1、 MIL-DTL-13777/4C 13 June 2011 SUPERSEDING MIL-C-13777/4B 15 September 1969 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL 21, 22, 24, 26, 27, 28, AND 32 CONDUCTORS This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements fo
2、r acquiring the product described herein shall consist of this specification sheet and MIL-DTL-13777. REQUIREMENTS: Dimensions and configuration: See applicable figure and design data for the following cable types specified in table I. Design data is specified in table II. TABLE I. Cable types. 2110
3、55 211115S 211345 S221385 240966 241215S 241215 261065S 271100S 280805 321355 In any conflict between the design data and the applicable figure, the design data shall govern. AMSC N/A FSC 6145 Inactive for new design after 1 July 1998. INCH-POUND Provided by IHSNot for ResaleNo reproduction or netwo
4、rking permitted without license from IHS-,-,-MIL-DTL-13777/4C 2 TABLE II. Design data. Design data Type designation 211055 211115S Figure number 1 2 Total wires 21 21 Number of conductors & AWG # 15/#18 6/#12 5/#18S 10/#18 6/#12 Insulation Minimum average thickness 0.015” 0.020” 0.015” 0.020” Spark
5、test voltage 3000 4000 3000 4000 Inspection test voltage 1500 2000 1500 2000 Cabling Layer 1 Filler Filler Layer 2 (a) Number of wires 6 6 (b) AWG # #12 #12 (c) Maximum lay 4.00” 4.00” Layer 3 (a) Number of wires 15 5 10 (b) AWG # #18 #18S #18 (c) Maximum lay 7.00” 7.00” Sheath Number of layers 2 2
6、Total thickness minimum 0.120” 0.120” Minimum OD cable 1.040” 1.100” Maximum OD cable 1.070” 1.130” Maximum weight (lbs./1000ft.) 708 791 See notes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/4C 3 TABLE II. Design d
7、ata Continued. Design data Type designation 211345 S221385 Figure number 1 3 Total wires 21 22 Number of conductors & AWG # 15/#18 6/#9 3/#8 4/#12 14/#16 Insulation Minimum average thickness 0.015” 0.030” 0.060” 0.020” 0.015” Spark test voltage 3000 4000 7500 4000 3000 Inspection test voltage 1500 2
8、000 5000 2000 1500 Cabling Layer 1 Filler Filler Layer 2 (a) Number of wires 6 6 (b) AWG # #9 3/#8 3/#16 (c) Maximum lay 6.00” Layer 3 (a) Number of wires 15 16 (b) AWG # #18 4/#12 12/#16 (c) Maximum lay 9.00” 6.00” Sheath Number of layers 2 2 Total thickness minimum 0.156” 0.156” Minimum OD cable 1
9、.330” 1.360” Maximum OD cable 1.360” Maximum weight (lbs./1000ft.) 980 See notes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/4C 4 TABLE II. Design data Continued. Design data Type designation 240966 241215S Figure n
10、umber 4 5 Total wires 24 24 Number of conductors & AWG # 24/#18 12/#18S1/ 12/#18S2/ Insulation Minimum average thickness 0.015” 0.015” Spark test voltage 3000 3000 Inspection test voltage 1500 1500 Cabling Layer 1 (a) Number of wires 2 4 (b) AWG # #18 #18S3/(c) Maximum lay 3.50” Layer 2 (a) Number o
11、f wires 8 8 12 (b) AWG # #18 #18S4/#18S5/(c) Maximum lay 7.00” Layer 3 (a) Number of wires 14 (b) AWG # #18 (c) Maximum lay 4.5” Sheath Number of layers 2 2 Total thickness minimum 0.125” 0.100” Minimum OD cable 0.951” 1.200” Maximum OD cable 0.981” 1.230” See notes at end of table. Provided by IHSN
12、ot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/4C 5 TABLE II. Design data Continued. Design data Type designation 241215 261065S Figure number 6 7 Total wires 24 26 Number of conductors & AWG # 5/#18 19/#12 5/#18S 6/#18 12/#13 3/#12 Insulation Minimum
13、 average thickness 0.015” 0.020” 0.015” 0.018” Spark test voltage 3000 4000 3000 4000 Inspection test voltage 1500 2000 1500 1800 Cabling Layer 1 Filler (a) Number of wires 2 (b) AWG # #18S6/(c) Maximum lay Layer 2 (a) Number of wires 5 3 6 (b) AWG # #18 #18S #13 (c) Maximum lay 5.00” Layer 3 (a) Nu
14、mber of wires 7 6 6 3 (b) AWG # #12 #18 #13 #12 (c) Maximum lay 6.00” Layer 4 (a) Number of wires 12 (b) AWG # #12 (c) Maximum lay Sheath Number of layers 2 1 Total thickness minimum 0.098” 0.080” Minimum OD cable 1.190” 1.050” Maximum OD cable 1.240” 1.080” Maximum weight (lbs./1000ft.) 750 See not
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL137774C2011CABLESPECIALPURPOSEELECTRICAL212224262728AND32CONDUCTORSPDF

链接地址:http://www.mydoc123.com/p-689927.html