ASTM F2257-2009 Standard Specification for Wrought Seamless or Welded and Drawn 18 Chromium-14Nickel-2 5Molybdenum Stainless Steel Small Diameter Tubing for Surgical Implants (UNS .pdf
《ASTM F2257-2009 Standard Specification for Wrought Seamless or Welded and Drawn 18 Chromium-14Nickel-2 5Molybdenum Stainless Steel Small Diameter Tubing for Surgical Implants (UNS .pdf》由会员分享,可在线阅读,更多相关《ASTM F2257-2009 Standard Specification for Wrought Seamless or Welded and Drawn 18 Chromium-14Nickel-2 5Molybdenum Stainless Steel Small Diameter Tubing for Surgical Implants (UNS .pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2257 09Standard Specification forWrought Seamless or Welded and Drawn 18 Chromium-14Nickel-2.5Molybdenum Stainless Steel Small DiameterTubing for Surgical Implants (UNS S31673)1This standard is issued under the fixed designation F 2257; the number immediately following the designation
2、 indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers the requir
3、ements for wrought18chromium-14nickel-2.5molybdenum stainless steel tubingused for the manufacture of surgical implants. Material shallconform to the applicable requirements of Specification F 138(for seamless) or Specification F 139 (for welded and drawn).This specification addresses those product
4、variables that dif-ferentiate small-diameter medical grade tubing from the bar,wire, sheet, and strip product forms covered in these specifi-cations.1.2 This specification applies to cold finished straight lengthtubing with 3 mm (0.125 in.) and smaller nominal outsidediameter (OD) and 0.5 mm (0.020
5、in.) and thinner nominalwall thickness.1.3 The specifications in 2.1 are referred to as the ASTMmaterial standard(s) in this specification.1.4 The values stated in either inch-pound or SI units are tobe regarded separately as standard. Inch-pound units are shownin parentheses. The values stated in e
6、ach system may not beexact equivalents; therefore, each system shall be used inde-pendently of the other. Combining values from the two systemsmay result in non-conformance with the standard.2. Referenced Documents2.1 ASTM Material Standards:2F 138 Specification for Wrought 18Chromium-14Nickel-2.5Mo
7、lybdenum Stainless Steel Bar and Wire for SurgicalImplants (UNS S31673)F 139 Specification for Wrought 18Chromium-14Nickel-2.5Molybdenum Stainless Steel Sheet and Strip for Surgi-cal Implants (UNS S31673)2.2 ASTM Standards:2A 632 Specification for Seamless and Welded AusteniticStainless Steel Tubing
8、 (Small-Diameter) for General Ser-viceE 8/E 8M Test Methods for Tension Testing of MetallicMaterialsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE112 Test Methods for Determining Average Grain SizeF 2181 Specification for Wrought Seamless Stainles
9、s SteelTubing for Surgical ImplantsSI 10 American National Standard for Use of the Interna-tional System of Units (SI): The Modern Metric System2.3 ISO Standards:3ISO 5832-1 Implants for SurgeryMetallic Materials Part1: Wrought Stainless SteelISO 6892 Metallic MaterialsTensile TestingISO 9001 Qualit
10、y Management SystemsRequirements2.4 ASME Standards:4ASME Y14.5.1M Mathematical Definition of Dimension-ing and Tolerancing Principles3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 individual wall thickness measurementany one ofthe wall thickness measurements taken around the
11、circumfer-ence on any one transverse cross section of a single sample ofthe tube.3.1.2 lotthe total number of mill products produced fromthe same melt heat under the same conditions at essentially thesame time.3.1.3 lot average concentricitythe arithmetic average ofthe sample concentricities measure
12、d on a statistically represen-tative number of samples from the lot.3.1.4 lot average wall thicknessthe arithmetic average ofthe sample average wall thicknesses measured on a statisticallyrepresentative number of samples from the lot.3.1.5 nominal wall thicknessthe wall thickness specifiedby the pur
13、chaser without regard to tolerance.1This specification is under the jurisdiction of ASTM Committee F04 onMedical and Surgical Materials and Devices and is the direct responsibility ofSubcommittee F04.12 on Metallurgical Materials.Current edition approved Feb. 1, 2009. Published July 2009. Originally
14、 approvedin 2003. Last previous edition approved in 2003 as F 2257 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM
15、 website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4Available from American Society of Mechanical Engineers (ASME), ASMEInternational Headquarters, Three Park Ave., New York, NY 10016-5990, http:/www.asme.org.1*A Su
16、mmary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.6 sample average wall thicknessthe arithmetic aver-age of all individual wall thickness measurements measured ona single
17、sample.3.1.7 sample concentricitytwo times the offset betweenthe centers of the two circles representing the outside diameter(OD) and the inside diameter (ID) of the tube.3.1.7.1 DiscussionFor the purposes of this specification,the sample minimum wall and the sample maximum wallmeasured on any one t
18、ransverse cross section of a singlesample shall be used to calculate sample concentricity. Thesample maximum, and sample minimum wall thickness shallbe the largest and smallest respectively of no less than fourindividual wall thickness measurements taken at uniformlyspaced locations around the circu
19、mference of a single sampleof the tube. Sample concentricity shall be expressed as apercent of the wall thickness and shall be calculated using thefollowing equation:sample concentricity percent 5 2 3SA 2 BA 1 BD3 100where:A = sample maximum wall, andB = sample minimum wall.3.1.8 sample maximum wall
20、 thicknessthe largest indi-vidual wall thickness measurement taken around the circum-ference on any one transverse cross section of a single sampleof tube.3.1.9 sample minimum wall thicknessthe smallest indi-vidual wall thickness measurement taken around the circum-ference on any one transverse cros
21、s section of a single sampleof tube.3.1.10 seamless tubingtubing made by a process in whichthe tube periphery is continuous at all stages of the process.3.1.11 welded and drawn tubingtubing fabricated fromstrip or sheet using welding, drawing, and annealing opera-tions.4. General Requirements for De
22、livery4.1 In addition to the requirements of this specification, allapplicable requirements of the appropriate ASTM materialstandard shall apply.4.2 In addition to the requirements of this specification, allapplicable requirements of Specification A 632 shall apply.4.3 If a conflict exists between t
23、his specification and thoselisted in Section 2, or if a conflict exists between thosespecifications listed in 2.1 and those listed in 2.2 and 2.3, thefollowing order of precedence applies: (1) this specification,(2) the ASTM material standard referenced on the purchaseorder, and (3) all other refere
24、nced specifications.5. Ordering Information5.1 Inquiries and orders for material under this specificationshould include the following information:5.1.1 Quantity (weight, total length or number of pieces),5.1.2 This ASTM specification and date of issue,5.1.3 The appropriate ASTM material standard (Sp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF22572009STANDARDSPECIFICATIONFORWROUGHTSEAMLESSORWELDEDANDDRAWN18CHROMIUM14NICKEL25MOLYBDENUMSTAINLESSSTEELSMALLDIAMETERTUBINGFORSURGICALIMPLANTSUNSPDF

链接地址:http://www.mydoc123.com/p-538224.html