《ASTM E2542-2008(2014) Standard Specification for Portable Water Heaters Used at Personnel Decontamination Stations《人员净化室用便携式水加热器的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2542-2008(2014) Standard Specification for Portable Water Heaters Used at Personnel Decontamination Stations《人员净化室用便携式水加热器的标准规范》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2542 08 (Reapproved 2014)Standard Specification forPortable Water Heaters Used at Personnel DecontaminationStations1This standard is issued under the fixed designation E2542; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revi
2、sion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification is used to standardize the portablewater heaters used on personnel decontaminatio
3、n lines toinsure the heaters provide sufficient heated water for as long asthey are needed during the emergency.NOTE 1These heaters are not intended to be used for the decontami-nation for any other surface or material. Also, these heaters are intendedto be portable and easy to use by first responde
4、rs during a chemical,biological, radiological, nuclear, and explosive (CBRNE) event.1.2 This specification contains a specification section and atest methods section so users need to refer to the sectionapplicable to their needs when using this standard specifica-tion.1.3 The values stated in SI uni
5、ts are to be regarded asstandard. The values given in parentheses are for informationonly.NOTE 2The U.S. first responder personnel using the equipmentmanufactured under this standard are not likely to be familiar with SI unitsso English units need to be included as part of the system documentationan
6、d shown on control panels for any equipment sold to U.S. organizations.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine th
7、e applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D3195 Practice for Rotameter CalibrationE11 Specification for Woven Wire Test Sieve Cloth and TestSieves2.2 ASME Standards:3Boiler and Pressure Vessel CodeMFC-3M Measurement of Fluid Flow in Pipes Usin
8、gOrifice, Nozzle, and Venturi2.3 NFPA Standard:4NFPA 70 National Electrical Code2.4 NIST Standard:5Recommended Practice Guide Special Publication 960-12 Stopwatch and Timer Calibrations3. Terminology3.1 Definitions:3.1.1 decontamination, nprocess of reducing or eliminat-ing the hazards associated wi
9、th chemical, biological, or radio-logical contamination.3.1.1.1 DiscussionThe means of decontaminatingpersonnel, equipment, or areas include absorption,neutralization, weathering, and physical removal of the con-taminant and hazards associated with nuclear, biological, orchemical (NBC) agents.4. Cla
10、ssification4.1 There will be no attempt to classify into categories thedifferent types of portable water heaters that can fall under thisspecification since this specification will only address theminimum requirements these heaters must satisfy.5. Ordering Information5.1 Personnel ordering portable
11、water heaters using thisspecification as a basis for their order should be aware that thisspecification is the minimum requirement for these types ofdevices and any needs beyond these minimum requirementsshall be stated in the request for quote.1This specification is under the jurisdiction of ASTM C
12、ommittee E54 onHomeland Security Applications and is the direct responsibility of SubcommitteeE54.03 on Decontamination.Current edition approved June 1, 2014. Published June 2014. Originallyapproved in 2008. Last previous edition approved in 2008 as E2542 08. DOI:10.1520/E2542-08R14.2For referenced
13、ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Society of Mechanical Engineers (ASME), ASMEInternat
14、ional Headquarters, Two Park Ave., New York, NY 10016-5990, http:/www.asme.org.4Available from National Fire Protection Association (NFPA), 1 BatterymarchPark, Quincy, MA 02169-7471, http:/www.nfpa.org.5Available from National Institute of Standards and Technology (NIST), 100Bureau Dr., Stop 1070, G
15、aithersburg, MD 20899-1070, http:/www.nist.gov.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Materials and Manufacture6.1 The hot water tanks of the portable water heaterspurchased under this specification shall conform to the re
16、quire-ments of the current version of the ASME Boiler and PressureVessel Code.7. Mechanical Properties7.1 The heater materials of construction shall be easilycleaned of surface mud and grime with no degradation of theunits ability to perform its function.7.2 The preferred fuels for the heater sectio
17、n of the portablewater heater are diesel fuel, gasoline, or bottled propane gas. Ifelectricity is used, the circuit shall be no more than 120 V, 30A, single phase, and shall conform to NFPA 70 for outdoorusage.8. Performance Requirements8.1 Using the input flows shown in Table 1, a continuousflow (2
18、5 to 60 L/min 6.6 to 15.9 gal/min) of warm water(between 13 and 27C 55 and 80F) is provided at a pressurebetween 275 and 620 kPa (40 and 90 lb/in.2) at each of theinput conditions.8.2 Be capable of providing a warm water flow within thetemperature range specified in 8.1 within 2 min of beingsupplied
19、 2C (36F) feed water.8.2.1 Use 4-cm (1.5-in.) National Pipe Thread connectors(preferably female) to receive the input water and discharge theoutlet water. The input lines shall be filtered using anASTM 18sieve. The sieve shall be certified under Specification E11 toremove solid debris particles that
20、 might damage the equipmentor injure the personnel undergoing the decontaminationshower.NOTE 3As specified, the inlet filter is not intended to protect againstchemical and biological warfare agents. The sole intended purpose of theinlet filter is to protect the water heater device from debris that m
21、ay beattracted to it because of the suction of the inlet.9. Other Requirements9.1 Contain sufficient hoses as part of the unit packaging toconnect to a water source up to 15.24 m (50 ft) distant andprovide warm water to a shower up to 7.62 m (25 ft) from theunit.10. Dimensions, Mass, and Permissible
22、 Variations10.1 The unit shall be man-transportable by not more thanfour first responders carrying the assembled unit and not weighmore than 91 kg (200 lb) not including the fuel and hoses.TEST METHODS11. Scope11.1 These test methods shall be used to insure portablewater heaters comply with the requ
23、irements of this specifica-tion.12. Significance and Use12.1 The use of these acceptance tests will insure thatorganizations buying portable heaters will be assured theheaters meet certain performance requirements.13. Hazards13.1 Personnel using this portable water heater should takeprecautions agai
24、nst normal industrial hazards, such as fire andtemperature hazards or accumulation of exhaust. They shallalso comply with all other manufacturers warnings whenusing the equipment.14. Procedure14.1 Measurement of the Water Heater Units Water FlowThe water heater units water flow shall be measured, an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME254220082014STANDARDSPECIFICATIONFORPORTABLEWATERHEATERSUSEDATPERSONNELDECONTAMINATIONSTATIONS 人员

链接地址:http://www.mydoc123.com/p-531357.html