BS 5482-1-2005 Code of practice for domestic butane- and propane-gas-burning installations - Installations at permanent dwellings residential park homes and commercial premises wit.pdf
《BS 5482-1-2005 Code of practice for domestic butane- and propane-gas-burning installations - Installations at permanent dwellings residential park homes and commercial premises wit.pdf》由会员分享,可在线阅读,更多相关《BS 5482-1-2005 Code of practice for domestic butane- and propane-gas-burning installations - Installations at permanent dwellings residential park homes and commercial premises wit.pdf(54页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 5482-1:2005 Code of Practice for domestic butane- and propane-gas-burning installations Part 1: Installations at permanent dwellings, residential park homes and commercial premises, with installation pipework sizes not exceeding DN 25 for steel and DN 28 for corrugated stainless
2、steel or copper ICS 91.140.40; 97.100.20 BS 5482-1:2005 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 20 January 2005 BSI 20 January 2005 First published as CP 339 Part 1 November 1956 and as CP 338 October 1957 Second edition as BS 5482 pa
3、rt 1 January 1979 Third edition January 1994 Fourth edition November 2004 The following BSI references relate to the work on this British Standard: Committee reference GSE/31 Draft for Comment 00/716887 DC ISBN 0 580 44747 2 Committees responsible for this British Standard The preparation of this Br
4、itish Standard was entrusted to Technical Committee GSE/31, Installations using Neat LPG, upon which the following bodies were represented: British Marine Federation British Waterways Board Caravan Club Consumer Policy Committee of BSI CORGI DTI Standards and Technical Regulations Directorate HSE In
5、stitution of Gas Engineers LP Gas Association National Caravan Council Limited Society of British Gas Industries Society of Motor Manufacturers and Traders Limited Amendments issued since publication Amd. No Date CommentsBS 5482-1:2005 BSI 20 January 2005 i Contents Committees responsible Inside fro
6、nt cover Foreword ii 1S c o p e 1 2 Normative references 1 3T e r m s a n d d e f i n i t i o n s 3 4 Exchange of information and installation planning 6 5M a t e r i a l s 6 6V a l v e s 7 7 Regulators 7 8J o i n t s 7 9 Corrosion 8 10 Selection of appliances 9 11 LPG supply arrangements 10 12 Inst
7、allation 18 13 Inspection, testing and user instructions 35 Annex A (normative) Gas soundness testing of LPG service pipework, installation pipework, and appliances 36 Annex B (informative) Guide for sizing gas supply pipes 45 Annex C (informative) Model emergency action notice or leaflet for users
8、of LPG 48 Bibliography 49 Figure 1 Thread wrapping method 8 Figure 2 Cylinder Location 12 Figure 3 Typical 4 47 kg cylinder installation 14 Figure 4 Use of temporary electrical continuity bonding connector 19 Figure 5 Pipe joists 20 Figure 6 Typical examples of buried pipes 21 Figure 7 Typical examp
9、les of pipes in masonry and timber frame walls 23 Figure 8 Typical installation pipework in multi-storey buildings containing flats or maisonettes 29 Figure 9 Position of mains equipontential bond (electrical cross-bonding) 33 Figure A.1 Butane cylinder installations 43 Figure A.2 Propane cylinder i
10、nstallations 44 Figure A.3 Multiple propane cylinder installations 44 Figure A.4 Bulk tank installations (service pipework at low pressure) 44 Figure A.5 Bulk tank installations (service pipework at intermediate pressure) 45 Figure B.1 Example calculation 46 Table 1 Conversion of heat inputs (kW) to
11、 gravimetric calorific value (kg/h) 10 Table 2 Recommended off-takes for temperature climates 10 Table 3 Pipe sizing 16 Table 4 Equivalent lengths of pipe for fittings 17 Table 5 Free area of ventilation openings 27 Table 6 Maximum interval between pipe supports 31 Table A.1 Permissible pressure dro
12、p for test with appliances connected and LPG supplied by cylinder(s) or bulk tank installation pipework 43 Table A.2 Permissible pressure drop for test with appliances connected and propane supplied from a bulk tank 43 Table B.1 Typical appliance gas rates 46 Table B.2 Sizing results 47BS 5482-1:200
13、5 ii BSI 20 January 2005 Foreword This Part of BS 5482 has been prepared by Technical Committee GSE/31. It supersedes BS 5482-1:1994 which is withdrawn, and partially supersedes BS 5482-2:1977. It has been revised to take into account current technology and practice. Legislation requires persons car
14、rying out work to have the required competence. The Gas Safety (Installation and Use) Regulations 1, 2 require any “work” on gas appliances, including their installation, that falls within their scope (i.e. most work outside of factories) to be carried out by a business which is a “member of a class
15、 of persons” approved for the time being by the Health and Safety Executive (HSE). NOTE At the time of publication, the body with HSE approval to operate and maintain a register of businesses who are “members of a class of persons” is the Council for Registered Gas Installers (CORGI). Thus it is ess
16、ential that all business or self employed gas fitters should be registered with CORGI. Guidance on the individual competency required for gas work is given in the Health and Safety Commissions Approved Code of Practice (ACOP) 3. As a code of practice, this British Standard takes the form of guidance
17、 and recommendations. It should not be quoted as if it were a specification and particular care should be taken to ensure that claims of compliance are not misleading. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct appli
18、cation. Compliance with a British Standard does not of itself confer immunity from legal obligations. Attention is drawn to the following statutory regulations: The Health and Safety at Work Act 1974. Gas Safety (Installation and Use) Regulations 1998 (SI 2451) 1. Gas Safety (Installation and Use) R
19、egulations (Northern Ireland) 1997 (SI 194) 2. Building Regulations 1991 (SI 2768) (as amended) 4. Building Standards (Scotland) Regulations 1990 (SI 2179) (as amended) 5. Building Regulations (Northern Ireland) 1990 (SR 59) (as amended) 6. NOTE 4, 5 and 6 do not apply to residential park homes. Sum
20、mary of pages This document consists of a front cover, an inside front cover, pages i and ii, pages 1 to 49 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued.BS 5482-1:2005 BSI 20 January 2005 1 1 Scope This Part of BS 5482 gives guidan
21、ce and recommendations for the installation of liquefied petroleum gas (LPG) supply systems at permanent dwellings, including residential park homes, and small commercial premises, with installation pipework sizes not exceeding DN 25 for steel and DN 28 for corrugated stainless steel or copper. It a
22、pplies to systems using either commercial propane from cylinders or bulk supply at a pressure of 37 mbar, or commercial butane from cylinders at a pressure of 28 mbar. It makes recommendations on the selection of materials and components, on design considerations, on installation, on inspection and
23、testing and on user instructions. NOTE 1 Gas storage and distribution systems for multiple consumers are outside the scope of this standard. This standard does not cover the installation requirements of bulk tanks supplying LPG, for which guidance is given in LPGA Code of Practice 1, Parts 1, 2, and
24、 4.7. Appliances incorporating their own gas supply, such as mobile heaters, are not considered to be part of the installation and are thus outside the scope of this standard. NOTE 2 It is recognized that this standard may be referred to for LPG installations other than those concerned with domestic
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS548212005CODEOFPRACTICEFORDOMESTICBUTANEANDPROPANEGASBURNINGINSTALLATIONSINSTALLATIONSATPERMANENTDWELLINGSRESIDENTIALPARKHOMESANDCOMMERCIALPREMISESWITPDF

链接地址:http://www.mydoc123.com/p-545123.html