《FORD ESH-M4D160-E-2010 HOSE MEDIUM PRESSURE REFRIGERANT ACID RESISTANT SLEEVE COVERLESS TO BE USED WITH FORD WSS-M99P1111-A (Shown on FORD ESA-M4D160-C)《无罩的中压制冷耐酸套管软管 与福特WSS-M99.pdf》由会员分享,可在线阅读,更多相关《FORD ESH-M4D160-E-2010 HOSE MEDIUM PRESSURE REFRIGERANT ACID RESISTANT SLEEVE COVERLESS TO BE USED WITH FORD WSS-M99P1111-A (Shown on FORD ESA-M4D160-C)《无罩的中压制冷耐酸套管软管 与福特WSS-M99.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATION Material Name Specification Number Date Action Revisions 2010 10 07 N-STATUS No replacement named L. Soreide, NA 88 09 30 RD-367000-C12 Revised and Retyped 1963 06 05 AS1-915 Released T for 3.2 mm thick spec (expires01/88) Page 1 of 6 HOSE, MEDIUM PRESSURE - AIR C
2、ONDITIONING UNITS ESA-M4D160-C NYLON CONSTRUCTION ACID RESISTANT SLEEVE HOSE, MEDIUM PRESSURE REFRIGERANT ESH-M4D160-E ACID RESISTANT SLEEVE COVERLESS NOT TO BE USED FOR NEW DESIGN 1. SCOPE: The hoses defined by this specification are constructed from an extruded heat stabilized seamless nylon tube
3、and reinforced with nylon yarn. 2. APPLICATION: This specification was released originally for hoses used for suction and liquid lines in automotive air conditioning systems. 3. REQUIREMENTS: 3.1 NON-PIGMENTED INJECTION MOLDED TEST BARS (Tube only, raw material conforms to ESB-M4D278-A) 3.1.1 Color
4、Natural 3.1.2 Specific Gravity 1.12 - 1.16 (ASTM D 792) 3.1.3 Tensile Strength at Break, min 7000 psi (48.3 MPa) (ASTM D 638, dry as molded) 3.1.4 Elongation at Break, min 250% (ASTM D 638) 3.1.5 Melting Point, min 205 C (FLTM BO 21-2) 3.1.6 Flexural Modulus, max 75 000 psi (517 MPa) (ASTM D 790) 3.
5、2 EXTRUDED TUBE, non-reinforced 3.2.1 Burst Pressure (ASTM D 1680) As extruded See Table 4, Burst Pressure ENGINEERING MATERIAL SPECIFICATION ESA-M4D160-C ESH-M4D160-E Page 2 of 6 Change in burst after heat aging -20% 125 C for 72 h, max 3.3 HOSE, with acid resistant sleeve 3.3.1 Dimensional Toleran
6、ces and Eccentricity Hose I.D. and 0.D. limits shall be as shown in Table 1 of this specification and/or as shown on the engineering released drawing. The outer surface shall be concentric with the inside bore of the hose within the limits shown in Table 2. 3.3.2 Elongation and Contraction Hoses sha
7、ll not exceed +/- 2% change in length when subjected to pressure of 450 psi (3.1 MPa). Collapse of the hose 0.D. shall not exceed 20% of the original 0.D. nor more than 50% of the original I.D. when exposed to vacuum of 25 in Hg (85 kPa). 3.3.3 Heat Aging (Use new hose, destroy after) Coil the hose
8、(uncapped) around a mandrel having a diameter equal to the minimum bend diameter shown in Table 3 and expose to a temperature of 110 C for 72 h. After cool the hose to room temperature, then straighten and rebend 180 deg around the mandrel. Remove and examine for fractures on the outside and inside.
9、 There must be no visual evidence of fracturing on the 0.D. and I.D. 3.3.4 Cold Flexibility (Use new hose, destroy after) Precondition the hose prior to cold soak by exposing to 70 C for 168 h then immersing in 65 C water for 4 h. Immediately following water immersion, cold soak the hose in straight
10、 lengths for 48 h at -40 C. Immediately following, bend the hose 180 deg around a mandrel having a diameter equal to the minimum bend diameter (shown on Table 3), which has also been cold soaked to -40 C. Hose shall not show evidence of fracturing after this test. Check visually for fractures and hy
11、drostatic test at 350 psi (2.4 MPa) for 5 min. (Suffix “C“ test at -29 C instead of -40 C.) ENGINEERING MATERIAL SPECIFICATION ESA-M4D160-C ESH-M4D160-E Page 3 of 6 3.3.5 Refrigerant 12 Effusion (Permeation) (Use new hose) All permeation rates are for assemblies using 1/2 in I.D. hose. Other diamete
12、rs shall have maximum permeation rates proportional to the ratio of the inside diameters (i.e., 1 in I.D. has 2 times the allowable permeation rate as 1/2 in I.D.), unless otherwise specified. Four coupled hose assemblies with 30 in (750 mm) of exposed flexible hose between couplings or metal fittin
13、gs and with both ends adaptable for plugging are to be used for this test. Permeation test is to be conducted as follows: 3.3.5.1 Flush out hose assemblies with commercially acceptable cleaning agents (stanisol or iso-octane) and blow out residue with dry air n Loosely cap both ends of hose and cool
14、 to below -30 C. Tighten both caps on one hose (in each set of 4) which will serve as an “empty“ hose for measuring loss in hose weight. Uncap one end of the remain in hoses and add liquid refrigerant 12, equivalent to 8 +/- 1.0 g/in3 (0.49 +/- 0.06 g/cm3) of internal volume. Recap and tighten both
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDESHM4D160E2010HOSEMEDIUMPRESSUREREFRIGERANTACIDRESISTANTSLEEVECOVERLESSTOBEUSEDWITHFORDWSSM99P1111ASHOWNONFORDESAM4D160C

链接地址:http://www.mydoc123.com/p-746368.html