1、 WORLDWIDE ENGINEERING STANDARDS Test Procedure GMW3431 General Procedures for Testing Switches Copyright 2012 General Motors Company All Rights Reserved June 2012 Originating Department: North American Engineering Standards Page 1 of 46 1 Scope This test procedure defines the test conditions and th
2、e test procedures for functional, environmental and durability tests of Switches which are installed in the vehicle. Additional necessary requirements, (e.g., definition of the function of the switches and the functional accuracy including the determination of the tolerance range, or the establishme
3、nt of specific test procedures) are specified in relevant specifications (i.e., Component Technical Specification (CTS) or part drawing. Note: Nothing in this standard supercedes applicable laws and regulations. Note: In the event of conflict between the English and domestic language, the English la
4、nguage shall take precedence. 1.1 Purpose. This standard is intended to document unique or specific electrical, mechanical, environmental and durability tests for automotive switches. 1.2 Foreword. Not applicable. 1.3 Applicability. This procedure covers the laboratory testing of automotive switches
5、 containing sliding or separating electrical contacts. The method of actuation includes, but is not limited to, differentials in: temperature, pressure, vacuum, fluid level, mounting angle (tilt), or displacement. This procedure applies to the following types of devices: Mechanical Switches Devices
6、containing electrical contacts without electronic content. Electromechanical Switches Mechanical switches containing any of the following: resistors, capacitors, diodes, Light Emitting Diodes (LED), and discrete transistors. Electronic Switches Electromechanical or Solid-State (semiconductor based)
7、switches with electronic content for logic or decision making. 2 References Note: Only the latest approved standards are applicable unless otherwise specified. 2.1 External Standards/Specifications. ASTM B539 FMVSS 206 IEC 60068-2-60 SAE J726 ASTM D4728 IEC 60068-2-6 ISO 1431-1 SAE J1330 CMVSS 206 I
8、EC 60068-2-27 ISO 12103-1 SAE J1885 2.2 GM Standards/Specifications. GMW3172 GMW3208 GMW14528 GMW16449 GMW3191 GMW3232 GMW14829 2.3 Additional References. TS/ISO 16949 or ISO 9000 registration 2.3.1 Missing information or other applicable tests and the test order can be found on the Part Drawing, th
9、e CTS, or other relevant document. Note: The information and requirements in the CTS and the Part Drawing supercede requirements in this document. Test Description. The laboratory test order shall provide location and documentation of test samples, identify the type of test to be performed (investig
10、ative or validation) and describe special tests when not part of this procedure. Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW3431 Cop
11、yright 2012 General Motors Company All Rights Reserved June 2012 Page 2 of 46 Investigative Tests. Investigative tests are frequently used to evaluate specific areas of the design, as a tool in the designing of the product for trouble checks or to evaluate proposed quality improvement or cost saving
12、s concepts. Special instrumentation or measurements requiring sample disassembly preclude investigative tests for validation or supplier approval samples. Investigative tests may be continued even after a technical part failure has occurred to learn more about the device under test (DUT). Validation
13、 Tests. Validation tests or sample approval tests are tests which are used to confirm that the product meets the requirements stipulated in the CTS, component drawing, material specification, Federal Motor Vehicle Safety Standards (FMVSS), and any other specification used to define the product requi
14、rements. 3 Resources 3.1 Facilities. The test facilities shall be ISO 9000 or TS/ISO 16949 registered. 3.1.1 Calibration. The test facilities and equipment shall be in good working order and shall have a valid calibration label. 3.1.2 Alternatives. Alternative test facilities and equipment may also
15、be used. However, all alternative test facilities must meet all test facility and equipment requirements. 3.2 Equipment. Power Sources, Performance, and Static Characteristics. 3.2.1 Output Current. The power source shall be capable of supplying a continuous output current as required by the design
16、loads including inrush and stall currents. 3.2.2 Regulation. The output voltage shall not deviate more than 1.0 V from zero to maximum load (including surges) and shall recover 63% of its maximum excursion within 5.0 ms. 3.2.3 Ripple Voltage. Ripple voltage shall not exceed 300 mV peak to peak for n
17、ominal 12 volt sources or 100 mV peak to peak for nominal 5 volt sources. 3.2.4 Auxiliary Battery Requirements. An automotive battery of 450 cold cranking amperes to 650 cold cranking amperes shall be connected in parallel with the power supply. Where all test samples are energized instead of in seq
18、uence, or where more than eleven (11) samples are tested, use a battery or batteries capable of at least 100 cold cranking amperes per sample. The supplier must ensure that the battery maintains consistent operation throughout the test sequence. 3.3 Test Vehicle/Test Piece. If not otherwise stated,
19、the number of test pieces and conditioning shall be as specified in the relevant technical specification. Production samples shall be selected at random from pieces which have been subjected to all normal processing including final packaging. 3.3.1 Conditioning. Reference individual conditioning req
20、uirements. 3.4 Test Time. Not applicable. 3.5 Test Required Information. Not applicable. 3.6 Personnel/Skills. Not applicable. 3.7 Parameter Definition and Tolerance. 3.7.1 Test Tolerances. Test setups and equipment shall be capable of maintaining test parameters within the limits found in Table 1 u
21、nless otherwise stipulated in the CTS or in this procedure. Table 1: Parameters and Tolerances Test Parameter Applied Tolerance Air Pressure (Laboratory) 6540 mm Hg to 800 mm Hg Room Temperature (23 5) C High Ambient Temperature, Reference GMW3172 (Tmax -0/+5) C Low Ambient Temperature, Reference GM
22、W3172 (Tmin -5/+0) C Chamber Humidity As specified 5% Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW3431 Copyright 2012 General Motors
23、Company All Rights Reserved June 2012 Page 3 of 46 Test Parameter Applied Tolerance Time As specified 5% Forces As specified 5% Distances As specified 1% Nominal Operating Voltage (14.0 0.1) V Voltage (As specified 0.1) V Current (Performance Test) As specified 15% Current (Durability Test) As speci
24、fied 15% Vibration As specified 0.2G or 20% (whichever is greater) Shock As specified 20% Frequency As specified 1% 3.7.2 Measurement Accuracy. Meters and gauges used to assess the performance dependent variable as defined by the basic function of the test sample shall be capable of measuring to one
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMWGMW34312012GENERALPROCEDURESFORTESTINGSWITCHESISSUE2ENGLISHPDF

链接地址:http://www.mydoc123.com/p-758035.html