ASTM F1460-2007 Standard Practice for Calibrating Oil Spill Dispersant Application Equipment Boom and Nozzle Systems《校准溢油分散剂应用设备输油管和喷油嘴系统的标准实施规程》.pdf
《ASTM F1460-2007 Standard Practice for Calibrating Oil Spill Dispersant Application Equipment Boom and Nozzle Systems《校准溢油分散剂应用设备输油管和喷油嘴系统的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1460-2007 Standard Practice for Calibrating Oil Spill Dispersant Application Equipment Boom and Nozzle Systems《校准溢油分散剂应用设备输油管和喷油嘴系统的标准实施规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1460 07Standard Practice forCalibrating Oil Spill Dispersant Application EquipmentBoom and Nozzle Systems1This standard is issued under the fixed designation F 1460; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers uniform procedures for determiningand reporting the dosage rate of oil spill dispersan
3、t applicationequipment.1.2 This practice is applicable to spray systems employingbooms and nozzles and is not fully applicable to other systemssuch as fire monitors, sonic distributors, or fan-spray guns.1.3 This practice is applicable to systems for use on ships orboats and helicopters or airplanes
4、.1.4 This practice is one of four related to dispersant appli-cation systems using booms and nozzles. One is on design, oneon calibration, one on deposition, and one on the use of thesystems. Familiarity with all four standards is recommended.1.5 This standard does not purport to address all of thes
5、afety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F 1413 Guide for Oil Spill Di
6、spersant Application Equip-ment: Boom and Nozzle Systems3. Significance and Use3.1 This practice will enable calibration of oil spill dispers-ant application equipment and ensure a desired dosage anduniformity across the swath width.3.2 The data provided by the methods described herein willpermit th
7、e preparation of a chart relating delivery rate withapplication vehicle speed, flow meter reading or pump settingso that in actual application, the desired dosage will beachieved.3.3 This practice will ensure that a dispersant applicationsystem is functional, capable of delivering a specified dosage
8、,and that major components are operational. This will alsoensure that the unit is functioning according to design specifi-cations as detailed in Guide F 1413.4. Apparatus and Materials4.1 Pails of capacity 7 to 20 L (2 to 5 U.S. gal) to catchthe spray from the nozzles.4.2 Graduated Cylinder of capac
9、ity 7 to 20 L or a scalehaving capacity of at least 20 kg (45 lbs) to determine theamount of fluid in each pail. Commercial equipment with anaccuracy of at least 1 % is adequate.4.3 Stopwatch.4.4 Test FluidWater can be used as a test fluid if theviscosity of the dispersant to be used is not dissimil
10、ar to theviscosity of water. A surrogate fluid should be used if theviscosity difference is greater than approximately 100 timesthat of water. This can occur with more viscous dispersants orat low temperatures. The surrogate fluid could be water withthe appropriate amount of thickener.4.5 A continui
11、ng supply of water or test fluid, enough to runthe system during the test period, must be available. Tank truckquantities may be required.4.6 Auxiliary Power Units, where required.4.7 Thermometer, to measure the temperature of test fluid.4.8 FlowmeterA flowmeter should be incorporated intothe delive
12、ry system to measure the total flow out to the boomsand nozzles.5. Calibration Procedure5.1 SynopsisThe calibration procedure is done in foursteps. The first step is equipment inspection. Any defects arecorrected before further calibration. The second step is thecalibration of the flow meter. The th
13、ird step is calibration of theunit by catching water spray from each nozzle. The fourth stepis the preparation of a calibration curve.1This practice is under the jurisdiction of ASTM Committee F20 on HazardousSubstances and Oil Spill Response and is the direct responsibility of SubcommitteeF20.13 on
14、 Treatment.Current edition approved April 1, 2007. Published April 2007. Originallyapproved in 1993. Last previous edition approved in 1999 as F 1460 93 (1999).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of
15、 ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 Equipment Setup Place the application equipment at asuitable outdoor location and
16、close to a supply of water or testfluid. Set up the equipment in accordance with the manufac-turers instructions and inspect visually. Start the unit. Allnozzles should visually be producing approximately the sameamount of spray. Inoperative nozzles or other elements such aspressure gages or flow me
17、ters, are repaired or replaced beforeproceeding. The operation of pressure gages should be verifiedbefore proceeding.5.3 Dispersant Flow Meter Calibration:5.3.1 Calibrate the flow meter using a surrogate fluid. Thissurrogate fluid could be water or a surrogate fluid, if necessary.The withdrawal of t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF14602007STANDARDPRACTICEFORCALIBRATINGOILSPILLDISPERSANTAPPLICATIONEQUIPMENTBOOMANDNOZZLESYSTEMS

链接地址:http://www.mydoc123.com/p-534932.html