《ASTM E2663-2008 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Ultrasonic Test Methods《非破坏性评估中数字成像和传播的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2663-2008 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Ultrasonic Test Methods《非破坏性评估中数字成像和传播的标准实施规程》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2663 08Standard Practice forDigital Imaging and Communication in NondestructiveEvaluation (DICONDE) for Ultrasonic Test Methods1This standard is issued under the fixed designation E 2663; the number immediately following the designation indicates the year oforiginal adoption or, in th
2、e case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice facilitates the interoperability of ultrasonicimaging equipment by speci
3、fying image data transfer andarchival storage methods in commonly accepted terms. Thisdocument is intended to be used in conjunction with PracticeE 2339 on Digital Imaging and Communication in Nondestruc-tive Evaluation (DICONDE). Practice E 2339 defines an in-dustrial adaptation of the NEMA Standar
4、ds Publication titledDigital Imaging and Communications in Medicine (DICOM,see http:/medical.nema.org), an international standard forimage data acquisition, review, transfer and archival storage.The goal of Practice E 2339, commonly referred to as DI-CONDE, is to provide a standard that facilitates
5、the display andanalysis of NDE test results on any system conforming to theDICONDE standard. Toward that end, Practice E 2339 pro-vides a data dictionary and set of information modules that areapplicable to all NDE modalities. This practice supplementsPractice E 2339 by providing information object
6、definitions,information modules and data dictionary that are specific toultrasonic test methods.1.2 This practice has been developed to overcome the issuesthat arise when analyzing or archiving data from ultrasonic testequipment using proprietary data transfer and storage methods.As digital technolo
7、gies evolve, data must remain decipherablethrough the use of open, industry-wide methods for datatransfer and archival storage. This practice defines a methodwhere all the ultrasonic technique parameters and test resultsare communicated and stored in a standard format regardless ofchanges in digital
8、 technology.1.3 This practice does not specify:1.3.1 A testing or validation procedure to assess an imple-mentations conformance to the standard.1.3.2 The implementation details of any features of thestandard on a device claiming conformance.1.3.3 The overall set of features and functions to be ex-p
9、ected from a system implemented by integrating a group ofdevices each claiming DICONDE conformance.1.4 Although this practice contains no values that requireunits, it does describe methods to store and communicate datathat do require units to be properly interpreted. The SI unitsrequired by this pra
10、ctice are to be regarded as standard. Noother units of measurement are included in this standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health
11、practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 1316 Terminology for Nondestructive ExaminationsE 1454 Guide for Data Fields for Computerized Transfer ofDigital Ultrasonic Testing DataE 2339 Practice for Digital Imaging a
12、nd Communication inNondestructive Evaluation (DICONDE)2.2 Other Documentation:National Electrical Manufacturers Association Standard forDigital Imaging and Communications in Medicine (DI-COM), 200833. Terminology3.1 Definitions:3.1.1 Nondestructive evaluation terms used in this practicecan be found
13、in Terminology E 1316.3.1.2 DICONDE terms used in this practice are defined inPractice E 2339.4. Summary of Practice4.1 A fundamental principle of DICONDE is the use ofstandard definitions and formats for data communication andstorage. This means all systems that are DICONDE compliantuse a common da
14、ta dictionary and common communicationprotocols. To further standardization, the elements in the data1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.11 on DigitalImaging and Communication in Nondestructive
15、 Evaluation (DICONDE).Current edition approved Dec. 15, 2008. Published January 2009.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary
16、page onthe ASTM website.3Available from National Electrical Manufacturers Association (NEMA), 1300N. 17th St., Suite 1752, Rosslyn, VA 22209, http:/www.nema.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.dictionary are organized
17、 into common groups referred to asinformation modules. The data dictionary and informationmodules common to all NDE modalities are defined in PracticeE 2339.4.2 The data dictionary and information modules specifiedin Practice E 2339 do not cover the information storagerequirements for each individua
18、l modality (CT, DR, CR, UT,etc.). Additions to the data dictionary and information modulesare required to support the individual modalities. This practicecontains the additions to the DICONDE data dictionary andinformation modules necessary for ultrasonic inspection.4.3 The highest organizational le
19、vel in the DICONDEinformation model is the information object definition (IOD).An information object definition is a collection of the infor-mation modules necessary to represent a set of test results froma specific modality. This practice contains the informationobject definitions for ultrasonic in
20、spection.5. Significance and Use5.1 Personnel that are responsible for the creation, transfer,and storage of ultrasonic test results will use this standard. Thispractice defines a set of information modules that along withPractice E 2339 and the DICOM standard provide a standardmeans to organize ult
21、rasonic test parameters and results. Theultrasonic test results may be displayed and analyzed on anydevice that conforms to this standard. Personnel wishing toview any ultrasonic inspection data stored in DICONDEformat may use this document to help them decode and displaythe data contained in the DI
22、CONDE compliant inspectionrecord.6. Information Object Definitions6.1 Ultrasound Image IOD Description:6.1.1 The Ultrasound (US) Image Information Object Defi-nition specifies an image that has been created by an ultrasoundimaging device for NDE purposes. The IOD definition willfollow that for US Im
23、ages found in Part 3 Section A.6 of theDICOM standard except as noted in Table 1.6.2 Ultrasound Multi-Frame Image:6.2.1 The Ultrasound Multi-Frame (US-MF) Image Infor-mation Object Definition specifies a multi-frame image that hasbeen created by an ultrasound imaging device for NDEpurposes. The IOD
24、definition will follow that for US-MFImages found in Part 3 Section A.7 of the DICOM standardexcept as noted in Table 2.7. Information Modules7.1 NDE US Image Module:7.1.1 Table 3 specifies the Attributes that describe NDEultrasound images.7.1.1.1 For NDE US Images, Samples per Pixel(0028,0002) is s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME26632008STANDARDPRACTICEFORDIGITALIMAGINGANDCOMMUNICATIONINNONDESTRUCTIVEEVALUATIONDICONDEFORULTRASONICTESTMETHODS

链接地址:http://www.mydoc123.com/p-531650.html