CEPT T CS 54-07 E-1982 Analogue Subscriber Line Tests and Measurements《模拟用户线测试和测量》.pdf
《CEPT T CS 54-07 E-1982 Analogue Subscriber Line Tests and Measurements《模拟用户线测试和测量》.pdf》由会员分享,可在线阅读,更多相关《CEPT T CS 54-07 E-1982 Analogue Subscriber Line Tests and Measurements《模拟用户线测试和测量》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 T/CS54-07E Page 1 - Recornmendation TICS 54-07 (Vienna 1982) ANALOGUE SUBSCRIBER LINE TESTS AND MEASUREMENTS Recommendation proposed by Working Group T/No. 11 “Switching and Signalling” (CS) Text of the Recommeridation adopted by the “Telecommunicatiois” Cormiission : “The European Conference of Po
2、stal and Telecommunications Administrations, considesing - that analogue subscriber lines are currently generally used and will continue to be used to a great extent in the - that on the basis of the dened maintenance philosophy, procedures for testing, measuring and monitoring, - that existing prac
3、tice for analogue subscriber iine maintenance shows a considerable variance in solutions; - that system independent equipment, as well as the integration of some or all of these functions into digital local foreseeable future; together with the field of application for subscriber line maintenance, a
4、ll need to be specified; exchanges may be used, O secommends that the members of the CEPT use for new exchanges, and/or system independent test and/or measurement equipment, the procedures for analogue subscriber line tests and measurements set-out below.” GENERAL INTRODUCTION - FELD OF APPLICATION
5、This Recommendation covers the maintenance of an analogue subscriber connection. Referring to the Figure 1 (TICS 54-07), three parts can be recognized in this connection: - the subscriber set or STE (subscriber terminal equipment); - the transmission part of the subscriber connection; - the exchange
6、 terminal (ET). The ET can be situated in a local digital exchange or in a remote multiplexer or concentrator. Special categories of lines (e.g. party lines, analogue subscriber carrier systems, concentrators, service restrictions indicated by the presence of ground on one of the wires, etc.) are no
7、t covered in the present Recommendation. The test and/or measurement procedures to be used in such lines is for further study. anaiogue te lep hon y PART 1: OUTWARD TESTS AND MEASUREMENTS This part of the Recommendation considers only the outward tests and measurements of the subscriber set and the
8、subscriber line. Edition of May 15, 1986 CEPT T/CS*54-07*E 82 232b414 0005180 8 TICS 54-07 E Page 2 1. 1.1. 1.2. 1.3. 1.4. 1.5. 2. 3. 3.1. 3.2. GENERAL REQUIREMENTS In order to adequately perform the tests of the subscriber set and subscriber line, the exchange must be capable of preventing disturbi
9、ng influences from the exchange terminal to the line, e.g. by complete disconnection. It must be possible to connect any subscriber line via an appropriate access to the test equipment, e.g. a metallic path. It should be possible to initiate the tests and/or measurements and to receive the results l
10、ocally or at a remote work position, For some tests and/or measurements, initiation will take place from the subscribers premises. With respect to the line tests and/or measurements, each subscribers line will be in one of the following states : - fault free line; - line not tested; - faulty line. A
11、 faulty line may be blocked or marked. The term blocked means that the line is blocked to calls due to a detected fault. The term marked means that the line has been indicated as faulty because of failure but is not blocked to calls. Only free lines will be able to be tested and/or measured by all t
12、he methods described in this Recommenda- tion. When the line is not tested, the reason why it is not tested will be presented, except if the line is not installed. When the subscriber line is tested or measured without the knowledge of the actual subscriber, the subscriber should be kept as unaware
13、of these actions as possible (e.g. bell-ringing, clicks, etc.). TEST AND/OR MEASUREMENT METHODS Three test and/or measurement methods can be distinguished : A. tests initiated from subscribers premises (on demand, by dialling a special code); B. tests and/or measurements initiated from administratio
14、ns premises (on demand, usually via a man- C. automatic tests (automatic routine tests and/or measurements, automatic tests on a call-by-call basis). The choice of the applied procedure(s) (e.g. omitting the automatic tests on a call-by-call basis) depends on technical and economical considerations
15、that can be different for each Administration according to the structure of the network and the organization of maintenance. It should be in accordance with a general maintenance philosophy. machine interface, e.g. control desk); TESTS INITIATED FROM THE SUBSCRIBERS PREMISES These tests provide main
16、tenance staff with the ability to access a ringback service from the subscribers premises, in order to initiate some tests on the line and the terminal equipment. These tests should also be possible from any point in the local network, by means of a portable telephone set. The following call procedu
17、re could be adopted (needs further study) : - maintenance staff member dials a particular access code on the set to be tested; - the exchange sends back a tone indicating whether the test equipment is available or not; - the successive actions to off-hook and on-hook enable the different tests to be
18、 made. Note: The different test to be made could also be selected by differing access codes, determining individual test or groups of tests. From the subscribers premises, the following tests are implicit in the call procedure: 1. dial performance; 2. multifrequency keying performance; 3. test of be
19、ll functions. Edition of May 15, 1986 TICS 54-07 E Page 3 3.3. The following tests can also be provided optionally: 1. foreign DC and AC voltages; 2. insulation resistance; 3. power supply, current or loop resistance; 4. meter at subscriber?s premises; 5. loop capacitance; 6. quality of speech trans
20、mission (telephonometry); 7. extensive MFPB or dial performance tests. 4. TESTS AND/OR MEASUREMENTS FROM ADMINISTRATION?S PREMISES These detailed tests and/or measurements are initiated from local or remote man-machine terminals. They can be initiated after the examination of the fault reports resul
21、ting from previous automatic routine tests, previous automatic call-by-call tests or on the basis of subscriber complaints. They have priority over automatic routine tests. Lines with a permanent busy condition should be able to be tested and/or measured from Administration?s premises. Where subscri
22、ber co-operation exists, a speech connection is assumed. When tests are being done without subscriber co-operation and the subscriber is making a call attempt, the tests or measurements should be aborted. They should also be aborted, if possible, when an incoming call is made to the subscriber line
23、being tested. In the following, tests and/or measurements from the Administration?s premises are identified. The actual tests to be performed, fault limits, the lines to be tested and the test moment) may be controlled by man-machine-communication. 4.1. Without co-operation at subscriber?s premises:
24、 1. foreign DC voltage : - between a and b - a to ground - b to ground; 2. foreign AC voltage: - between a and b - a to ground - b to ground; 3. insulation resistance: - between a and b - a to ground or to exchange battery - b to ground or to exchange battery; the last two tests of point 3. above ma
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CEPTTCS5407E1982ANALOGUESUBSCRIBERLINETESTSANDMEASUREMENTS 模拟 用户 测试 测量 PDF

链接地址:http://www.mydoc123.com/p-593072.html