ASTM E2544-2009 Standard Terminology for Three-Dimensional (3D) Imaging Systems.pdf
《ASTM E2544-2009 Standard Terminology for Three-Dimensional (3D) Imaging Systems.pdf》由会员分享,可在线阅读,更多相关《ASTM E2544-2009 Standard Terminology for Three-Dimensional (3D) Imaging Systems.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2544 09Standard Terminology forThree-Dimensional (3D) Imaging Systems1This standard is issued under the fixed designation E 2544; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in
2、 parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This terminology contains common terms, definitions ofterms, descriptions of terms, nomenclature, and acronymsassociated with three-dimensional
3、(3D) imaging systems in aneffort to standardize terminology used for 3D imaging systems.1.2 The definitions of the terms presented in 3.1 are ob-tained from various standard documents developed by variousstandards development organizations. The intent is not tochange these universally accepted defin
4、itions but to gather, ina single document, terms and their definitions that may be usedin current or future standards for 3D imaging systems.1.2.1 In some cases, definitions of the same term from twostandards have been presented to provide additional reference.The text in parentheses to the right of
5、 each defined term is thename (and, in some cases, the specific section) of the source ofthe definition associated with that term.1.3 The definitions in 3.2 are specific terms developed bythis committee for 3D imaging systems.1.4 A definition in this terminology is a statement of themeaning of a wor
6、d or word group expressed in a singlesentence with additional information included in notes ordiscussions.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety an
7、d health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1The subcommittee responsible for this standard will reviewdefinitions on a five-year basis to determine if the definition is stillappropriate as stated. Revisions will be made when determined necessary.2
8、. Referenced Documents2.1 ASTM Standard:2E 456 Terminology Relating to Quality and Statistics2.2 ASME Standard:3B89.4.19 Performance Evaluation of Laser Based SphericalCoordinate Measurement Systems2.3 ISO Standard:4VIM International Vocabulary of Basic and General Termsin MetrologyISO 111461 Lasers
9、 and laser-related equipment Testmethods for laser beam widths, divergence angles andbeam propagation ratios Part 1: Stigmatic and simpleastigmatic beams2.4 NIST/SEMATECH Standard:5NIST/SEMATECH e-Handbook of Statistical Methods3. Terminology3.1 Definitions:accuracy of measurement, ncloseness of the
10、 agreementbetween the result of a measurement and a true value of themeasurand. (VIM 3.5)DISCUSSION(1) Accuracy is a qualitative concept.(2) The term “precision” should not be used for “accuracy.”bias (of a measuring instrument), nsystematic error of theindication of a measuring instrument. (VIM 3.2
11、5)DISCUSSION(1) The bias of a measuring instrument is normallyestimated by averaging the error of indication over an appro-priate number of repeated measurements.bias, ndifference between the average or expected value of adistribution and the true value.(NIST/SEMATECH e-Handbook)DISCUSSION1This term
12、inology is under the jurisdiction of Committee E57 on 3D ImagingSystems and is the direct responsibility of Subcommittee E57.01 on Terminology.Current edition approved March 1, 2009. Published March 2009. Originallyapproved in 2007. Last previous edition approved in 2008 as E 2544 08b.2For reference
13、d ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Society of Mechanical Engineers (ASME), ASMEIntern
14、ational Headquarters, Three Park Ave., New York, NY 10016-5990, http:/www.asme.org.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.5Available from National Institute of Standards and Technology (NIST), 100Bureau Dr., Stop
15、 1070, Gaithersburg, MD 20899-1070, http:/www.nist.gov.e-Handbook available at http:/www.itl.nist.gov/div898/handbook/.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.(1) In metrology, the difference between precision andaccuracy is
16、that measures of precision are not affected by bias,whereas accuracy measures degrade as bias increases.calibration, nset of operations that establish, under specifiedconditions, the relationship between values of quantitiesindicated by a measuring instrument or measuring system, orvalues represente
17、d by a material measure or a referencematerial, and the corresponding values realized by standards.(VIM 6.11)DISCUSSION(1) The result of a calibration permits either the assignmentof values of measurands to the indications or the determinationof corrections with respect to indications.(2) A calibrat
18、ion may also determine other metrologicalproperties such as the effect of influence quantities.(3) The result of a calibration may be recorded in adocument, sometimes called a calibration certificate or acalibration pensation, nthe process of determining systematic er-rors in an instrument and then
19、applying these values in anerror model that seeks to eliminate or minimize measure-ment errors. (ASME B89.4.19)conventional true value (of a quantity), nvalue attributedto a particular quantity and accepted, sometimes by conven-tion, as having an uncertainty appropriate for a givenpurpose. (VIM 1.20
20、)DISCUSSION(1) Examples: (1) at a given location, the value assigned tothe quantity realized by a reference standard may be taken asa conventional true value and (2) the CODATA (1986) recom-mended value for the Avogadro constant, NA: 6 022 136 7 31023mol-1.(2) Conventional true value is sometimes ca
21、lled assignedvalue, best estimate of the value, conventional value, orreference value.(3) Frequently, a number of results of measurements of aquantity is used to establish a conventional true value.error (of measurement), nresult of a measurement minus atrue value of the measurand. (VIM 3.10)DISCUSS
22、ION(1) Since a true value cannot be determined, in practice, aconventional true value is used (see true value and conven-tional true value).(2) When it is necessary to distinguish “error” from“relative error,” the former is sometimes called “absolute errorof measurement.” This should not be confused
23、 with the“absolute value of error,” which is the modulus of error.indicating (measuring) instrument, nmeasuring instru-ment that displays an indication. (VIM 4.6)DISCUSSION(1) Examples include analog indicating voltmeter, digitalfrequency meter, and micrometer.(2) The display may be analog (continuo
24、us or discontinu-ous) or digital.(3) Values of more than one quantity may be displayedsimultaneously.(4) A displaying measuring instrument may also provide arecord.limiting conditions, nthe manufacturers specified limits onthe environmental, utility, and other conditions within whichan instrument ma
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。