ASTM F19-1964(2005)e1 Standard Test Method for Tension and Vacuum Testing Metallized Ceramic Seals《镀金属陶瓷密封件抗拉及真空试验方法》.pdf
《ASTM F19-1964(2005)e1 Standard Test Method for Tension and Vacuum Testing Metallized Ceramic Seals《镀金属陶瓷密封件抗拉及真空试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F19-1964(2005)e1 Standard Test Method for Tension and Vacuum Testing Metallized Ceramic Seals《镀金属陶瓷密封件抗拉及真空试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 19 64 (Reapproved 2005)e1Standard Test Method forTension and Vacuum Testing Metallized Ceramic Seals1This standard is issued under the fixed designation F 19; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year
2、of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEIn 6.1, cm was editorially changed to cc in January 2005.1. Scope1.1 This test method covers procedures for conductingtensio
3、n and vacuum tests on metal-ceramic seals to determinethe bond strength of brazed, metallized ceramics. This testmethod is not to be considered as an absolute tension test forthe ceramic.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are
4、forinformation only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to
5、 use.2. Referenced Documents2.1 ASTM Standards:E4 Practices for Force Verification of Testing Machines2E6 Terminology Relating to Methods of Mechanical Test-ing23. Terminology3.1 Definitions:3.1.1 The definitions of terms relating to tension testingappearing in Definitions E6, shall apply to the ter
6、ms used inthis test method.4. Apparatus4.1 Testing MachinesMachines used for tension testingshall conform to the requirements of Methods E4. Only loadsthat are within the loading range of the testing machine, asdefined in Methods E4, shall be used for determining tensilestrengths.4.2 Gripping Device
7、sVarious types of gripping devicesmay be used to apply the load to the test specimen. Thoseshown in Fig. 1 are recommended, but regardless of whichgrips are used, care shall be taken that the axis of the testspecimen is in alignment with the centerline of the test machineheads.5. Preparation of Spec
8、imens5.1 Prepare the test specimen by brazing together two piecesof ceramic, shown in Fig. 2, at their respective metalizedsurfaces, as described in 5.1.1 to 5.1.3:5.1.1 CeramicsGrind the test surface, A,(Fig. 2)ofthetwo ceramic parts flat to within 0.00025 in. (0.0064 mm)according to good grinding
9、practice using an abrasive passingor finer than a No. 100 (150-m) sieve. The ground surface, A,of each part shall be parallel to shoulder C, as shown in Fig. 2,consistent with the best commercial practice. The over-allappearance of each ceramic half of the test specimen shallindicate good commercial
10、 practice, and shall be free fromobvious defects. In the results of the test, report the method ofmanufacture of the specimen components, that is, slip cast,hotpressed, hydrostatically molded, etc. Measure and recordthe test surface area of each ceramic half on a projectioncomparator, or by other su
11、itable means. Dye check the twoceramic parts and inspect them for flaws (Note 1). Reject allparts showing flaws considered conducive to abnormal failuresof either ceramic part.NOTE 1A suggested dye check procedure is described in the Appen-dix.5.1.2 Metallized CoatingMetallize the specimen halvesund
12、er identical conditions, that is, temperature, atmosphere,etc. The type of metallizing used is optional, or as mutuallyagreed upon between producer and consumer. Apply themetallizing coating only to the test surface A, Fig. 2, on thespecimen. The method of metallizing is optional, that is, silkscree
13、n, brush, spray, roller, etc., but should be reported.NOTE 2A typical metallizing procedure is described in the Appendix.5.1.3 Assembling the Test SpecimenPlace the two matingparts in a suitable jig to achieve axial alignment of the matedceramic halves and alignment of the metallized surfaces.Accura
14、te alignment, which is essential to attain uniform test1This test method is under the jurisdiction of ASTM Committee F01 onElectronics and is the direct responsibility of Subcommittee F01.03 on MetallicMaterials.Current edition approved Jan. 1, 2005. Published January 2005. Originallyapproved in 196
15、1 as F 19 61 T. Last previous edition approved in 2000 as F 19 64(2000).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe AS
16、TM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.results, may be accomplished by jigging with a rod ofrefractory material, such as ceramic or carbon (Fig. 3). Pass therod through the assembly and then braze the specimen in
17、avertical position. In the test results, report the brazing materialused; such as copper-silver eutectic, copper-gold alloy, 35 to65 %, etc. Use sufficient material to produce an even fillet atNOTE 1Tolerance on all dimensions shown, 60.016 in. (0.41 mm).FIG. 1 Self Aligning Grip for Tension TestASe
18、al surface area to be metalized.BSurface inscribed with date as to ceramic batch and firing temperature.CGripping shoulder.FIG. 2 Ceramic Half of Tension Test SpecimenF 19 64 (2005)e12the joint. Load the assembly to produce pressure on the sealduring the brazing operation and report the weight of th
19、e load.6. Procedure6.1 Leak TestThe brazed test specimen may be vacuum-leak checked on any conventional helium spectrometer-typeleak checker with a sensitivity of 5 3 109cc/s at standardtemperature and pressure. Subject the specimen continuouslyto an atmosphere of helium for12 to 5 min. The leak-che
20、ckinginstrument, set at maximum sensitivity, shall show no indica-tion of a leak during the test period.6.2 Tension Test Place the specimen in the self-aligninggrips with a polytetrafluoroethylene (TFE-fluorocarbon)washer between the ceramic and the jaws of the grip (see Fig.1). Test all specimens u
21、nder the same loading rate which,although optional, shall be reported.6.3 Other Tests Brazed assemblies prepared in accor-dance with Section 5 can also be used to:6.3.1 Test ceramic-metal seals with a metal washer insertedbetween the test pieces, and6.3.2 Perform environmental tests such as heat sho
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF1919642005E1STANDARDTESTMETHODFORTENSIONANDVACUUMTESTINGMETALLIZEDCERAMICSEALS 镀金 陶瓷 密封件 真空 试验 方法

链接地址:http://www.mydoc123.com/p-532494.html