《ASTM E1967-1998(2003) Standard Test Method for the Automated Determinaton of Refractive Index of Glass Samples Using the Oil Immersion Method and a Phase Contrast Microscope《用油浸法和相.pdf》由会员分享,可在线阅读,更多相关《ASTM E1967-1998(2003) Standard Test Method for the Automated Determinaton of Refractive Index of Glass Samples Using the Oil Immersion Method and a Phase Contrast Microscope《用油浸法和相.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1967 98 (REapproved 2003)Standard Test Method forthe Automated Determination of Refractive Index of GlassSamples Using the Oil Immersion Method and a PhaseContrast Microscope1This standard is issued under the fixed designation E 1967; the number immediately following the designation i
2、ndicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a procedure fo
3、r measuring therefractive index (hlt) of glass samples, irregularly shaped andas small as 300 g, for the comparison of fragments of a knownsource to recovered fragments from a questioned source.1.2 This test method does not include the measurement ofoptical dispersion or the measurement of refractiv
4、e index (hlt)at any other wavelength other than the Sodium D line (hDt).This method employs a narrow band pass filter at 589 nm, butother filters could be employed using the described method andallowing the hltto be determined at other wavelengths,therefore, also allowing for the dispersion value to
5、 be calcu-lated.1.3 Alternative methods for the determination of hltarelisted in Refs (1-5).21.4 This standard test method does not purport to addressall of the safety concerns, if any, associated with its use. It isthe responsibility of the user to establish appropriate safetyand health practices a
6、nd determine the applicability of regu-latory limitations prior to use.2. Summary of Test Method2.1 A phase contrast microscope is employed with illumi-nation at a fixed wavelength (nominally Sodium D) to magnifythe image of glass particles while these are immersed in asilicone oil. The microscope i
7、s aligned to produce evenillumination with maximum contrast and a video camera isattached to an eyepiece (the output of the image) to observe theimmersed glass and measure the contrast of the image of theglass. The temperature of the oil is changed via a hot stage andan electronic temperature contro
8、ller until the glass particlesimage disappears. The temperature at which there is minimumcontrast between the glass and the liquid then is recordedmanually or electronically.2.2 A microprocessor or other handling station, such as apersonal computer, employs a video camera interfaced byappropriate so
9、ftware and hardware to view the glass fragments.These commercial electronics result in a digital count repre-senting a preselected edge features contrast being determined.This edge or contrast measurement is updated with every frameof video as the temperature of the hot stage, oil, and sample areram
10、ped up or down. The software automatically registers thematch point by taking the average of the minimum contrastmeasurements for both the cooling and the heating cycles. Thismatch temperature can be converted to hDtby reference to acalibration curve for the immersion oil previously created fromthe
11、match temperatures obtained on reference glass standards.This calibration curve is obtained from reference glasses ofknown hDt,s within the range of interest. This curve or itsmathematical equivalent normally is stored within the micro-processor and is employed to determine the hDtof any glass ofint
12、erest, whether it is a fragment of known origin or arecovered (questioned) fragment.2.3 Precise control and measurement of the immersionliquid temperature is achieved by use of a microscope hotstage. A precision of 0.05C for the hot stage is desirable, buta precision of 0.1C is the requirement for i
13、nterlaboratorycomparisons.3. Significance and Use3.1 This technique modifies the sample, in that the glassfragment must be crushed, if it is too large, and immersed in oilfor the analysis. Some sample handling, however, wouldenable the analyst to recover the sample in the crushed form, ifnecessary.3
14、.2 This test method is useful for accurate measurement ofhDtfrom a wide variety of glass samples, where most glassesof interest have hDtin the range between 1.48 1.55 in hDtunits.3.3 The objective nature of the match point determinationallows for a better standardization between laboratories, andthe
15、refore, allows for the interchange of databases betweenlaboratories.1This practice is under the jurisdiction of ASTM Committee E30 on ForensicSciences and is the direct responsibility of Subcommittee E30.01 on Criminalistics.Current edition approved Nov. 10, 1998. Published January 1999.2The boldfac
16、e numbers in parentheses refer to the list of references at the end ofthis standard.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.4 It should be recognized that surface fragments, espe-cially from float glass samples, can result
17、in hDt,s measurablyhigher than fragments from the bulk of the same source (5).3.5 The precision and bias of this test method should beestablished in each laboratory that employs it. Confidenceintervals or a similar statistical quality statement should bequoted along with any reported hDtvalue. For i
18、nstance, alaboratory may report that the error for the measurement, usinga reference optical glass is 0.00003 units.3.6 It should be recognized that this technique measures therefractive index of the glass at the match point temperature,which will be higher than ambient temperature, and thus, maygiv
19、e different hDtvalues from those obtained by other methods,which measure the refractive index at room temperature.4. Apparatus4.1 MicroscopeA microscope outfitted for phase contrastand an appropriate objective (nominally 103 -403) with along working distance condenser is employed.4.2 Temperature Con
20、trolA hot stage connected to a con-trol device with a working range of approximately 26C to118C, having a minimum precision of 0.1C is employed.34.3 ImagingA video camera is required for the automatedmeasurements and is mounted to an ocular or photography portof the microscope. The output from the c
21、amera is used for theimage processing for automated match point determinations.4.4 IlluminationA narrow band interference filter is em-ployed as a monochromatic source. For Sodium D measure-ments 589 6 5 nm with a band pass of 10 nm is appropriate.The intensity of the illumination is adjusted to giv
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME196719982003STANDARDTESTMETHODFORTHEAUTOMATEDDETERMINATONOFREFRACTIVEINDEXOFGLASSSAMPLESUSINGTHEOILIMMERSIONMETHODANDAPHASECONTRASTMICROSCOPE

链接地址:http://www.mydoc123.com/p-529943.html