BS 3907-5-1966 Methods for the analysis of magnesium and magnesium alloys - Determination of manganese in magnesium and magnesium alloys (photometric-periodate method) (low content.pdf
《BS 3907-5-1966 Methods for the analysis of magnesium and magnesium alloys - Determination of manganese in magnesium and magnesium alloys (photometric-periodate method) (low content.pdf》由会员分享,可在线阅读,更多相关《BS 3907-5-1966 Methods for the analysis of magnesium and magnesium alloys - Determination of manganese in magnesium and magnesium alloys (photometric-periodate method) (low content.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS3907-5: 1966 Method for The determination of manganese in magnesium and magnesium alloys (Photometric periodate method) (Low contents) Methods for the analysis of magnesium and magnesium alloysBS3907-5:1966 This BritishStandard, having been approved by the Non-ferrous Metals Indus
2、try Standards Committee and endorsed by the Chairman oftheEngineering Divisional Council, was published undertheauthority of the GeneralCouncil on 17March1966 BSI12-1999 The following BSI references relate to the work on this standard: Committee references NFE/23 and NFE/23/4 Draft for comment D65/1
3、421 ISBN 0 580 04421 1 Co-operating organizations The Non-ferrous Metals Industry Standards Committee, under whose supervision this BritishStandard was prepared, consists of representatives from the following Government departments and scientific and industrial organizations: Aluminium Federation In
4、stitution of Mining and Metallurgy Association of Bronze and Brass Founders Institution of Production Engineers Association of Consulting Engineers Institution of Structural Engineers Board of Trade Lead Development Association British Bronze and Brass Ingot Manufacturers Light Metal Founders Associ
5、ation Association London Metal Exchange British Electrical and Allied Manufacturers Magnesium Industry Council* Association Ministry of Defence, Army Department* British Lead Manufacturers Association Ministry of Defence, Navy Department British Non-ferrous Metals Federation National Brassfoundry As
6、sociation British Non-ferrous Metals Research Non-ferrous Metal Stockists* Association* Post Office Copper Development Association Royal Institute of British Architects Crown Agents for Overseas Governments and Society of British Aerospace Companies Ltd. Administrations Society of Motor Manufacturer
7、s and Electric Cable Makers Confederation TradersLtd.* High Conductivity Copper Association Tin Research Institute Institute of British Foundrymen Zinc Development Association Institute of Metals Individual manufacturer Institution of Mechanical Engineers (Automobile Division) The Government departm
8、ent and scientific and industrial organizations marked with an asterisk in the above list, together with the following, were directly represented on the committee entrusted with the preparation of this Britishstandard: Institute of Sheet Metal Engineering Individual analysts Ministry of Aviation Min
9、istry of Technology, Laboratory of the Government Chemist Amendments issued since publication Amd. No. Date CommentsBS3907-5:1966 BSI 12-1999 i Contents Page Co-operating organizations Inside front cover Foreword ii Introduction 1 Apparatus 1 Solutions required 1 Sampling 1 Procedure 1 Calibration 2
10、 Calculation 2BS3907-5:1966 ii BSI 12-1999 Foreword This standard makes reference to the following BritishStandard: BS1499, Sampling non-ferrous metals. This method for the photometric determination of manganese (low contents) in magnesium and magnesium alloys is the fifth of a series which will for
11、m a complete BritishStandard under the collective title “Methods for the analysis of magnesium and magnesium alloys” each being published as a separate part. Other methods in the series are as follows: Part1: Aluminium in magnesium alloys (gravimetric method); Part2: Iron in magnesium and magnesium
12、alloys (photometric 1 : 10-phenanthroline method); Part3: Copper in magnesium and magnesium alloys (photometric method); Part4: Manganese in magnesium and magnesium alloys (photometric periodate method). The preparation of this series of methods has been authorized by the Non-ferrous Metals Industry
13、 Standards Committee as part of a general programme for the standardization of methods for the sampling and analysis of non-ferrous metals. The methods have been found to give reliable and reproducible results and, while in some instances they may appear to be lengthy, it should be appreciated that
14、they are primarily intended as “referee” methods to be used in cases of dispute. This method is substantially the same as the corresponding method approved by ISO/TC79 which will be published as ISO R. . . . . . 1) . A British Standard does not purport to include all the necessary provisions of a co
15、ntract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 and 2, an inside back co
16、ver and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. 1) In course of preparation.BS3907-5:1966 BSI 12-1999 1 Introduction a) Principle. The sample is dissolved in s
17、ulphuric acid and oxidized with ammonium persulphate. The manganous ions are oxidized to permanganic acid with potassium periodate in the presence of phosphoric acid. The optical density is measured at about525nm. b) Range. The method is suitable for manganese contents less than0.01per cent. c) Repr
18、oducibility. Experiments have been carried out independently by a number of analysts using this method. The degree of reproducibility that can be expected is shown by the following analysis of the results obtained: d) Application. The method is not suitable for alloys containing zirconium, rare eart
19、hs or thorium. Apparatus a) Class A volumetric glassware complying with the appropriate BritishStandards shall be used throughout. b) Any instrument suitable for measuring the optical density of the solution at a wave-length of525nm may be used with4cm cells. Alternatively when a filter photometer o
20、f the balanced two-cell type is used the following conditions have been found suitable: Mercury vapour lamp. Ilford604 with H503 or equivalent filters. 4cm cells. Solutions required All reagents shall be of the highest purity obtainable and either distilled or demineralized water shall be used throu
21、ghout. Solutions shall be freshly prepared and where necessary filtered. Standard manganese (1mlN 1mg of manganese). Dissolve2.877g of very pure potassium permanganate in about200ml of water and add40ml of sulphuric acid(25per cent). Reduce by adding a few crystals of sodium sulphite or by adding hy
22、drogen peroxide(100vol). Boil to eliminate excess SO 2or H 2 O 2 , cool, transfer to a1litre volumetric flask, dilute to the mark and mix. Alternatively: Weigh1.000g of high purity manganese(99.9per cent min. purity), transfer to a600ml tall form beaker, add80ml of water and40ml of sulphuric acid(25
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS390751966METHODSFORTHEANALYSISOFMAGNESIUMANDMAGNESIUMALLOYSDETERMINATIONOFMANGANESEINMAGNESIUMANDMAGNESIUMALLOYSPHOTOMETRICPERIODATEMETHODLOWCONTENTPDF

链接地址:http://www.mydoc123.com/p-543981.html