BS 4274-1-2003 Visual acuity test types - Test charts for clinical determination of distance visual acuity - Specification《视力检测方式 视力临床测定用检测表规范》.pdf
《BS 4274-1-2003 Visual acuity test types - Test charts for clinical determination of distance visual acuity - Specification《视力检测方式 视力临床测定用检测表规范》.pdf》由会员分享,可在线阅读,更多相关《BS 4274-1-2003 Visual acuity test types - Test charts for clinical determination of distance visual acuity - Specification《视力检测方式 视力临床测定用检测表规范》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 4274-1:2003 Visual acuity test types Part 1: Test charts for clinical determination of distance visual acuity Specification ICS 11.040.70 BS 4274-1:2003 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 13 January 2003 BSI 1
2、3 January 2003 First published 26 January 1968 This revision 13 January 2003 The following BSI references relate to the work on this British Standard Committee reference CH/78/6 Draft for comment 00/560371/DC ISBN 0 580 40644 X Committees responsible for this British Standard The preparation of this
3、 British Standard was entrusted to Technical Committee CH/78/6, Ophthalmic Instruments, upon which the following bodies were represented: Association of British Dispensing Opticians BMA College of Optometrists DoH Medical Devices Agency Federation of Ophthalmic and Dispensing Opticians Federation of
4、 Manufacturing Opticians Flat Glass Manufacturers Association Institute of Mechanical Engineers Medical sterile Products Association Optic (UK) Royal College of Ophthalmologists Amendments issued since publication Amd. No. Date CommentBS 4274-1:2003 BSI 13 January 2003 i Contents Page Committees res
5、ponsible Inside front cover Foreword ii 1S c o p e 1 2 Normative references 1 3T e r m s a n d d e f i n i t i o n s 1 4 Requirements 2 5 Environmental conditions 4 6 Electrical safety 5 7L a b e l l i n g 5 Annex A (informative) Conversion of different visual acuity notations 6 Annex B (normative)
6、Letter formats 7 Bibliography 9 Figure B.1 Letter formats 7 Table 1 Range of letter sizes, heights and number of letters per line 3 Table 2 Conditions in use 4 Table 3 Storage conditions 4 Table 4 Transport conditions 4 Table A.1 Conversion of different visual acuity notations 6BS 4274-1:2003 ii BSI
7、 13 January 2003 Foreword This part of BS 4274, which has been prepared for clinical use by Technical Committee CH/78, supersedes BS 4274-1:1968, which is withdrawn. The other parts of BS 4274, which are for non-clinical purposes, are: Part 2: Specification for Landolt ring optotype for non-clinical
8、 purposes (BS EN ISO 8596); Part 3: Method for correlating optotypes used for non-clinical purposes (BS EN ISO 8597). This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does no
9、t in itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i to ii, pages 1 to 9 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued.BS 4274-1:2003 BSI 13 Janua
10、ry 2003 1 Introduction This British Standard utilizes the logMAR notation (logarithm of the minimum angle of resolution) as opposed to the traditional Snellen notation. Use of the logMAR notation facilitates analysis of visual acuity scores, and changes in such scores, more effectively than other no
11、tations because equal linear steps on the logMAR scale represent equal ratios in the standard size sequence. This minimum standard, which in itself does not represent a full logMAR chart, is intended as a stepped approach to the goal of the introduction of a full logMAR chart. This British Standard
12、takes into account the need for these charts to fit into existing hardware/test cabinets. The physical size of a full logMAR chart would exclude this possibility. Nevertheless, although a full chart exceeds the minimum requirements of this British Standard, this British Standard does not preclude th
13、e use of a full chart. 1 Scope This Part of BS 4274 specifies minimum requirements for test charts and test types employing upright sans-serif capital letters for use in the clinical determination of distance visual acuity. NOTE Unless otherwise indicated by the context, the word “letter” includes,
14、in any orientation, the single letter (Landolt or broken ring) and the single letter (illiterate ). This Part of BS 4274 is primarily intended for clinical measurements but may be used for other purposes such as screening, certification and licensing. It is not applicable to chart projectors, charts
15、 or types designed for specialized use (e.g. crowding symbols, lower case letters, isolated letters, low vision evaluation and contrast sensitivity testing). NOTE This British Standard makes no reference to surrounding luminance because this relates to the conditions in the consulting room or clinic
16、 itself and this is outside the Scope of this British Standard. Nevertheless, the level of surrounding luminance can seriously affect the visual acuity scores obtained, for example, by producing glare or excessive contrast. Attention, therefore, should be paid to the level of surrounding luminance w
17、hen installing and utilizing these test charts. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document applies. BS EN
18、 60601-1:1990, Medical electrical equipment Part 1: General requirements for safety. BS ISO 9022-2:1994, Optics and optical instruments Environmental test methods Part 2: Cold, heat, humidity. BS ISO 9022-3:1994, Optics and optical instruments Environmental test methods Part 3: Mechanical stress 3 T
19、erms and definitions For the purposes of this Part of BS 4274, the following terms and definitions apply. 3.1 Landolt ring character in the form of a letter in any one of the orientations described in 4.9 3.2 letter size distance, measured in metres, at which the height of the letter subtends an ang
20、le of five minutes of arc, expressed as the number only 3.3 limb constituent component of a letter, which may be straight or curved 3.4 line row of lettersBS 4274-1:2003 2 BSI 13 January 2003 3.5 logMAR log minimum angle of resolution logarithm to base 10 of the smallest visual angle (expressed in m
21、inutes of arc) that can be resolved by the subject 3.6 luminance contrast the ratio: 3.7 Snellen notation fraction in which the numerator indicates the test distance, expressed in metres, and the denominator indicates the distance, expressed in metres, at which the limb width of the letter subtends
22、one minute of arc and the letter size subtends five minutes of arc 3.8 test chart test type (non-preferred) optotype (non-preferred) presentation of letters of graduated sizes for the purpose of determining distance visual acuity NOTE The presentation may be by means of a printed chart, projection,
23、electronic display or other means. 3.9 unit length linear distance subtending one minute of arc at the distance indicated by the letter size NOTE This equates to of the height of the letter. 3.10 visual angle angle subtended by the unit length of the letter at the testing distance. 3.11 5 5 letter u
24、pright letter which is capable of being framed tangentially by a square, 5 unit lengths in height and width 4 Requirements 4.1 Range of letter sizes The minimum range of letter sizes shall be from logMAR 0.1 to logMAR 1.0. The minimum graduation of letter sizes shall be in not more than 0.1 logMAR s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS427412003VISUALACUITYTESTTYPESTESTCHARTSFORCLINICALDETERMINATIONOFDISTANCEVISUALACUITYSPECIFICATION

链接地址:http://www.mydoc123.com/p-544266.html