FORD WSK-M1L131-A1-2003 CABLE LOW TENSION TPE INSULATED 150 THIN WALL SHIELDED BARE TRIPLE CORE TO BE USED WITH FORD WSS-M99P1111-A 《最高工作温度150℃的薄护皮热塑性弹性体(TPE)绝缘的屏蔽和扭绞三芯低压裸电缆 与标准.pdf
《FORD WSK-M1L131-A1-2003 CABLE LOW TENSION TPE INSULATED 150 THIN WALL SHIELDED BARE TRIPLE CORE TO BE USED WITH FORD WSS-M99P1111-A 《最高工作温度150℃的薄护皮热塑性弹性体(TPE)绝缘的屏蔽和扭绞三芯低压裸电缆 与标准.pdf》由会员分享,可在线阅读,更多相关《FORD WSK-M1L131-A1-2003 CABLE LOW TENSION TPE INSULATED 150 THIN WALL SHIELDED BARE TRIPLE CORE TO BE USED WITH FORD WSS-M99P1111-A 《最高工作温度150℃的薄护皮热塑性弹性体(TPE)绝缘的屏蔽和扭绞三芯低压裸电缆 与标准.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2003 08 13 Revised Para 3.0 inserted; Para 3.1, 3.2, 3.21, 4 deleted 1992 10 10 EE00E10176310000 Pages 1, 3, 9, 10 Revised MD/FE-12 P. Rade 1992 04 28 EE00E10206442000 Released MD/FE-12 P. Rade Printed copies are uncontrolled Copyright 2003, F
2、ord Global Technologies, Inc. Page 1 of 8 CABLE, LOW TENSION, TPE INSULATED, 150 C, WSK-M1L131-A1 THIN WALL, SHIELDED, BARE, TRIPLE CORE CABLE, LOW TENSION, TPE INSULATED, 135 C, WSK-M1L131-A2 THIN WALL, SHIELDED, BARE, TRIPLE CORE CABLE, LOW TENSION, TPE INSULATED, 135 C, WSK-M1L131-A3 THIN WALL, S
3、HIELDED, TINNED, TRIPLE CORE 1. SCOPE The material defined by these specifications is a low tension stranded cable, thermoplastic elastomer (TPE) insulated conductor. The cable is similar to ISO 6722 with a thin wall insulation thickness. It is a spirally wound shielded wire with a 90% shield cover
4、and a helix angle of 10%. 2. APPLICATION These specifications were released originally for materials used in automotive electrical harnesses. Note: The assemblers of electrical wire harnesses shall use the bulk wire suppliers as shown in the Ford Motor Company Approved Source List. 3. REQUIREMENTS 3
5、.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.3 CABLE 3.3.1 Specimen Length 1.2 m 3.3.2 The maximum outside diameter shall be determined by taking measurements at
6、 three points along the conductor length separated by at least 100 mm and recording the greatest overall diameter at each point. No single value shall exceed the maximum overall diameter as specified in Table 2. 3.4 CONDUCTOR 3.4.1 The conductor of all cable classes shall consist of bunched or stran
7、ded soft annealed copper wire. 3.4.2 Specimen Length 1.2 m 3.4.3 Three sections 10 mm long and separated by at least 400 mm shall be cut from the specimen. Carefully remove the conductor without deformation of the insulation. ENGINEERING MATERIAL SPECIFICATIONWSK-M1L131-A1/A2/A3Printed copies are un
8、controlled Copyright 2003, Ford Global Technologies, Inc. Page 2 of 8 3.4.4 The conductor diameter shall be determined by measuring the inside diameter of the insulation taken at three points separated by at least 100 mm and recording the maximum inside diameter at each point. The measurements shall
9、 be made with an optical device accurate to at least 0.01 mm. No value shall exceed the maximum diameter of the conductor specified in Table 2. 3.4.5 The conductor area may be determined by measuring individual strand diameters and calculating the sums of the individual strand areas. As an alternate
10、 method, conductor area may also be determined in accordance with FLTM BB 105-01 or by measuring the resistance in accordance with tables 1a and 1b. 3.4.6 The strands shall be bunched and the maximum lay length shall be a maximum of 50 times the conductor diameter. Minimum number of wires shall comp
11、ly with Tables 1 and 2. Maximum variation between individual strand diameters must not exceed 10% per the following: max strand dia - min strand dia Variation = _ min strand dia Missing strands are not allowed. 3.4.7 Elongation (ASTM B 3) For d 15% For d 0.287 mm e 20% Where: d = individual strand d
12、iameter e = elongation of individual strand 3.4.8 Resistivity, max (ASTM B 193, at 20 C) Bare 1.7094 microohm/cm Tinned 1.7544 microohm/cm 3.5 INSULATION AND SHEATHING 3.5.1 The insulating material shall be a thermoplastic elastomer (TPE) material, homogeneous in character. The surface shall be smoo
13、th and even without cracks, knots, blisters, or other faults. 3.5.2 The color of the cables are per the Munsell Color Coding System and shall conform to Table 3. Comparison must be made by a person with normal or corrected vision, under cool white fluorescent lighting. The surface being inspected an
14、d the tolerance set must be the same plane. Cable samples must be placed flat, overlapping the color standard. Color tolerance Reference Sets are available from SAE, 400 Commonwealth Drive, Warrendale, PA 15096. As an alternative, the color of the cables can be per the DIN 47002 or IEC 304 and shall
15、 conform to Table 4. ENGINEERING MATERIAL SPECIFICATIONWSK-M1L131-A1/A2/A3Printed copies are uncontrolled Copyright 2003, Ford Global Technologies, Inc. Page 3 of 8 3.5.3 The minimum insulation thickness shall be determined by taking measurements at three points separated by at least 100 mm and reco
16、rding the minimum insulation thickness at each point. The thickness shall be measured with an optical device accurate to at least 0.01 mm. No single value shall be lower than the minimum insulation thickness specified in Table 2. 3.6 CABLE CONSTRUCTION 1= CONDUCTOR CU 2= INSULATION TPE 3= SHIELDING
17、SPIRALLY WOUND SHIELD, COPPER 90% SHIELD COVER, HELIX ANGLE 10 DEGREE 4= SHEATHING TPE (BLACK) 3.7 FAULT TESTING OF THE COMPLETE DELIVERY (in process testing) 3.7.1 When pulling the grounded dry cable through the test electrodes connected to the test voltage, there must be no punctures. The test ele
18、ctrodes may consist of a coil, a metal tube, metal ball chains or any other type of suitable electrode. 3.7.2 Test Voltage For wires 0.5 mm25 kVeff For conductor against shield 1.5 kVeff for 1 minute The power supply shall be a transformer delivering a sinusoidal voltage. The electrode length and th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDWSKM1L131A12003CABLELOWTENSIONTPEINSULATED150THINWALLSHIELDEDBARETRIPLECORETOBEUSEDWITHFORDWSSM99P1111A

链接地址:http://www.mydoc123.com/p-750344.html