BS ISO 7206-13-2016 Implants for surgery Partial and total hip joint prostheses Determination of resistance to torque of head fixation of stemmed femoral components《外科植入物 部分和全髋关节假体.pdf
《BS ISO 7206-13-2016 Implants for surgery Partial and total hip joint prostheses Determination of resistance to torque of head fixation of stemmed femoral components《外科植入物 部分和全髋关节假体.pdf》由会员分享,可在线阅读,更多相关《BS ISO 7206-13-2016 Implants for surgery Partial and total hip joint prostheses Determination of resistance to torque of head fixation of stemmed femoral components《外科植入物 部分和全髋关节假体.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BS ISO 7206-13:2016Implants for surgery Partialand total hip joint prosthesesPart 13: Determination of resistance totorque of head fixation of stemmed femoralcomponentsBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS ISO 7206-13:2016 BRITISH STANDARDNational forewo
2、rdThis British Standard is the UK implementation of ISO 7206-13:2016.The UK participation in its preparation was entrusted toT e c h n i c a l C o m m i t t e e C H / 1 5 0 / 4 , S u r g i c a l I m p l a n t s - B o n e a n d J o i n tReplacements.A list of organizations represented on this committ
3、ee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2016.Published by BSI Standards Limited 2016ISBN 978 0 580 87687 5ICS 11.040.40Com
4、pliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 July 2016.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS ISO 7206-13:2016 ISO 2016Imp
5、lants for surgery Partial and total hip joint prostheses Part 13: Determination of resistance to torque of head fixation of stemmed femoral componentsImplants chirurgicaux Prothses partielles et totales de larticulation de la hanche Partie 13: Dtermination de la rsistance au couple de la fixation de
6、s ttes des tiges fmoralesINTERNATIONAL STANDARDISO7206-13First edition2016-07-01Reference numberISO 7206-13:2016(E)BS ISO 7206-13:2016ISO 7206-13:2016(E)ii ISO 2016 All rights reservedCOPYRIGHT PROTECTED DOCUMENT ISO 2016, Published in SwitzerlandAll rights reserved. Unless otherwise specified, no p
7、art of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member
8、body in the country of the requester.ISO copyright officeCh. de Blandonnet 8 CP 401CH-1214 Vernier, Geneva, SwitzerlandTel. +41 22 749 01 11Fax +41 22 749 09 47copyrightiso.orgwww.iso.orgBS ISO 7206-13:2016ISO 7206-13:2016(E)Foreword ivIntroduction v1 Scope . 12 Normative references 13 Terms and def
9、initions . 14 Principle 15 Apparatus . 16 Procedure. 26.1 Test specimen and sample size . 26.2 Assembly of test specimen (installation) . 26.3 Head fixation . 26.4 Torque of head fixation 36.5 Performance criteria 36.6 Test report . 37 Disposal of test specimens . 4Bibliography 6 ISO 2016 All rights
10、 reserved iiiContents PageBS ISO 7206-13:2016ISO 7206-13:2016(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical com
11、mittees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
12、 International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for th
13、e different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. I
14、SO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received (see www.iso.org/patents). Any trade name used in this doc
15、ument is information given for the convenience of users and does not constitute an endorsement.For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment, as well as information about ISOs adherence to the WTO principles in the Technical Barriers to Trad
16、e (TBT) see the following URL: Foreword - Supplementary informationThe committee responsible for this document is ISO/TC 150, Implants for surgery, Subcommittee SC 4, Bone and joint replacements.ISO 7206 consists of the following parts, under the general title Implants for surgery Partial and total
17、hip joint prostheses: Part 1: Classification and designation of dimensions Part 2: Articulating surfaces made of metallic, ceramic and plastics materials Part 4: Determination of endurance properties of stemmed femoral components Part 6: Endurance properties testing and performance requirements of n
18、eck region of stemmed femoral components Part 10: Determination of resistance to static load of modular femoral heads Part 12: Deformation test method for acetabular shells Part 13: Determination of resistance to torque of head fixation of stemmed femoral componentsiv ISO 2016 All rights reservedBS
19、ISO 7206-13:2016ISO 7206-13:2016(E)IntroductionSome designs of stemmed femoral components of total hip joint prostheses comprise a stem/neck component and a bearing head component, which is commonly in the form of a partial sphere incorporating a female fixation feature for attachment to the neck of
20、 the stem. Such heads are generally produced using metal or ceramic material. It is important that after assembly, whether by the manufacturer or by the surgeon in the operating theatre, the head subsequently remains immobile on the neck, because movement of a metal or a ceramic femoral head compone
21、nt on a metal stem/neck component will cause the metal components to wear, while metal-on-metal movement may lead to severe fretting corrosion (see Reference 1).It is essential, therefore, that the strength of the fixation between the head and the neck is sufficient to withstand the torque likely to
22、 be transmitted through the prosthesis in use. The maximum torque applied to the interface connection depends on several design, material, and manufacturing specific parameters, e.g. pairing of bearing materials, bearing diameter, and clearance, surface finish, etc. (see Reference 2).The locking str
23、ength of the interface connection depends on several design, material, and manufacturing specific parameters for the taper geometry of the mating components, as taper angle and tolerances, taper clearance, surface finish, etc. In consequence, the torsional locking strength of nominal identical taper
24、 fixations might vary significantly (see Reference 3) and needs to be determined prior to clinical use.Clinical failure of taper connections is related to particle generation by interface micromotion, fretting, and fatigue failure (see Reference 4). Torsional interface stability is essential for sta
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO7206132016IMPLANTSFORSURGERYPARTIALANDTOTALHIPJOINTPROSTHESESDETERMINATIONOFRESISTANCETOTORQUEOFHEADFIXATIONOFSTEMMEDFEMORALCOMPONENTS

链接地址:http://www.mydoc123.com/p-587942.html