1、Designation: E787 81 (Reapproved 2011)Standard Specification forDisposable Glass Micro Blood Collection Pipets1This standard is issued under the fixed designation E787; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers two dimension
3、ally differentdisposable glass micropipets used primarily to collect wholehuman blood specimens for clinical analysis and testing. Theyare available as coated with heparin or uncoated.2. Referenced Documents2.1 ASTM Standards:2E438 Specification for Glasses in Laboratory Apparatus3. Terminology3.1 D
4、efinitions of Terms Specific to This Standard:3.1.1 disposable micropipetsin accordance with thisspecification and the expected product performance expressedin this standard, those pipets which are to be used one timeonly. Any institution or individual who reuses a disposablepipet must bear full res
5、ponsibility for its safety and effective-ness.4. Classification4.1 This specification covers two dimensionally differentdisposable glass pipets as follows:4.1.1 Short PipetApproximately 75 mm long and coatedwith heparin (Type I) or uncoated (Type II). These arecommercially recognized as Caraway pipe
6、ts.34.1.2 Long PipetApproximately 150 mm long and coatedwith heparin (Type I) or uncoated (Type II). These arecommercially recognized as Natelson pipets.45. Materials and Manufacture5.1 GlassThe pipets shall be fabricated from borosilicateglass, Type I, Class B, or soda lime glass, Type II, inaccord
7、ance with Specification E438.5.2 Heparinshall be the ammonium salt isolated from thelungs or intestinal mucosa of beef or pork origin. The heparinpotency shall be 1 mg of ammonium heparin compound whichis equal to at least 100 USP units.56. Physical Requirements6.1 DesignThe disposable glass micro b
8、lood collectionpipets, both short and long, shall be straight and pulled to atapered point at one end. Any cross section of the pipets, takenin a plane perpendicular to the longitudinal axis, shall becircular. The pipets shall be lightly firepolished at both endswith no run-in and possess color band
9、s to denote presence orabsence of heparin content.6.2 Dimensions:6.2.1 The short Caraway pipet shall be approximately 75mm long and 4 mm in outside diameter. The pipet shall hold aliquid volume of 310 to 470 L. The tapered point length andtip orifice opening shall be as specified in Fig. 1.6.2.2 The
10、 long Natelson pipet shall be approximately 150mm long and 3 mm in outside diameter. The pipet shall hold aliquid volume of 220 to 420 L. The tapered point length andtip orifice opening shall be as specified in Fig. 2.6.3 WorkmanshipThe pipets, as illustrated in Fig. 1 andFig. 2, shall be free of de
11、fects that noticeably detract from theirappearance or impair their serviceability. They shall be free oflint, or significant foreign matter, loose or embedded whenviewed under normal room lighting. The top and tip ends of thepipets shall be cut at approximately 90 to the pipet axis andshall not be c
12、racked or have jagged ends or chips that enter thebore of the pipet.6.4 Color CodingEach disposable glass micro blood col-lection pipet shall be color-coded to identify the pipet. Theheparin-coated pipet (Type 1) shall have a red color band. The1This specification is under the jurisdiction of ASTM C
13、ommittee E41 onLaboratory Apparatus and is the direct responsibility of Subcommittee E41.01 onApparatus.Current edition approved Dec. 1, 2011. Published December 2011. Originallyapproved in 1981. Last previous edition approved in 2006 as E787 81 (2006)1.DOI: 10.1520/E0787-81R11.2For referenced ASTM
14、standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Caraway, W. T., and Fanger, H., “Ultramicro Procedures In Clinical Chemis-try,” A
15、merican Journal of Clinical Pathology , 25, 1955, pp. 316331.4Natelson, S., Ph.D., Micro-Techniques of Clinical Chemistry, Charles C.Thomas, Springfield, Ill., 1961, p. 70.5The United States Pharmacopeia, 19th Revision, pp. 229230.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, We
16、st Conshohocken, PA 19428-2959, United States.uncoated pipet (Type 2) shall have a blue color band. Thelocation of these color bands shall be as specified in Fig. 1 andFig. 2.6.5 CapillaryThe pipets, both short and long, shall becapable of drawing sheep plasma or human whole blood thefull length of
17、the pipet when tested as specified in 7.1.6.6 Fluidity (Type 1, Heparinized, only)Coagulation ofthe sheep plasma or human whole blood shall not be evidentwhen viewed under normal room lighting and tested asspecified in 7.2.6.7 Lot or Control NumberA lot or control number shallbe indicated on the int
18、ermediate and outer package of pipets.This lot or control number shall be traceable to the origin (rawmaterial glass and heparin purchases) of the manufacturingrecord.6.8 Resistance to Centrifugal Forces The pipets, bothshort and long, may be subject to centrifugal force undernormal analysis or test
19、 procedures. No breakage shall resultwhen tested as specified in 7.3.6.9 Heparin Coating (Type 1, Heparinized, only)Theinner surface of the short and long pipets shall be evenly coatedwith ammonium heparin. A minimum of 5.0 units of heparinactivity shall be present in the tube when tested as specifi
20、ed in6.4. A statement on expected units of heparin and an expirationdate may be claimed by the manufacturer. This option may beexpressed on the pipet package label.7. Test Methods7.1 Capillarity TestTest the pipets, both short and long,for capillarity when held at a near horizontal level. The pipets
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME787198120116250STANDARDSPECIFICATIONFORDISPOSABLEGLASSMICROBLOODCOLLECTIONPIPETS 一次性 微型 血液 收集 玻璃

链接地址:http://www.mydoc123.com/p-533522.html