《ECA EIA-364-1004A-2016 TS-1004A Environmental Test Methodology for Verifying the Current Rating of Freestanding Power Contacts or Electrical Connectors and Sockets.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-364-1004A-2016 TS-1004A Environmental Test Methodology for Verifying the Current Rating of Freestanding Power Contacts or Electrical Connectors and Sockets.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD TS-1004A Environmental Test Methodology for Verifying the Current Rating of Freestanding Power Contacts or Electrical Connectors and Sockets EIA-364-1004A (Revision of EIA-364-1004) March 2016 Electronic Components Industry Association ANSI/EIA-364-1004A-2016 Approved: March 23, 2016 E
2、IA-364-1004A NOTICE EIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining wit
3、h minimum delay the proper product for his particular need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standar
4、ds and Publications preclude their voluntary use by those other than ECIA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such acti
5、on, ECIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This EIA standard is considered to have International Standardization implications, but the International Electrotechnical Commission activity has n
6、ot progressed to the point where a valid comparison between the EIA standard and the IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to est
7、ablish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No. 5352 formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Sockets Standards.) Published by Electronic Components I
8、ndustry Association 2016 EIA Standards & Technology Department 2214 Rock Hill Road, Suite 265 Herndon, VA 20170 PLEASE ! DONT VIOLATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of c
9、opies through entering into a license agreement. For information, contact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-877-413-5186), International (303-397-7956) i CONTENTS Clause Page 1 Introduction . 1 1.1 Scope . 1 1.2 Object 1 1.3 Definition 1 2 Test specimen 2
10、2.1 Description 2 2.2 Preparation 2 3 Test sequence 2 3.1 Test groups 2 3.2 Test groups 1, 2 and 3 . 3 3.3 Stabilization 3 3.4 Special applications 3 4 Details to be specified . 4 5 Test documentation . 5 Table 1 Tests and sequences 4 ii (This page left blank) EIA-364-1004A Page 1 TEST SEQUENCE No.
11、1004A ENVIRONMENTAL TEST METHODOLOGY FOR VERIFYING THE CURRENT RATING OF FREESTANDING POWER CONTACTS OR ELECTRICAL CONNECTORS AND SOCKETS (From EIA Standards Proposal No. 5352, formulated under the cognizance EIA CE-2.0 Committee on National Connector Standards, and previously published in EIA-364-1
12、004) 1 Introduction 1.1 Scope This standard describes recommended test sequences for verifying the specified current rating of freestanding contacts or electrical connectors and sockets used in power applications. These sequences may be used for developmental purposes and not for qualifying products
13、 with a specified current rating. 1.2 Object 1.2.1 Joule, or I2R, heating occurs in all current-carrying contacts. The associated temperature rise (T-rise) may lead to accelerated thermal degradation and possible, thermal runaway. This possibility gives rise to safety concerns which are generally ad
14、dressed by specification of a maximum T-rise at the device rated current. To ensure temperature rise stability, requires that the device maintain a stable value of resistance over the product lifetime. The test sequences in this standard are extreme environmental stresses and thus are intended to ve
15、rify the T-rise and resistance stability of electrical connectors and sockets after exposure to simulated application stresses. 1.3 Definitions For the purpose of this standard the following definitions apply: 1.3.1 Current rating The maximum current that results in a specified steady state T-rise o
16、f a contact when in a terminated state for its intended application, as specified in the manufacturers literature. EIA-364-1004A Page 2 2 Test specimens 2.1 Description 2.1.1 Unless otherwise specified in the reference document, three connectors shall be prepared for each test group, see 3.4. For fr
17、eestanding contacts, five contacts shall be prepared for testing. 2.2 Preparation Unless otherwise specified in the referencing document the test samples shall be terminated to the maximum size conductors. In no case shall the current rating of the conductor size being tested be exceeded. 2.2.1 For
18、printed circuit board connectors, the traces shall be designed to carry the specified current. 2.2.2 See EIA-364-70 (Temperature Rise Versus Current Test Procedure for Electrical Connectors and Sockets) to select appropriate wire lengths, and board trace lengths and widths. 2.2.3 Unless otherwise sp
19、ecified in the referencing document the connectors shall be tested with a full compliment of contacts appropriately terminated to carry the rated current as specified. 2.2.4 Unless otherwise specified in the referencing document, the connector with the largest contact population shall be tested. 3 T
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA3641004A2016TS1004AENVIRONMENTALTESTMETHODOLOGYFORVERIFYINGTHECURRENTRATINGOFFREESTANDINGPOWERCONTACTSORELECTRICALCONNECTORSANDSOCKETSPDF

链接地址:http://www.mydoc123.com/p-704188.html