BS 5482-2-1977 Domestic butane- and propane-gas-burning installations - Installations in caravans and non-permanent dwellings《家用丁烷和丙烷燃气装置 旅居车与非永久性住宅中的装置》.pdf
《BS 5482-2-1977 Domestic butane- and propane-gas-burning installations - Installations in caravans and non-permanent dwellings《家用丁烷和丙烷燃气装置 旅居车与非永久性住宅中的装置》.pdf》由会员分享,可在线阅读,更多相关《BS 5482-2-1977 Domestic butane- and propane-gas-burning installations - Installations in caravans and non-permanent dwellings《家用丁烷和丙烷燃气装置 旅居车与非永久性住宅中的装置》.pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 5482-2: 1977 Reprinted, incorporating Amendments No. 1 to 5 inclusive Code of practice for Domestic butane- and propane- gas-burning installations Part 2: Installations in caravans and non-permanent dwellings formerly CP 339-2 UDC 728.7:64.06:696.2:683.8/.9:662.767.3/.4 ICS 43.10
2、0 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW CONFIRMED FEBRUARY 1988BS 5482-2:1977 This British Standard, having been prepared under the direction of the Gas Standards Committee, was published under the authority of the Executive Board on 31 August 1977 BSI 06-2001 First
3、published, as CP 339-2, November 1956 First revision, as BS 5482-2, August 1977 The following BSI references relate to the work on this standard: Committee reference GSE/31 Draft for comment 75/40000 DC ISBN 0 580 09774 9 Cooperating organizations The Gas Standards Committee, under whose direction t
4、his British Standard was prepared, consists of representatives from the following Government departments and professional and industrial organizations: British Gas Corporation* Department of Energy Department of the Environment* Heating and Ventilating Contractors Association Institution of Gas Engi
5、neers Institution of Heating and Ventilating Engineers Liquefied Petroleum Gas Industry Technical Association (UK)* National Association of Plumbing, Heating and Mechanical Services Contractors Society of British Gas Industries* Water-tube Boilermakers Association The organizations marked with an as
6、terisk in the above list, together with the following, were directly represented on the committee entrusted with the preparation of this British Standard. British Compressed Gases Association Chief and Assistant Chief Fire Officers Association Consumer Standards Advisory Committee Department of Trad
7、e Fire Offices Committee Fire Protection Association Home Office Institution of Fire Engineers National Caravan Council Ltd. Ship and Boat Builders National Federation Amendments issued since publication Amd. No. Date of issue Comments 2736 September 1978 4000 May 1982 5051 June 1986 5204 March 1987
8、 12046 June 2001 Indicated by a sidelineBS 5482-2:1977 BSI 06-2001 i Contents Page Cooperating organizations Inside front cover Foreword iii Section 1. General 1S c o p e 1 2 References 1 3 Definitions 1 Section 2. Materials, components and appliances 4M a t e r i a l s 3 5 Components 4 6 Selection
9、of appliances 4 Section 3. Installation design 7 Basic layout of supply system 7 8 Cylinder requirement design considerations 7 9 Installation design considerations 7 10 High pressure stage design considerations 9 11 Low pressure stage design considerations 10 12 Siting of appliances 11 13 Flue desi
10、gn considerations 11 14 Ventilation design considerations 12 Section 4. Installation requirements 15 Installation of unions, joints, sectional cocks and valves 15 16 Installation of pipework 15 17 Installation of cocks 16 18 Installation of pressure regulators 16 19 Installation of appliances 16 Sec
11、tion 5. Inspection, testing and consumer instructions 20 Inspection and testing of new installations 19 21 Consumer instructions 19 Appendix A The safe use of LPG in caravans and non-permanent dwellings 19 Appendix B Testing of low pressure stage of installation 21 Figure 1 Guide to heating requirem
12、ents in touring caravans 22 Figure 2 Guide to heating requirements in residential caravans 23 Figure 3 High pressure stage manifolds 24 Figure 4 Pipe sizing chart 25 Figure 5 Diagrammatic circuit indicating butane terminal pressure, 4.25 m caravan with full load 26 Figure 6 Diagrammatic circuit indi
13、cating butane terminal pressure, 5.5 m caravan with full load 26 Figure 7 Diagrammatic circuit indicating butane terminal pressure, 6.75 m caravan with full load 27 Figure 8 Diagrammatic circuit indicating butane terminal pressure, 9.5 m caravan with full load 27 Figure 9 Diagrammatic circuit indica
14、ting butane terminal pressure, 12 m caravan with full load 28 Figure 10 Installation test apparatus 28 Figure 11 Bubble leak indicator 29BS 5482-2:1977 ii BSI 06-2001 Page Figure 12 Standard nozzle pressure point adaptor and washer for 8 mm ( in) i.d. flexible tubing 29 Table 1 Appliance rates, numb
15、er of cylinders and cylinder offtakes 8 Publications referred to 30 5 16 BS 5482-2:1977 BSI 06-2001 iii Foreword This British Standard code of practice is a revision of CP 339-2:1956, and in its preparation the opportunity has been taken to incorporate propane gas requirements and to express values
16、in SI units. In line with the policy to bring codes of practice into the numbering series for British Standards, this code is being published under the number BS 5482. Particular care has been taken in this standard in the section on ventilation with the object of overcoming special problems with ve
17、ntilation of motor caravans. Reference should be made to the current requirements of the Motor Vehicles (Construction and Use) Regulations as applying to caravans, motor caravans and mobile catering units, etc. As a code of practice, this British Standard takes the form of guidance and recommendatio
18、ns. It should not be quoted as if it were a specification and particular care should be taken to ensure that claims of compliance are not misleading. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correc
19、t application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i to iv, pages 1 to 31 and a back cover. The BSI copyright notice displayed in this document indicates whe
20、n the document was last issued. Sidelining in this document indicates the most recent changes by amendment.iv blankBS 5482-2:1977 BSI 06-2001 1 Section 1. General 1 1 Scope This Part of BS 5482 deals with the installation in caravans and non-permanent dwellings, mobile catering or other non-industri
21、al mobile units of systems using liquefied petroleum gases whether from cylinders or bulk supply at a pressure of 28 mbar 1) , for commercial butane and at 37 mbar for commercial propane. It gives guidance on the selection of materials, components and appliances, on design considerations, on install
22、ation requirements, on inspection and testing and on consumer instructions. Appendix A contains basic user guidance on safe practice for inclusion in the consumers manual. This standard does not cover the installation on site of bulk supplies of LPG, for which guidance is given in Health and Safety
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS548221977DOMESTICBUTANEANDPROPANEGASBURNINGINSTALLATIONSINSTALLATIONSINCARAVANSANDNONPERMANENTDWELLINGS

链接地址:http://www.mydoc123.com/p-545124.html