EN 50600-4-2-2016 en Information technology - Data centre facilities and infrastructures - Part 4-2 Power Usage Effectiveness.pdf
《EN 50600-4-2-2016 en Information technology - Data centre facilities and infrastructures - Part 4-2 Power Usage Effectiveness.pdf》由会员分享,可在线阅读,更多相关《EN 50600-4-2-2016 en Information technology - Data centre facilities and infrastructures - Part 4-2 Power Usage Effectiveness.pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、Information technology Data centre facilities andinfrastructuresPart 4-2: Power Usage EffectivenessBS EN 50600-4-2:2016Incorporating corrigendum February 2017BSI Standards PublicationBS EN 50600-4-2:2016 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 50600-4-2:
2、2016, incorporating corrigendum February 2017.The UK participation in its preparation was entrusted to Technical Committee TCT/7, Telecommunications - Installation requirements.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not
3、 purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017. Published by BSI Standards Limited 2017ISBN 978 0 580 97919 4ICS 35.020; 35.110; 35.160Compliance with a British Standard cannot confer immunity
4、from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2017.Amendments/corrigenda issued since publicationDate Text affected31 March 2017 Implementation of CENELEC corrigendum February 2017: Figure B.2, Figure B.6 a
5、nd Figure B.7 correctedBS EN 50600-4-2:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 50600-4-2 December 2016 ICS 35.020; 35.110; 35.160 English Version Information technology - Data centre facilities and infrastructures - Part 4-2: Power Usage Effectiveness Technologie de linformation - I
6、nstallation et infrastructures de centres de traitement de donnes - Partie 4-2 : Efficacit de lutilisation de lnergie Informationstechnik - Einrichtungen und Infrastrukturen von Rechenzentren - Teil 4-2: Kennzahl zur eingesetzten Energie This European Standard was approved by CENELEC on 2016-10-10.
7、CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained
8、on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the
9、 CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hun
10、gary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechni
11、que Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 50600-4-2:2016 EBS EN 50600-4-2:2016EN 50600-4-2:2016 2 Conte
12、nts PageEuropean foreword 5 Introduction . 6 1 Scope . 9 2 Normative references . 9 3 Terms, definitions and abbreviations . 9 3.1 Terms and definitions . 9 3.2 Abbreviations 10 3.3 Symbols 11 4 Applicable area of the data centre . 11 5 Determination of Power Usage Effectiveness 12 5.1 General . 12
13、5.2 Total data centre energy consumption . 12 5.3 Total data centre energy consumption in mixed-use buildings 13 6 Measurement of Power Usage Effectiveness 13 6.1 Measuring energy consumption . 13 6.1.1 General 13 6.1.2 Measurement period and frequency . 13 6.1.3 Meter and measurement requirements .
14、 13 6.2 Categories of Power Usage Effectiveness . 14 6.2.1 General 14 6.2.2 Category 1 (PUE1) basic resolution . 14 6.2.3 Category 2 (PUE2) intermediate resolution . 15 6.2.4 Category 3 (PUE3) advanced resolution . 15 6.2.5 Measurement placement. 15 7 Reporting of Power Usage Effectiveness 15 7.1 Re
15、quirements . 15 7.1.1 Standard construct for communicating PUE data . 15 7.1.2 Example of reporting PUE values . 15 7.1.3 Data for public reporting PUE . 16 7.2 Recommendations . 16 7.2.1 Use of PUE Category 16 7.2.2 Trend tracking data . 16 Annex A (normative) Energy measurements 18 A.1 Measuring e
16、nergy and calculating Power Usage Effectiveness 18 A.2 Measurement locations 18 BS EN 50600-4-2:2016EN 50600-4-2:2016 3 A.3 Assessment frequencies 19 Annex B (informative) Calculation of PUE using various energy supplies 20 B.1 Examples of PUE calculation with various energy supplies. 20 B.2 Example
17、s of PUE calculation with cogeneration using electricity and natural gas 21 B.3 Examples of PUE calculation with absorption type chiller . 22 Annex C (normative) PUE derivatives . 24 C.1 General . 24 C.1.1 Purpose of PUE derivatives 24 C.1.2 Using PUE derivatives 24 C.2 Interim PUE 25 C.3 Partial PU
18、E (pPUE) 25 C.3.1 General 25 C.3.2 Zoning . 26 C.3.3 Metering requirements for pPUE 27 C.3.4 Reporting of pPUE 27 C.3.5 Use of pPUE in energy management . 28 C.3.6 Use of pPUE in mixed use buildings . 28 C.4 Designed PUE 29 Annex D (informative) Interpretation of PUE and its derivatives . 32 D.1 Gen
19、eral . 32 D.2 Data centre infrastructure versus IT equipment . 32 D.3 Comparing PUE results between data centres 33 Bibliography 34 Figures Figure 1 Schematic relationship between the EN 50600 series of documents . 7 Figure A.1 Schematic of PUE calculation from measurements . 18 Figure A.2 Monitorin
20、g and measurement points 19 Figure B.1 Example for a data centre purchasing all electricity. 20 Figure B.2 Example for a data centre purchasing electricity and chilled water . 20 Figure B.3 Example for a data centre purchasing natural gas 21 Figure B.4 Example for a data centre purchasing electricit
21、y and natural gas . 21 Figure B.5 Method 1: Measured by chilled water flow . 22 Figure B.6 Method 2: Calculated from energy required to produce chilled water . 22 Figure B.7 Method 1: Measured by chilled water flow . 22 Figure B.8 Method 2: Measured by input gas 23 Figure C.1 Zoning for a data centr
22、e . 26 Figure C.2 Zoning for a data centre using DX cooling . 27 Figure C.3 Zoning for a data centre using water . 27 Figure C.4 Example of utilizing the combination of PUE derivatives: ipPUE 28 BS EN 50600-4-2:2016EN 50600-4-2:2016 4 Tables Table 1 PUE Categories 14 Table 2 Examples of PUE reportin
23、g 15 Table C.1 Example of dPUE calculation 30 Table C.2 Example of context description . 31 BS EN 50600-4-2:2016EN 50600-4-2:2016 5 European foreword This document (EN 50600-4-2:2016) has been prepared by CLC/TC 215 “Electrotechnical aspects of telecommunication equipment”. The following dates are f
24、ixed: latest date by which this document hasto be implemented at national level bypublication of an identical nationalstandard or by endorsement(dop) 2017-07-10 latest date by which the nationalstandards conflicting with thisdocument have to be withdrawn(dow) 2019-10-10 Attention is drawn to the pos
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN50600422016ENINFORMATIONTECHNOLOGYDATACENTREFACILITIESANDINFRASTRUCTURESPART42POWERUSAGEEFFECTIVENESSPDF

链接地址:http://www.mydoc123.com/p-717318.html