1、COMMISSION INTERNA TIONAL E DE LkLAIRAGE INTERNATIONAL COMMISSION ON ILLUMINATION IN TERNA TIONA LE BEL E UCHTUNGSKOMMISSION LIGHTING FOR SPORTS HALLS PUBLICATION CIE No 58 (1983) BUREAU CENTRAL DE LA CIE 52, BOULEVARD MALESHERBES 75008 PARIS - FRANCE COPYRIGHT International Commission on Illuminati
2、onLicensed by Information Handling Services CIE 58 83 IIB 9006345 0002447 240 This rxport has been prepared by CIE Technical Committee 4.4 Sports Lighting. It has been approved by the majority of the Technical Committee and is recommended for study and application. This report is not an Officially A
3、greed CIE Recommendation approved by the National Committees of the Member Countries of the CIE. It should be noted that any recommendation in this report are advisory and not mandatory. The latest CIE Proceedings or CIE Journal should be consulted regarding the current status of this report and pos
4、sible subsequent amendments. Ce rapport a t prepar par le Comit Technique 4.,4 Eclairage pour la Practique des Sports de,la CIE., I1 a et6 approuv par la majorite du Comit Technique et il est recommande pour etude et appl icatiy. Ce rapport nest pas une Recommendation officielle de la CIE, approuve
5、par les Comites Nationaux de. Pays Membres de la CIE. I1 doit gtre not que toute recommandation y figurant est donnee titre de conseil et non dobligation. En ce qui concerne la situation presente de ce Rapport et d, Fencing, Tennis, Table Tennis Box! ng , Wres tl i ng 2.3. LIMITATION OF GLARE 1 s RE
6、CREATIONAL/TRAINING COMPETITION Eh lux Eh lux 300 500 500 750 300 1500 - 30005: 1 Visual performance is reduced by glare which must therefore be limited as far as possible. Some measures for limiting glare may be taken from CIE Publication No. 29 (1975) Guide on Interior Lighting, Chapter 3, Discomf
7、ort Glare. This procedure has been developed for working areas mainly with a horizontal viewing direction and a regular layout of ceiling mounted luminaires. It may be necessary, therefore, to take additional measures for limiting glare in sports halls, depending on the type of sports. For example,
8、glare caused by high brightness light sources in the players field of view at some critical point in the game, may require special attention to the positioning and screening of light sources to avoid this effect. On the other hand, the viewing direction of a sports participant is constantly changing
9、, whereas in working areas, discomfort glare is aggravated by a relatively. fixed viewing position and direction. TABLE 1 : Recommended average hori zontal ser*/i ce i 11 umi nance The illuminance provided in a sports hall, measured lm above the floor, should be designed for the sports with the high
10、est requirements. For halls without windows or where windows are only used for visual contact (e.g. observation windows), the average horizontal illuminance should not be less than 500 lux. 2.4. COLOUR OF LIGHT SOURCES In general, the use of lamps in colour rendering Group 2 according to CIE Publi N
11、o. 29 (1975) Guide on Interior Lighting, Chapter 6, will be acceptable. ati n Where there is a high proportion of daylight, lamps with “intermediate“ or “cool“ colour appearance should be chosen to blend with the natural light. -2- COPYRIGHT International Commission on IlluminationLicensed by Inform
12、ation Handling Services2.5. ARRANGEMENT OF LUMINAIRES Luminaires with tubular fluorescent lamps are preferably arranged parallel to the main viewing direction. Fittings with high pressure discharge lamps can be uniformly distributed over the ceiling. Such luminaires might also provide a proportion o
13、f upward light. Where a suitable roof structure exists, directional lighting can be provided from cat walks, or from trusses over the sports area, or from the sides of the hall. 2.6. RECOMMENDED REFLECTION FACTORS The reflection factors recommended for major surfaces are: Ceiling - 0.6 Walls - 0.3 -
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CIE581983LIGHTINGFORSPORTSHALLSE 运动 场馆 照明 EPDF

链接地址:http://www.mydoc123.com/p-594271.html