ASTM E2193-2004 Standard Test Method for Ultraviolet Transmittance of Monoethylene Glycol (Ultraviolet Spectrophotometric Method)《单乙二醇的紫外线透射率的标准试验方法(紫外线光谱测定法)》.pdf
《ASTM E2193-2004 Standard Test Method for Ultraviolet Transmittance of Monoethylene Glycol (Ultraviolet Spectrophotometric Method)《单乙二醇的紫外线透射率的标准试验方法(紫外线光谱测定法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2193-2004 Standard Test Method for Ultraviolet Transmittance of Monoethylene Glycol (Ultraviolet Spectrophotometric Method)《单乙二醇的紫外线透射率的标准试验方法(紫外线光谱测定法)》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2193 04Standard Test Method forUltraviolet Transmittance of Monoethylene Glycol(Ultraviolet Spectrophotometric Method)1This standard is issued under the fixed designation E 2193; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a procedure for the determina-tion of the transmittance of monoethylen
3、e glycol (1,2-ethanediol; MEG) at wavelengths in the region 220 to 350 nm.The results provide a measure of the purity of the sample withrespect to ultraviolet absorbing compounds.1.2 The values stated in SI units are to be regarded as thestandard.1.3 This standard does not purport to address all of
4、thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.4 Review the current Material Safety Data Sheets (MSDS)for detaile
5、d information concerning toxicity, first aid proce-dures, and safety precautions.2. Referenced Documents2.1 ASTM Standards:2E 131 Terminology Relating To Molecular SpectroscopyE 169 Practices for General Techniques of Ultraviolet-Visible Quantitative AnalysisE 180 Practice for Determining the Precis
6、ion of ASTMMethods for Analysis and Testing of Industrial ChemicalsE 275 Practice for Describing and Measuring Performanceof Ultra-violet, Visible and Near Infrared Spectrophotom-eters2.2 Other Document:Manufacturers Instruction Manual of Spectrophotometer3. Summary of Test Method3.1 The product is
7、sampled in such a way as to avoidextraneous contamination and air contact. The absorbance ofthe sample contained in a 50-mm or 10-mm cell is measuredagainst water at a series of wavelengths and the transmittanceover a pathlength of 10 mm is calculated.3.2 This test method can be performed with two o
8、ptions asto sample preparation prior to UV measurement.3.2.1 Option A: Nitrogen sparging of the sample (see 4.2).3.2.2 Option B: No nitrogen sparging.4. Significance and Use4.1 Knowledge of the ultraviolet transmittance of monoet-hylene glycol is required to establish whether the productmeets the re
9、quirements of its quality specifications.4.2 Dissolved oxygen in organic solvents, such as MEG,forms complexes that shift the solvent absorption from thevacuum ultraviolet range into the measurable UV range (near190 to 250 nm). Monoethylene glycol has a UV absorptionpeak at 180 nm. For MEG-oxygen co
10、mplexes, this peak isshifted to a longer wavelength, thus increasing the absorbabil-ity at 220 nm.4.2.1 However, this effect is not observed in water. There isno significant measurable effect due to dissolved oxygen inwater that would require nitrogen sparging prior to using forcollection of the ref
11、erence spectrum.4.2.2 Nitrogen sparging and re-measurement of suspect orborderline glycol samples at 220 nm can be used as a tool torule out or confirm the presence of UV affecting contaminantsother than oxygen.5. Apparatus5.1 Ultraviolet Spectrophotometer, double beam, suitablefor measurement at wa
12、velengths in the region 200 to 400 nm,having a spectral bandwidth of 2.0 nm or less at 220 nm,wavelength accuracy 60.5 nm or less at 220 nm, wavelengthrepeatability 0.3 nm or less at 220 nm and a photometricaccuracy of 60.5 % T or less, in the transmittance regionabove 50 % T. Stray light shall be l
13、ess than 0.1 % at 220 nm.The instrument shall be provided with matched fused silicacells with pathlengths of 50 6 0.1 mm or 10 mm 6 0.01 mm.Use of 50-mm cell should provide better precision.5.1.1 Optional Single Beam SpectrophotomerUse thesame cell for measurement of the blank and the sample.1This t
14、est method is under the jurisdiction of ASTM Committee E15 onIndustrial and Specialty Chemicals and is the direct responsibility of SubcommitteeE15.02 on Product Standards.Current edition approved Oct. 1, 2004. Published November 2004. Originallypublished as E 2193-02. Last previous edition E 2193-0
15、2a.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO B
16、ox C700, West Conshohocken, PA 19428-2959, United States.5.2 Nitrogen Stripping Apparatus (Option A, 3.2.1), consist-ing of an oil-free pressure reducing valve to fit the nitrogencylinder, a control valve, vinyl tubing and a disposable glasspipette to be inserted in a 25-mL volumetric flask. Compone
17、ntsshould be clean and free of ultraviolet contaminants. Avoidcontacting the sample with any plastic material containingplasticizers. Plasticizers can leach out of the material and causeerroneous results. Replace the disposable pipette by a clean,new one after each sample handling. (See Section 9.)5
18、.3 Bottles, capacity at least 0.5L, with lined, well-fittingcap. Use a fresh bottle for each determination.5.4 Glassware:5.4.1 Volumetric Flask, 25-mL.6. Reagents and Materials6.1 Purity of ReagentsUnless otherwise indicated, it isintended that all reagents shall conform to the specifications ofthe
19、Committee on Analytical Reagents of the American Chemi-cal Society where such specifications are available.3Othergrades may be used, provided it is first ascertained that thereagent is of sufficiently high purity to permit its use withoutlessening the accuracy of the determination.6.2 Holmium Oxide
20、Wavelength Calibration Filter, cali-brated (if required; see 8.1.1).NOTE 1The standard reference material SRM 2034, available fromthe National Institute of Standards and Technology (NIST),4is suitable.6.3 Standard Absorbance Filter, with certified absorbancevalues (if required; see 8.1.2).NOTE 2The
21、standard reference material SRM 2031, available fromNIST,4is suitable. In addition, SRM 935a may be used (see 6.4).6.4 Stray Light Filter, for measuring stray light at 220 nm (ifrequired; see 8.1.3).NOTE 3The (potassium iodide) standard reference material SRM2032, available from NIST,4is suitable (s
22、ee also 6.8).6.5 Naphthalene Solution(1 mg/L isooctane) Dissolve 1mg naphthalene in 1000 mL of spectroscopic grade isooctane.(WarningIsooctane is highly flammable and irritating to therespiratory system. Avoid contact with skin. Naphthalene isirritating to the skin, eyes, and respiratory system. It
23、may causesensitization by skin contact. Avoid contact with eyes. Wearsuitable protective clothing.6.6 Nitrogen, minimum purity 99.99 % (V/V), oil-free.6.7 Potassium Dichromate or Potassium Chromate, forchecking photometric accuracy (if required; see 8.1.2).NOTE 4The standard reference material, no.
24、SRM 935a, availablefrom NIST,4is suitable.(WarningPotassium dichromate is harmful in contactwith skin, toxic if swallowed, and very toxic by inhalation. Itis irritating to the respiratory system and skin. Risk of seriousdamage to eyes. It may cause sensitization by skin contact. Itmay cause heritabl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME21932004STANDARDTESTMETHODFORULTRAVIOLETTRANSMITTANCEOFMONOETHYLENEGLYCOLULTRAVIOLETSPECTROPHOTOMETRICMETHOD

链接地址:http://www.mydoc123.com/p-530517.html