DIN 8607-1976 Machine Tools Lathes of Normal Accuracy Swing above 800 up to 1600 mm Acceptance Conditions《机床 旋转直径800 至1600mm标准精度车床 验收条件》.pdf
《DIN 8607-1976 Machine Tools Lathes of Normal Accuracy Swing above 800 up to 1600 mm Acceptance Conditions《机床 旋转直径800 至1600mm标准精度车床 验收条件》.pdf》由会员分享,可在线阅读,更多相关《DIN 8607-1976 Machine Tools Lathes of Normal Accuracy Swing above 800 up to 1600 mm Acceptance Conditions《机床 旋转直径800 至1600mm标准精度车床 验收条件》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Machine Tools Lathes of Normal Accuracy Swing above 800 up to 1600 mm Acceptance Conditions DIN I 8607 Werkzeugmaschinen; Drehmaschinen mit normaler Genauigkeit; Umiaufdurchmesser ber 800 bis 1600 mm; Abna hmebedingungen For connection with the International Standard IS0 1708-1 975 published by the
2、International Organization for Standardization (ISO), see Explanations. Dimensions in mm Type: Machine number: Recipient: Order num ber: Customer: Date: 1 Purpose and application This Standard defines technical acceptance conditions for lathes with normal accuracy, swing above 800 up to 1600 mm. The
3、y comprise preparatory measures, geometrical testings on the machine (manufacturing accuracy) and practical testings on workpieces (working accuracy). The test conditions conform to DIN 8601 (successor issue at present circulating as draft), see Explanations. If some of the testings are not to be ca
4、rried out or if additional testings are necessary, this is to be separately agreed between manufacturer and customer. The relevant German specifications are to be observed for testing the safety of the machine. The test procedures only state the test principle and the recommended test apparatus usua
5、lly to be found in the majority of firms. Other test procedures corresponding to DIN 8601 (successor issue at present circulating as draft) and of equivalent accuracy are permissible. In the column headed “Test instructions“ the section number from DIN 8601 (successor issue at present circulating as
6、 draft) is shown at the end in cases where the testing concerned corresponds to the stipulations contained therein. 2 Preparatory measures Object of testing Verifi- cation of level ling a in longi- tudinal direction Diagram a Test apparatus Precision level Optical or other methods Acces- sories (par
7、allels, measuring bridge etc.) suited to the type of slide- way Test instructions Carriage at middle of bed. Make the measure- ments at a number of positions equally spaced along the entire length of the bed. a Place the level on the front and rear slideways. Variations permissible a 0.015mrn L 1) u
8、p to 500mrn (convex) 0.03 mm L over 500 up to 1000mm (convex) 3) Local tolerance 2): 0.01 rnm over 250 mm. If the turning length exceeds loo0 mrn, the permissible variation is to be increased by 0.02 mm for each additional fomm (convex) 3, Local tolerance: 0.02 mm over 500 mm a ,I 1) L =Turning leng
9、th 2) Permissible variation which is referred to a specified length and can be measured at any point. L 3) At the two ends the local tolerance can be twice as large over the length- 4 Continued on pages 2 to 8 Explanations on page 8 Alleinverkauf der Normen durch Beuth Verlag GmbH. Berlin 30 und Kln
10、 1 03.78 Vertr.- Nr. 0106 DIN 8607 engl. Preisgr. Page 2 DIN 8607 Object of test i ng b in transverse direction 3 Geometrical testings Straightness of carriage movement in the horizontal plane or in the plane defined by the axis of the centres and the tool point Parallelism of carriage movement and
11、tailstock guides a in the horizon ta I plane b inthe vertica I plane Diagram a A A 4, s J,=L constant b Test apparatus See01 a a Lupto 1500 mm Dial indicator according to DIN 879 Test mandrel or straight- edge 300 up to 500 mm long b forany turning length Test wire and micro- scope or optical method
12、s Dial indicator according to DIN 879 Test instructions b Place level on measuring bridge (straightedge). For both measurements the level may also be placed on the transverse slide or carriage. 3.1 .I 5.2.1.2.2.1 5.2.1.2.2.2 a Mount test mandrel between centres. Dial indicator on carriage. Stylus be
13、aring in the hori- zontal plane against the test mandrel. Traverse carriage along the test mandrel. b Attach test wire at headstock, pass it over a pulley at the end of the bed and tension with a weight. Microscope on carriage. Line up the test wire at c and d by means of the cross wires of the micr
14、oscope. Traverse car r age along the test wire. a 5.2.3.2.5 or 5.2 -3.2 .I b 5.2.1.3.3 5.2.3.2.3 Dial indicator on carriage; stylus in contact with tailstock sleeve. The tailstock sleeve must be run out to a sufficient distance and locked as under normal working conditions. Traverse carriage and tai
15、lstock jointly over the full length of the bed. 5.4.2.2.5 Variations permissible b 0.04mm/m change in inclination a and b 0.02 mm L up to 500 mm 0.025 mm L over 500 up to 1000 mm If the turning length exceeds 1000 mm, the permissible variation is to be increased by 0.005 mm for each add itiona I 100
16、0 mm, but without exceeding a maximum per missi ble variation of 0.05 mm. measured a 0.04 mm a . b 0.04 mm b . Loca I tolerance: over 500 mm L up to 1500 mm 0.02 mm 0.03 mm over 500 mm L above 1500 mm D IN 8607 Page 3 No G3 testing a Period- ical axial slip of spindle b Cammins of shoulder Run-out o
17、f spindle nose centring taper . G5 Ispindie a at the spindle nose b ata distance equa I to half the maximum turning diameter, subject to a maximum of 500 rnm Diagram -F I a b Test apparatus Dial indicator according to DIN 879 (Auxiliary measure- ment aid) - Dial indicator according to DIN 879 Dial i
18、ndicator accord i ng to DIN 879 Test mandrel with mounting taper Test instructions Dial i ndicqtor a on spindle axis b on spindie shoulder Slowly rotate spindle. In the event of play in the thrust bearings, apply constant force F. The value of F is to be specified by the manufacturer. 5.6.2 5.6.3 Ap
19、ply the dial ndicator at right ingles to the circum- erence of the taper. Slowly rotate spindle. In the event of play n the thrust bearings, ipply constant force t; The value of F is to le specified by the nan ufacturer. 5.6.1 -2.2 Test mandrel in internal taper. Apply dial indicator to circumferenc
20、e of test mandrel. Rotate spindle. Measure at a, then at b. 5.6.1.2.3 Variations permissible a 0.015 mm b 0.02 mm (including periodical axial slip) 0.015 mm a 0.015 mm b 0.05 mrn for a measuring length of 500 mrn measured a b a b Page 4 DI N 8607 Object of testing Paral lei ism if spindle axis with
21、xrriage novement )ver a lengtl ?qual to hal. :he maxi- num turnin! j ia meter, iubject to a naximum f 500 rnm I inthe iorizontal )lane I in the rertical I la ne Parallelism of tailstock sleeve axis withcarriagc movement a in the horizontal plane b inthe vertical plane Parallelism of receiving taper
22、in ta Istock with carriage move ment a in the horizontal plane b in the vertical plane Diagram d .c h Test apparatus Dial indicator according to DIN 879 Test mandrel with mounting taper Dial indicator according to DIN 879 Dial indicator according to DIN 879 Test mandrel with mounting taper Test inst
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN86071976MACHINETOOLSLATHESOFNORMALACCURACYSWINGABOVE800UPTO1600MMACCEPTANCECONDITIONS 机床 旋转 直径 800

链接地址:http://www.mydoc123.com/p-661981.html