ASTM E937-1993(2011) 0000 Standard Test Method for Corrosion of Steel by Sprayed Fire-Resistive Material (SFRM) Applied to Structural Members《结构构件上喷涂防火材料(SFRM)对钢腐蚀性的标准试验方法》.pdf
《ASTM E937-1993(2011) 0000 Standard Test Method for Corrosion of Steel by Sprayed Fire-Resistive Material (SFRM) Applied to Structural Members《结构构件上喷涂防火材料(SFRM)对钢腐蚀性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E937-1993(2011) 0000 Standard Test Method for Corrosion of Steel by Sprayed Fire-Resistive Material (SFRM) Applied to Structural Members《结构构件上喷涂防火材料(SFRM)对钢腐蚀性的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E937 93 (Reapproved 2011)Standard Test Method forCorrosion of Steel by Sprayed Fire-Resistive Material(SFRM) Applied to Structural Members1This standard is issued under the fixed designation E937; the number immediately following the designation indicates the year oforiginal adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a procedure for measuring thecorrosion to steel induced
3、 by sprayed fire-resistive material.1.2 These SFRMs include sprayed fibrous and cementitiousmaterials applied directly in contact with the structural mem-bers.1.3 This test method is applicable only to laboratory proce-dures.1.4 The values stated in SI units are to be regarded as thestandard. The va
4、lues given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this stan
5、dard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E119 Test Methods for Fire Tests of Building Constructionand MaterialsE605 Test Methods for Thickness and Density of SprayedFi
6、re-Resistive Material (SFRM) Applied to StructuralMembersE631 Terminology of Building Constructions3. Terminology3.1 DefinitionsDefinitions in this test method are in ac-cordance with Terminology E631.3.2 Definitions of Terms Specific to This Standard:3.2.1 corrosionchemical reaction between a metal
7、 and itsenvironment that produces a deterioration of the metal and itsproperties.3.2.2 sprayed fire-resistive materialsmaterials that aresprayed onto substrates to provide fire-resistive protection ofthe substrates.4. Summary of Test Method4.1 In this test method replicate panels of bare, shop-coate
8、d,and galvanized steel are sprayed with SFRM and subjected toroom temperature and humidity conditions and to 240 h ofconditioning in a temperature- and humidity-controlled cham-ber. Corrosion induced under these conditions is determined byweight loss3of the sheets as related to sheets not so condi-t
9、ioned.5. Significance and Use5.1 It is the intent of this test method to determine relativecorrosive properties of direct applied SFRM that provides anindication of serviceability. Satisfactory performance of SFRMapplied to structural members and assemblies depends upon itsability to withstand the v
10、arious influences that occur during thelife of the structure, as well as upon its satisfactory perfor-mance under fire conditions.5.2 This test method evaluates the relative corrosion of steelinduced by SFRM and determines whether the presence ofSFRM increases, decreases, or has no effect on the cor
11、rosioncharacteristics of steel.6. Apparatus6.1 Standard Temperature Humidity Cabinet, equipped tomaintain the temperature at 35 6 1.7C (95 6 3F) and arelative humidity of 95 6 3 %. The cabinet and all accessoriesshall be of a material that does not affect the corrosiveness ofthe atmosphere in the ca
12、binet. Additionally, all parts that comeinto contact with the test specimens shall be made of materialthat will not cause electrolytic corrosion. Adequate circulationof the atmosphere over the specimens shall be provided.1This test method is under the jurisdiction of ASTM Committee E06 onPerformance
13、 of Buildings and is the direct responsibility of Subcommittee E06.21on Serviceability.Current edition approved April 1, 2011. Published May 2011. Originallyapproved in 1983. Last previous edition approved in 2005 as E937 93 (2005).DOI: 10.1520/E0937-93R11.2For referenced ASTM standards, visit the A
14、STM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Although “mass” is being determined, the term weight is used in this testmethod as an accepted substitu
15、te.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.2 Scale, having a capacity of 5 kg and a sensitivity of60.1 g.6.3 Wire Brush, described as “cement mold brush” withbrass wire bristles 25 mm (1 in.) long mounted in a handle. Thebr
16、istle section shall be 127 mm (5 in.) long by 19 mm (34 in.)wide.7. Materials7.1 This test method requires the application of SFRM inaccordance with manufacturers published instructions. Theapparatus, materials, and procedures used to apply the SFRMshall be representative of application in the field
17、.7.2 The density of the prepared sample shall be the same asthe density tested and reported during the Test Methods E119fire exposures or as required by the sponsor of the test.7.3 Determine the density and thickness of each laboratory-prepared specimen. Report in accordance with Test MethodsE605.7.
18、4 Steel sheets shall be 200 mm by 200 mm (8 in. by 8 in.)by minimum 12 gage and shall be: bare steelA36 grade,galvanized steelG60 grade, and shop-coatedA36 gradesteel coated with iron oxide alkyd shop coat primer.8. Laboratory Test Specimens8.1 The three sets of specimens shall consist of four sheet
19、seach, in the following categories: bare, shop-coated, andgalvanized steel.8.2 The steel sheets shall be free of all surface rust. Washthe metal specimens with analytical grade trichlorethylene toremove any oil or grease. Dry at room temperature. For testpurposes of this test method, the duplicate s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME937199320110000STANDARDTESTMETHODFORCORROSIONOFSTEELBYSPRAYEDFIRERESISTIVEMATERIALSFRMAPPLIEDTOSTRUCTURALMEMBERS

链接地址:http://www.mydoc123.com/p-533808.html