ASTM F756-2013 Standard Practice for Assessment of Hemolytic Properties of Materials《评估材料溶血性能的标准实施规程》.pdf
《ASTM F756-2013 Standard Practice for Assessment of Hemolytic Properties of Materials《评估材料溶血性能的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F756-2013 Standard Practice for Assessment of Hemolytic Properties of Materials《评估材料溶血性能的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F756 13Standard Practice forAssessment of Hemolytic Properties of Materials1This standard is issued under the fixed designation F756; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revision.Anumber in
2、 parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice provides a protocol for the assessment ofhemolytic properties of materials used in the fabrication ofmedical devices that will conta
3、ct blood.1.2 This practice is intended to evaluate the acute in vitrohemolytic properties of materials intended for use in contactwith blood.1.3 This practice consists of a protocol for a hemolysis testunder static conditions with either an extract of the material ordirect contact of the material wi
4、th blood. It is recommendedthat both tests (extract and direct contact) be performed unlessthe material application or contact time justifies the exclusionof one of the tests.1.4 This practice is one of several developed for theassessment of the biocompatibility of materials. Practice F748may provid
5、e guidance for the selection of appropriate methodsfor testing materials for a specific application. Test MethodE2524 provides a protocol using reduced test volumes to assessthe hemolytic properties of blood-contacting nanoparticulatematerials; this may include nanoparticles that become unboundfrom
6、material surfaces.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard
7、 to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE2524 Test Method for Analysis of
8、Hemolytic Properties ofNanoparticlesF619 Practice for Extraction of Medical PlasticsF748 Practice for Selecting Generic Biological Test Methodsfor Materials and Devices3. Terminology3.1 Definitions:3.1.1 plasma hemoglobinamount of hemoglobin in theplasma.3.1.2 % hemolysisfree plasma hemoglobin conce
9、ntration(mg/mL) divided by the total hemoglobin concentration (mg/mL) present multiplied by 100. This is synonymous withhemolytic index.3.1.3 comparative hemolysiscomparison of the hemolyticindex produced by a test material with that produced by astandard reference material such as polyethylene unde
10、r thesame test conditions.3.1.4 direct contact testtest for hemolysis performed withthe test material in direct contact with the blood.3.1.5 extract testtest for hemolysis performed with anisotonic extract of the test material, as described in PracticeF619, in contact with the blood.3.1.6 hemolysisd
11、estruction of erythrocytes resulting in theliberation of hemoglobin into the plasma or suspension me-dium.3.1.7 negative controlmaterial, such as polyethylene, thatproduces little or no hemolysis (0.50 mm 60 cm2:20.0mL 21cm2:7.0mL1.0 mmor intricate geom-etry4.0g:20.0mL 1.4g:7.0mL9.2.2 Samples are cu
12、t into appropriate pieces. Transfer eachof three nonextracted samples of test and control specimensinto individual tubes as described in 9.1.3. The recommendedtube size is 16 125 mm. However the tube size may be anysuch that the specimen is covered by 7.0 mL of PBS liquid.Place 7.0 mL of PBS into ea
13、ch tube containing the nonex-tracted sample. Place 7.0 mLof PBS into each of three tubes toserve as the blank.9.3 TestAdd 1.0 mL of blood prepared according to 8.4.4to each tube containing extract, each tube containing aspecimen, and the blanks. Cap all tubes.NOTE 4This procedure calls for preparing
14、 the sample, adding thediluent to the sample and then adding the blood, which minimizes the timedifference for contact of the sample with blood. Alternatively, the bloodmay be added to the diluent and then the sample added to the preparedsolution. Whichever method is chosen must be used for the cont
15、rols aswell as the test specimens.9.4 Maintain tubes in a suitable test tube rack for at least 3hat376 2C in a water bath. Gently invert each tube twiceapproximately every 30 min to maintain contact of the bloodand material. In some cases of samples with complicatedconfigurations, it may be necessar
16、y to do more inversions toadequately mix the sample.9.5 At the end of the specified incubation time, transfer thefluid to a suitable tube and centrifuge at 700 to 800 G for 15min in a standard clinical centrifuge.9.6 Remove the supernatant carefully to avoid disturbingany button of erythrocytes whic
17、h may be present. Place thesupernatant into a second screw cap tube. Record the presenceof any color to the supernatant and any precipitate.9.7 Analyze the samples from 9.6 for supernatant hemoglo-bin concentration using the method in 9.8.9.8 Supernatant Hemoglobin Determination:9.8.1 Add 1.0 mL of
18、supernatant to 1.0 mL of cyanmethe-moglobin reagent, or validated diluent.9.8.2 Allow the sample to stand for 15 min for Drabkins or3 to 5 min for cyanmethemoglobin reagent. Read the absor-bance of the solution with a spectrophotometer at a wavelengthof 540 nm.9.8.3 In the unlikely event that A540ex
19、ceeds 2, this maysignify a procedural or background problem; the problemshould be identified and addressed, and the testing repeated.9.8.3.1 Determine the hemoglobin concentration in eachsupernatant from 9.8 using the calibration curve.9.8.3.2 The hemoglobin concentration of supernatant fromthe test
20、 sample or control tubes is calculated as follows (usingthe absorbance value obtained in 9.8.2 and correcting for thedilution factor of 2): :S 5 AS3 F 32 (4)The hemoglobin concentration of the blank tube is calcu-lated as follows:B 5 AB3 F 32 (5)9.8.3.3 Calculate the % hemolysis or hemolytic index a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF7562013STANDARDPRACTICEFORASSESSMENTOFHEMOLYTICPROPERTIESOFMATERIALS 评估 材料 溶血 性能 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-537225.html