1、Designation: E1746 08E1746 17Standard Test Method forSampling and Analysis of Liquid Chlorine for GaseousImpurities1This standard is issued under the fixed designation E1746; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers sampling and analysis of liquid chlorine for the determination of oxygen (200 to 400 g/g)
3、, nitrogen(400 to 800 g/g), and carbon dioxide (800 to 1000 ppm) content at levels normally seen in liquid chlorine. Hydrogen and carbonmonoxide concentrations in liquid chlorine are typically at or below the detection limit of this test method.NOTE 1The minimum detection limit of hydrogen using a 1
4、 cm3 gas sample and argon carrier gas is 100 to 200 g/g.2 The detection limit for theother components is significantly lower.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 Review the current Material Safety Data Sheet
5、s (MSDS)(SDS) for detailed information concerning toxicity, first aidprocedures, and safety precautions.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and
6、health practices and determine the applicability of regulatorylimitations prior to use. Specific hazards statements are given in Section 7.2. Referenced Documents2.1 Code of Federal Regulations:349 CFR 173, Code of Federal Regulations Title 49, Transportation: Shippers General Requirements for Shipm
7、ents andPackaging, including the following sections:173.304 Charging of Cylinders with Liquefied Compressed Gas173.314 Requirements for Compressed Gases in Tank Cars173.315 Compressed Gases in Cargo Tanks and Portable Tank Containers2.2 Other Document:Chlorine Institute Pamphlet No. 771 Sampling Liq
8、uid ChlorineChlorine Basics43. Summary of Test Method3.1 A sample of liquid chlorine is trapped in a sampling tube and vaporized into a steel bomb. The vaporized chlorine in thesteel bomb is introduced into a gas chromatograph by a gas sampling loop (1 cm3) using a ten-port gas sampling and switchin
9、gvalve. The separations are made on a PorapakPorapak5 Q column and on a 5A molecular sieve column whose lengths are suchthat the peaks do not overlap.3.2 Any component that co-elutes with the components of interest may interfere with this analysis.4. Significance and Use4.1 It is very difficult to e
10、xclude sample contamination by ambient air during the process of sampling. The levels of atmosphericcontamination caused by poor sampling methods are often equal to or larger than the levels of the gaseous impurities present in1 This test method is under the jurisdiction of ASTM Committee D16 on Aro
11、matic Hydrocarbons and Related Chemicals and is the direct responsibility of SubcommitteeD16.16 on Industrial and Specialty Product Standards.Current edition approved Dec. 15, 2008March 1, 2017. Published January 2009March 2017. Originally approved in 1995. Last previous edition approved in 20012008
12、as E1746 95 (2001)08. 1. DOI: 10.1520/E1746-08.10.1520/E1746-17.2 Thompson, B., Fundamentals of Gas Chromatography, Varian Instruments Division, Sunnyvale, CA, p. 73.3 Available from Standardization Documents Order Desk, Bldg. 4 Section D, DLA Document Services, Building 4/D, 700 Robbins Ave., Phila
13、delphia, PA 19111-5094,Attn: NPODS.http:/quicksearch.dla.mil.4 Available from The Chlorine Institute, Inc., 2001 L Street NW, Washington, DC 20036-4919.1300 Wilson Blvd., Suite 525, Arlington, VA 22209.5 Porapak is a trademark of Waters Associates, Inc.This document is not an ASTM standard and is in
14、tended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the cur
15、rent versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1the chlorine. This results in
16、markedly elevated levels of detected impurities. As specifications become tighter, it becomes moreimportant to measure the gaseous impurity levels in liquid chlorine correctly.4.2 Additional problems are experienced in the sampling of liquefied gases for the gaseous impurities. The gaseous impuritie
17、sreach an equilibrium between the liquid phase and vapor phase in a sample bomb. The quantity of gases measured in any particularsample containing both liquid and vapor will be a function of the amount of vapor space in the sample bomb. This test methodavoids the presence of liquid in the sample bom
18、b.5. Apparatus5.1 Gas ChromatographShimadzu GC-8AITequipped as shown in Fig. 1, or equivalent, equipped with a thermal conductivitydetector.5.2 Recorder, 1 mV, 0.5 s full-scale response.5.3 Valve Sequencer and Actuator, for switching valve control.5.4 Switching Valves.5.4.1 Ten-Port Switching and Sa
19、mpling Valve (stainless steel is acceptable).5.4.2 Four-Port Switching Valve (stainless steel is acceptable).FIG. 1 Chlorine Impurity Analysis System Flow DiagramE1746 1725.5 Chromatographic Columns, 3.2-mm outside diameter, 316 stainless, as follows:5.5.1 2 m of 80/100 mesh PorapakPorapak N,65.5.2
20、0.8 m of 80/100 mesh ShimaliteShimalite Q,75.5.3 1 m of 80/100 mesh ShimaliteShimalite Q,75.5.4 0.8 m of 80/100 mesh ShimaliteShimalite Q,75.5.5 3 m of 45/60 mesh molecular sieve 5A,5.5.6 2 m of 80/100 mesh PorapakPorapak Q,65.5.7 2 m of 80/100 mesh PorapakPorapak N,6 and5.5.8 1 m of 45/60 mesh mole
21、cular sieve 5A.5.6 Tantalum Tubing, 1.6-mm outside diameter, 0.57-mm inside diameter.NOTE 2Nickel tubing may be substituted for tantalum.5.7 MonelMonel Sampling Tube, 9.5 by 140-mm long (volume 5.4 cm3).85.8 Electronic Integrator, or computer integration package.5.9 TFE-Fluorocarbon Lined Flex Tubin
22、g, 6.35 mm.5.10 TFE-Fluorocarbon Tubing, 6.35 mm by 3.05 m.5.11 CajonCajon VCR Fitting. 95.12 Two-Valves, 9.5 mm, Monel.Monel.85.13 Four-Valves, 6.35-mm tubing to 6.35-mm pipe, Monel.Monel.85.14 HokeHoke10 Sample Cylinder, 1000 cm3, Monel,8 nickel, tantalum, or stainless steel.5.15 Pressure Gage, 91
23、 kg, Monel.Monel.85.16 Four-Pipe Tee, 6.35 mm, Monel.Monel.85.17 Vacuum Source, suitable for chlorine disposal.6. Reagents6.1 Gas Standard, 500 g/g H2, 400 g/g O2, 800 g/g N2, 50 g/g CO, and 1000 g/g CO2 in argon.116.2 Argon Carrier Gas, chromatographic grade.7. Hazards7.1 Safety Precautions:7.1.1 C
24、hlorine is a corrosive and toxic material. A well-ventilated fume hood should be used to house all sample handling andto vent the test equipment when this product is analyzed in the laboratory.7.1.2 The analysis should be attempted only by individuals who are thoroughly familiar with the handling of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME17462017STANDARDTESTMETHODFORSAMPLINGANDANALYSISOFLIQUIDCHLORINEFORGASEOUSIMPURITIES 气态 杂质 取样 分析

链接地址:http://www.mydoc123.com/p-529372.html