BS ISO 5834-1-2005 Implants for surgery - Ultra-high-molecular-weight polyethylene - Powder form《外科植入物 超高分子量聚乙烯 粉剂型》.pdf
《BS ISO 5834-1-2005 Implants for surgery - Ultra-high-molecular-weight polyethylene - Powder form《外科植入物 超高分子量聚乙烯 粉剂型》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 5834-1-2005 Implants for surgery - Ultra-high-molecular-weight polyethylene - Powder form《外科植入物 超高分子量聚乙烯 粉剂型》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS ISO 5834-1:2005 Incorporating corrigendum no. 1 Implants for surgery Ultra-high- molecular-weight polyethylene Part 1: Powder form ICS 11.040.40 BS ISO 5834-1:2005 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 10 Novembe
2、r 2005 BSI 2008 ISBN 978 0 580 60920 6 National foreword This British Standard is the UK implementation of ISO 5834-1:2005, incorporating corrigendum May 2007. It supersedes BS ISO 5834-1:1998 which is withdrawn. The start and finish of text introduced or altered by corrigendum is indicated in the t
3、ext by tags. Text altered by ISO corrigendum May 2007 is indicated in the text by . The UK participation in its preparation was entrusted by Technical Committee CH/150, Implants for surgery, to Subcommittee CH/150/1, Materials (for surgical implants). A list of organizations represented on this subc
4、ommittee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal obligations. Amendments/corrigenda is
5、sued since publication Date Comments 31 January 2008 Implementation of ISO corrigendum May 2007 Reference number ISO 5834-1:2005(E)INTERNATIONAL STANDARD ISO 5834-1 Third edition 2005-06-01 Implants for surgery Ultra-high- molecular-weight polyethylene Part 1: Powder form Implants chirurgicaux Polyt
6、hylne trs haute masse molculaire Partie 1: Produits sous forme de poudre BS ISO 5834-1:2005ii BS ISO 5834-1:2005iii Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standa
7、rds is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also tak
8、e part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is
9、 to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibilit
10、y that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 5834-1 was prepared by Technical Committee ISO/TC 150, Implants for surgery, Subcommittee SC 1, Materials. This third edition cancels
11、 and replaces the second edition (ISO 5834-1:1998), which has been technically revised. ISO 5834 consists of the following parts, under the general title Implants for surgery Ultra-high-molecular- weight polyethylene: Part 1: Powder form Part 2: Moulded forms Part 3: Accelerated ageing methods Part
12、4: Oxidation index measurement method Part 5: Morphology assessment method blank 1 Implants for surgery Ultra-high-molecular-weight polyethylene Part 1: Powder form 1 Scope This part of ISO 5834 specifies the requirements and corresponding test methods for moulding materials in powder form made from
13、 ultra-high-molecular-weight polyethylene (UHMWPE) for use in the manufacture of surgical implants. It is not applicable to finished products. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cite
14、d applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 1628-3, Plastics Determination of the viscosity of polymers in dilute solution using capillary viscometers Part 3: Polyethylenes and polypropylenes ISO 3451-1, Plastics Determinat
15、ion of ash Part 1: General methods ISO 11542-1, Plastics Ultra-high-molecular-weight polyethylene (PE-UHMW) moulding and extrusion materials Part 1: Designation system and basis for specifications ISO 11542-2, Plastics Ultra-high-molecular-weight polyethylene (PE-UHMW) moulding and extrusion materia
16、ls Part 2: Preparation of test specimens and determination of properties DIN 53474, Testing of plastics, rubber and elastomers Determination of the chlorine content (Wickbold- combustion) 3 Terms and definitions For the purposes of this document, the terms and definitions given in ISO 11542-1 and IS
17、O 11542-2 apply. 4 Classification, designation and coding The material shall be classified as Type 1, Type 2 or Type 3 as defined by the flow properties given in Clause 6 and the ash/trace element contents given in 7.1. BS ISO 5834-1:20052 5 Manufacturing requirements The material shall consist of a
18、 homopolymer prepared by the polymerization of ethylene. The powdered material supplied for each order shall be identified by lot numbers. NOTE “Lot” refers to the material for which testing has been carried out and for which discrete records are kept. 6 Flow properties Flow properties shall be dete
19、rmined by measuring either elongation stress or viscosity number. When measured using the appropriate test method, as defined in Table 1, the minimum value of either the elongational stress or the viscosity number shall exceed the relevant value given in Table 1 for each type of material. Table 1 Fl
20、ow properties Minimum values Property Units Type 1 Types 2 and 3 Test method according to subclause Elongational stress MPa 0,2 0,42 8.1 Viscosity number ml/g 2,000 3,200 8.2 NOTE Compliance with either of the above test requirements indicates satisfactory polymer molecular mass. 7 Limits of contami
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO583412005IMPLANTSFORSURGERYULTRAHIGHMOLECULARWEIGHTPOLYETHYLENEPOWDERFORM 外科 植入 超高 分子量 聚乙烯 粉剂 PDF

链接地址:http://www.mydoc123.com/p-587629.html