metric system) in their business and professional dealings with other countries. Toward this end, this Department will endeavor to introduce SI-acceptable metric units in all new and revised standards, recommended practi
8、ces, and technical reports to the greatest extent possible. Standard for Use of the International System of Units (SI): The Modern Metric System, published by the American Society for Testing temperature tested under 500 mm dust layer, for use in Zone 21 . 57 30.5 Apparatus type of protection “tD“,
9、Practice B (see IEC 61241-1) for use in Zone 22 . 57 30.6 Apparatus type of protection “tD“, Practice A (see IEC 61241-1) for use in Zone 22 . 57 Annex A (informative) Common standards Safety requirements for electrical equipment 59 Annex B (informative) Equipment grounding. 61 Annex C (informative)
10、 United States major deviations. 63 Bibliography . 71 This page intentionally left blank. - 13 - ANSI/ISA-61241-0 (12.10.02)-2006 (R2011) Foreword All text of IEC 61241-0:2004 (1stedition) is included. U.S. National Deviations are shown by strikeout through text deleted and underline under text adde
11、d. There are three annexes in this standard. All are informative and are not considered part of this standard. This page intentionally left blank. - 15 - ANSI/ISA-61241-0 (12.10.02)-2006 (R2011) 1 Scope This standard part of IEC 61241 specifies general requirements for the design, construction, test
12、ing and marking of which is applicable to electrical apparatus protected by any recognized safeguard protection technique for use in areas where combustible dust may be present in quantities that could lead to a fire or explosion hazard. This standard is supplemented or modified by the following sta
13、ndards parts of IEC 61241 concerning specific types of protection: ANSI/ISA-61241-1 (12.10.03), Electrical Apparatus for Use in Zone 21 and Zone 22 Hazardous (Classified) Locations Protection by Enclosures “tD” Part 1: Protection by enclosures tD ANSI/ISA-61241-2 (12.10.06), Electrical Apparatus for
14、 Use in Zone 21 and Zone 22 Hazardous (Classified) Locations Protection by Pressurization “pD” Part 2: Protection by pressurization pD (under consideration) ANSI/ISA-61241-11 (12.10.04), Electrical Apparatus for Use in Zone 20, Zone 21, and Zone 22 Hazardous (Classified) Locations Protection by Intr
15、insic Safety “iD” Part 11: Intrinsically safe apparatus ANSI/ISA-61241-18 (12.10.07), Electrical Apparatus for Use in Zone 20, Zone 21 and Zone 22 Hazardous (Classified) Locations Protection by Encapsulation “mD” Part 18: Protection by encapsulation mD NOTE IEC 61241-14 gives guidance on the selecti
16、on and installation of the apparatus. Apparatus within the scope of this standard may also be subjected to additional requirements in other standards for example, IEC 60079-0. The application of electrical apparatus in atmospheres which may contain explosive gas as well as combustible dust, whether
17、simultaneously or separately, requires additional protective measures. This standard does not specify requirements for safety, other than those directly related to the explosion risk. Where the apparatus has to meet other environmental conditions, for example, protection against ingress of water and
18、 resistance to corrosion, additional methods of protection may be necessary. The method used is not to adversely affect the integrity of the enclosure. This standard does not apply to dusts of explosives that do not require atmospheric oxygen for combustion, or to pyrophoric substances. This standar
19、d is not applicable to electrical apparatus intended for use in underground parts of mines as well as those parts of surface installations of such mines endangered by firedamp and/or combustible dust. This standard does not take account of any risk due to an emission of flammable or toxic gas from t
20、he dust. Electrical apparatus and Ex components for use in explosive dust atmospheres shall also comply with the applicable requirements for similar apparatus for use in unclassified locations. ANSI/ISA-61241-0 (12.10.02)-2006 (R2011)- 16 - NOTE Requirements for safety of electrical equipment in ord
21、inary (unclassified) locations can be found in ANSI Standards, NEMA Standards, Federal Regulations, etc. Apparatus listed by a Nationally Recognized Testing Laboratory is considered to meet the applicable requirements found in these standards. A list of commonly applied standards is shown in informa
22、tive Annex A. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60034-5:
23、2000, Rotating electrical machines Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) Classification IEC 60079-0:2004, Electrical apparatus for explosive gas atmospheres - Part 0: General requirementsANSI/ISA-60079-0 (12.00.01)-2005, Electrical Ap
24、paratus for Use in Class I, Zones 0, 1 based upon the frequency and duration of the occurrence of explosive dust/air atmospheres 3.16 Zone 20 place in which an explosive atmosphere in the form of a cloud of combustible dust in air is present continuously, or for long periods or frequently an area wh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISA6124102006ELECTRICALAPPARATUSFORUSEINZONE20ZONE21ANDZONE22HAZARDOUSCLASSIFIEDLOCATIONSGENERALREQUIREMENTS121002

链接地址:http://www.mydoc123.com/p-789731.html