ECA EIA-364-06C-2006 TP-06C Contact Resistance Test Procedure for Electrical Connectors.pdf
《ECA EIA-364-06C-2006 TP-06C Contact Resistance Test Procedure for Electrical Connectors.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-364-06C-2006 TP-06C Contact Resistance Test Procedure for Electrical Connectors.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD TP-06C Contact Resistance Test Procedure for Electrical Connectors EIA-364-06C (Revision of EIA-364-06B) March 2006 Electronic Components Industry Association EIA-364-06C ANSI/EIA-364-06C-2006(R2017) Approved: March 21, 2006 Reaffirmed: August 21, 2017 NOTICE EIA Engineering Standards
2、and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his par
3、ticular need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary u
4、se by those other than ECIA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any
5、patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid compar
6、ison between the EIA Standard and the IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices
7、and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No. SP-5393.02 formulated under the cognizance of the CE-2.0 National Connector Standards Committee). Published by Electronic Components Industry Association 2017 EIA Standards & Technology Departme
8、nt 2214 Rock Hill Road, Suite 265 Herndon, VA 20170 i PLEASE ! DONT VIOLATE THE LAW! This document is copyrighted by the EIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For inform
9、ation, contact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-800-854-7179), International (303-397-7956) ii CONTENTS Clause Page 1 Introduction . 1 1.1 Scope . 1 2 Test resources . 1 2.1 Equipment . 1 3 Test specimen 2 3.1 Description 2 3.2 Preparation 2 4 Test proced
10、ure . 2 5 Details to be specified . 3 6 Test documentation . 4 Figure 1 Test circuit 4 iii (This page left blank) EIA-364-06C Page 1 TEST PROCEDURE No. 06C CONTACT RESISTANCE TEST PROCEDURE FOR ELECTRICAL CONNECTORS (From EIA Standards Proposal No. 5106, formulated under the cognizance EIA CE-2.0 Co
11、mmittee on National Connector Standards, and previously published in EIA-364-06B.) 1 Introduction 1.1 Scope This standard establishes test methods to determine the resistance of mated connector contacts attached to lengths of wire by measuring the voltage drop across the contacts while they are carr
12、ying a specified current. 2 Test resources 2.1 Equipment 2.1.1 An ammeter capable of measuring the applied current to an accuracy of 2%. 2.1.2 A high-impedance voltmeter (in the order of 10,000 ohms per volt). The meter accuracy shall be such that the value being measured is accurate to 2%. NOTE For
13、 greater ease of measuring forward and reverse readings, a zero-center or digital voltmeter with automatic polarity reversal is recommended. 2.1.3 A suitable current source having a controlled output as required for test currents specified in the referencing document. Either ac or dc may be used for
14、 this contact resistance test. For ac measurements, the frequency shall not exceed 2 kHz. In the event of a discrepancy between ac and dc measurements, the dc method shall be employed. 2.1.4 An example of a test circuit is shown in figure 1 for the test method described in 4.2 through 4.5. EIA-364-0
15、6C Page 2 3 Test specimen 3.1 Description A test specimen shall consist of a mated connector, a pair of contacts such as a pin and a socket, mating hermaphroditic contacts, or a printed pad and its mating contacts. 3.2 Preparation 3.2.1 All specimens shall be prepared as they would be for normal app
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA36406C2006TP06CCONTACTRESISTANCETESTPROCEDUREFORELECTRICALCONNECTORSPDF

链接地址:http://www.mydoc123.com/p-704183.html