《ASTM E2545-2007 Standard Test Method for Objective Measurement of Gingival Color Using Digital Still Cameras《用数字照相机测量齿龈客观颜色的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2545-2007 Standard Test Method for Objective Measurement of Gingival Color Using Digital Still Cameras《用数字照相机测量齿龈客观颜色的标准试验方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2545 07Standard Test Method forObjective Measurement of Gingival Color Using Digital StillCameras1This standard is issued under the fixed designation E 2545; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe color of gingiva is an important parameter used to ascertain certain medical and estheticinformation. RGB color
3、 values for gingiva are derived from the native signals generated by a digitalstill camera, DSC, by broadband measurement of the reflectance of gingiva. This test method, E 2545,specifies the procedure used for the color measurement of gingival color at 45 relative to the sampleplane containing the
4、gingiva under a nearly equal energy illuminating at 45 and viewing at 0. Thismethod is appropriate for evaluating the color of facial gingiva.1. Scope1.1 This test method covers the procedure, instrumentalrequirements, standardization procedures, material standards,measurement procedures, and parame
5、ters necessary to makeprecise measurements of gingival color. In particular it ismeant to measure the color of gingiva in human subjects.1.2 Digital images are used to evaluate gingival color on thefacial labial or buccal surfaces of the gingiva. The marginalgingival tissue adjacent to natural teeth
6、 may be of particularinterest for analysis.All other non-relevant parts; such as teeth,tongue, spaces, dental restorations or prostheses, etc., must beseparated from the measurement and the analysis.All localizeddiscoloration; such as stains, inclusions, pigmentations, etc.,may be separated from the
7、 measurement and the analysis.1.2.1 The broadband reflectance factors of gingiva and thesurrounding tissue are measured. The colorimetric measure-ment is performed using an illuminator(s) that provides con-trolled illumination on the gingiva using a digital still camerato capture the digital image.1
8、.3 Data acquired using this test method may be used toassess personal gingival color for the purposes of identifyingoverall health status, health status at specific sites in the mouth,or to track changes in personal health status for individualsover time. Pooled data may be used to assess gingival c
9、olor,health and disease among populations in epidemiologicalsurveys, evaluation of comparative product efficacy, or safetyand treatment response in clinical trials involving gingivalhealth or disease.1.4 The apparatus, measurement procedure, and data analy-sis technique are generic, so that a specif
10、ic apparatus, measure-ment procedure, or data analysis technique may not be ex-cluded.1.5 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.6 This standard does not purport to address all of thesafety concerns, if any, associat
11、ed with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 179 Guide for Selection of Geometric Conditions forMeasurem
12、ent of Reflection and Transmission Properties ofMaterialsE 284 Terminology of AppearanceE 308 Practice for Computing the Colors of Objects byUsing the CIE SystemE 1345 Practice for Reducing the Effect of Variability ofColor Measurement by Use of Multiple MeasurementsE 1767 Practice for Specifying th
13、e Geometries of Observa-tion and Measurement to Characterize the Appearance ofMaterials1This test method is under the jurisdiction of ASTM Committee E12 on Colorand Appearance and is the direct responsibility of Subcommittee E12.06 on ImageBased Color Measurement.Current edition approved May 1, 2007
14、. Published July 2007.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr
15、 Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.2.2 ISO Publications:3ISO 173211 Colour characterization of digital still cam-eras (DSCs) Part 1: Stimuli, metrology, and testproceduresISO/IEC 15441:2000 JPEG2000 Information technology JPEG 2000 image coding system Part 1:
16、 Core codingsystem, commonly known as JPEG 2000 jp2 file format2.3 ISCC Publications:4Technical Report 20031 Guide to Material Standards andTheir Use in Color Measurement2.4 Other Publications:5TIFF Tagged Image File Format3. Terminology3.1 Terms and definitions in Terminology E 284 are appli-cable
17、to this test method.3.2 Definitions: Terms included in this section are peculiarto this standard.3.2.1 angle of incidence, nu1and optional u2, the polarangle between the central ray of the illuminator(s), I1and I2,and the Z axis which is the optical axis of the camera.3.2.1.1 DiscussionThese are sho
18、wn in Fig. A1.1.3.2.2 bit depth, nthe number of digital bits used to storeinformation contained in each color channel of each pixel.3.2.2.1 DiscussionThe bit depth determines the maximumnumber of colors that may be encoded by the system. Forexample, a 24 bit system comprising 8 bits per channel cane
19、ncode 28by 28by 28or about 17 million; colors far more thanare distinguishable by the human observer.3.2.3 facial surfaces, nthe surfaces of teeth and gingivathat are oriented outward toward the lips (labial) and cheeks(buccal), and facing away from the tongue or roof of themouth.3.2.4 gingivitis, n
20、inflammation of the marginal gingiva inresponse to dental plaque accumulation on adjacent toothsurfaces.3.2.5 in-vivoadj, or adv, within a living body.3.2.5.1 DiscussionUsed to describe measurements madein a living body.3.2.6 polarization, nthe process by which vibrations oflight are given a definit
21、e orientation; also the state produced bythat process.3.2.7 polarizing filter, na component that blocks one ofthe two planes of vibration of an electromagnetic wave, thusproducing linearly polarized light.4. Summary of Test Method4.1 This test method describes the procedures for broadbandreflectomet
22、ry of gingival tissue. The standardization of theinstrument used to measure the tissue is defined. The images ofartifact standards and samples are captured with a DSC. TheRGB values of these images are read and stored. The results arereported as RGB values and can be converted to othercolorimetric c
23、oordinates such as CIELAB. Procedures forconverting the RGB camera values to component CIELABvalues are also presented.5. Significance and Use5.1 The color of gingiva or changes in gingival color can beobserved. The light reflected from the facial surfaces of thegingiva can be used to calculate colo
24、r coordinates. These datareveal information about the efficacy of a product, treatmentstudied, or epidemiology of anti-gingivitis treatments. Forexample, clinical studies of gingivitis treatment systems evalu-ate the efficacy of manufacturers products.5.2 The change in color of the facial surface gi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME25452007STANDARDTESTMETHODFOROBJECTIVEMEASUREMENTOFGINGIVALCOLORUSINGDIGITALSTILLCAMERAS 数字 照相机

链接地址:http://www.mydoc123.com/p-531370.html