BS EN 60601-1-9-2008 Medical electrical equipment - Part 1-9 General requirements for basic safety and essential performance - Collateral standard - Requirements for environmentall.pdf
《BS EN 60601-1-9-2008 Medical electrical equipment - Part 1-9 General requirements for basic safety and essential performance - Collateral standard - Requirements for environmentall.pdf》由会员分享,可在线阅读,更多相关《BS EN 60601-1-9-2008 Medical electrical equipment - Part 1-9 General requirements for basic safety and essential performance - Collateral standard - Requirements for environmentall.pdf(34页珍藏版)》请在麦多课文档分享上搜索。
1、Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 12/09/2008 02:48, Uncontrolled Copy, (c) BSIg49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58s
2、afety and essential performance Collateral Standard: Requirements for environmentally conscious designICS 11.040.01; 13.020.99Medical electrical equipment Part 1-9: General requirements for basic BRITISH STANDARDBS EN 60601-1-9:2008BS EN 60601-1-9:2008Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STAN
3、DARDS, 12/09/2008 02:48, Uncontrolled Copy, (c) BSIThis British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 July 2008 BSI 2008ISBN 978 0 580 54461 3Amendments/corrigenda issued since publicationDate CommentsThis publication does not purport to incl
4、ude all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.National forewordThis British Standard is the UK implementation of EN 60601-1-9:2008. It is identical to IEC 60601-1-9:20
5、07. The UK participation in its preparation was entrusted by Technical Committee CH/62, Electromedical equipment in medical practice, to Subcommittee CH/62/1, Common aspects of electrical equipment used in medical practice.A list of organizations represented on this committee can be obtained on requ
6、est to its secretary.EUROPEAN STANDARD EN 60601-1-9 NORME EUROPENNE EUROPISCHE NORM April 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B -
7、 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60601-1-9:2008 E ICS 11.040; 13.020 English version Medical electrical equipment - Part 1-9: General requirements for basic safety and essential performance - Col
8、lateral Standard: Requirements for environmentally conscious design (IEC 60601-1-9:2007) Appareils lectromdicaux - Partie 1-9: Exigences gnrales pour la scurit de base et les performances essentielles - Norme collatrale: Exigences pour une conception co-responsable (CEI 60601-1-9:2007) Medizinische
9、elektrische Gerte - Teil 1-9: Allgemeine Festlegungen fr die Sicherheit einschlielich der wesentlichen Leistungsmerkmale - Ergnzungsnorm: Anforderungen zur Reduzierung von Umweltauswirkungen (IEC 60601-1-9:2007) This European Standard was approved by CENELEC on 2008-04-16. CENELEC members are bound
10、to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Cent
11、ral Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same st
12、atus as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway,
13、Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 12/09/2008 02:48, Uncontrolled Copy, (c) BSIForeword The text of document 62A/571/FDIS, future edition 1 of IEC 60601-1-9, prepared by SC 62A, Comm
14、on aspects of electrical equipment used in medical practice, of IEC TC 62, Electrical equipment in medical practice, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60601-1-9 on 2008-04-16. The following dates were fixed: latest date by which the EN has to be impleme
15、nted at national level by publication of an identical national standard or by endorsement (dop) 2009-02-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-05-01 This European Standard has been prepared under a mandate given to CENELEC by the Europe
16、an Commission and the European Free Trade Association and covers essential requirements of EC Directive 93/42/EEC. See Annex ZZ. This European Standard constitutes a collateral standard to EN 60601-1:2006, hereafter referred to as the general standard. In the 60601 series of publications, collateral
17、 standards specify general requirements for safety applicable to a subgroup of MEDICAL ELECTRICAL EQUIPMENT (e.g. radiological equipment); or a specific characteristic of all MEDICAL ELECTRICAL EQUIPMENT, not fully addressed in the general standard (e.g. alarm systems). In this collateral standard t
18、he following print types are used: requirements and definitions: roman type; test specifications: italic type; informative material appearing outside of tables, such as notes, examples and references: in smaller type. Normative text of tables is also in a smaller type; TERMS DEFINED IN CLAUSE 3 OF T
19、HE GENERAL STANDARD, IN THIS COLLATERAL STANDARD OR AS NOTED: SMALL CAPITALS. In referring to the structure of this standard, the term “clause” means one of the four numbered divisions within the table of contents, inclusive of all subdivisions (e.g. Clause 4 includes Subclauses 4.1, 4.2, etc.); “su
20、bclause” means a numbered subdivision of a clause (e.g. 4.1, 4.5 and 4.5.1 are all subclauses of Clause 4). References to clauses within this standard are preceded by the term “Clause” followed by the clause number. References to subclauses within this standard are by number only. In this standard,
21、the conjunctive “or” is used as an “inclusive or” so a statement is true if any combination of the conditions is true. BS EN 60601-1-9:2008 2 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 12/09/2008 02:48, Uncontrolled Copy, (c) BSIThe verbal forms used in this standard conform to usage des
22、cribed in Annex H of the ISO/IEC Directives, Part 2. For the purposes of this standard, the auxiliary verb “shall” means that compliance with a requirement or a test is mandatory for compliance with this standard; “should” means that compliance with a requirement or a test is recommended but is not
23、mandatory for compliance with this standard; “may” is used to describe a permissible way to achieve compliance with a requirement or test. Clauses, subclauses and definitions for which a rationale is provided in informative Annex A are marked with an asterisk (*). Annexes ZA and ZZ have been added b
24、y CENELEC. _ Endorsement notice The text of the International Standard IEC 60601-1-9:2007 was approved by CENELEC as a European Standard without any modification. _ BS EN 60601-1-9:2008 3 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 12/09/2008 02:48, Uncontrolled Copy, (c) BSICONTENTS INTR
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN60601192008MEDICALELECTRICALEQUIPMENTPART19GENERALREQUIREMENTSFORBASICSAFETYANDESSENTIALPERFORMANCECOLLATERALSTANDARDREQUIREMENTSFORENVIRONMENTALLPDF

链接地址:http://www.mydoc123.com/p-575949.html