ASTM E1491-2006(2012) Standard Test Method for Minimum Autoignition Temperature of Dust Clouds《尘雾最低自燃温度的标准试验方法》.pdf
《ASTM E1491-2006(2012) Standard Test Method for Minimum Autoignition Temperature of Dust Clouds《尘雾最低自燃温度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1491-2006(2012) Standard Test Method for Minimum Autoignition Temperature of Dust Clouds《尘雾最低自燃温度的标准试验方法》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1491 06 (Reapproved 2012)Standard Test Method forMinimum Autoignition Temperature of Dust Clouds1This standard is issued under the fixed designation E1491; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method covers the determination of the minimum temperature at which a dust cloud willautoignite. The dust clo
3、ud is exposed to air heated to various temperatures in a furnace. Ignition of thecloud is indicated by visual observation of the flame. The chemical nature of the dust as well as itsconcentration, particle size, moisture, and surface area affects the results.1. Scope1.1 This test method covers the m
4、inimum temperature atwhich a given dust cloud will autoignite when exposed to airheated in a furnace at local atmospheric pressure.1.2 Data obtained from this test method provide a relativemeasure of dust cloud autoignition temperatures.1.3 This test method should be used to measure and describethe
5、properties of materials, products, or assemblies in responseto heat and flame under controlled laboratory conditions andshould not be used to describe or appraise the fire hazard or firerisk of materials, products, or assemblies under actual fireconditions. However, results of this test method may b
6、e used aselements of a fire risk assessment which takes into account allof the factors which are pertinent to an assessment of the firehazard of a particular end use.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 This s
7、tandard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.
8、1 ASTM Standards:2D3173 Test Method for Moisture in the Analysis Sample ofCoal and CokeD3175 Test Method for Volatile Matter in the AnalysisSample of Coal and CokeE659 Test Method for Autoignition Temperature of LiquidChemicalsE1226 Test Method for Explosibility of Dust Clouds3. Terminology3.1 Defin
9、itions of Terms Specific to This Standard:3.1.1 dust concentrationthe mass of dust divided by theinternal volume of the test chamber.3.1.2 minimum autoignition temperature (MAIT)the mini-mum temperature at which a dust cloud will self ignite underthe specified conditions of test.4. Summary of Test M
10、ethod4.1 The temperature of the furnace or oven is set at apredetermined value.4.2 Dust is blown into the heated furnace, which is atambient pressure.4.3 Ignition is determined by visual observation of the flameexiting the furnace.5. Significance and Use5.1 This test method provides a procedure for
11、performinglaboratory tests to determine the minimum autoignition tem-perature (MAIT) of a dust cloud.5.2 The test data developed from this test method can beused to limit the temperature to which a dust cloud is exposedso as to prevent ignition of the cloud. Because of the shortduration of the test,
12、 the data obtained are most applicable toindustrial equipment where dust is present as a cloud for a shorttime. Because of the small scale of the test and the possible1This test method is under the jurisdiction of ASTM Committee E27 on HazardPotential of Chemicals and is the direct responsibility of
13、 Subcommittee E27.05 onExplosibility and Ignitability of Dust Clouds.Current edition approved Dec. 1, 2012. Published December 2012. Originallyapproved in 1991. Last previous edition approved in 2006 as E1491 06. DOI:10.1520/E1491-06R12.2For referenced ASTM standards, visit the ASTM website, www.ast
14、m.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1variation
15、of the MAIT value with scale, the data obtained bythis test method may not be directly applicable to all industrialconditions.5.3 The MAIT data can also be used in conjunction withminimum spark ignition data to evaluate the hazards ofgrinding and impact sparks in the presence of dust clouds (1and 2)
16、.35.4 The test values obtained are specific to the sampletested, the method used, and the test equipment utilized. Thetest values are not to be considered intrinsic material constants,but may be used as a relative measure of the temperature atwhich a dust cloud self ignites.5.5 The test data are for
17、 cloud ignition. Dust in the form ofa layer may ignite at significantly lower temperatures than thesame dust in the form of a cloud (3). For liquid chemicals, seeTest Method E659.6. Interferences6.1 Unburned dust from a previous test may affect results. Ifthere is a question, the furnace should be h
18、eated to itsmaximum temperature to clean it before future tests are made.6.2 The material of construction of this test method mayhave catalytic effects on the ignition and should be consideredduring testing.7. Apparatus7.1 The equipment consists of a heated chamber closed witha frangible diaphragm,
19、or flap vent, or a hole open to theatmosphere.7.2 The chamber is insulated and provided with a thermo-statically controlled electric heater. A thermocouple measuresthe set temperature of the chamber.7.3 A dust dispersion system generates a fairly uniform dustcloud within the chamber. There should be
20、 a minimal amountof dust remaining in the disperser after the test.7.4 Athermocouple (1 mil or 25 m) and a recording systemhaving a fast enough response may be used to measure thetemperature rise during ignition of the dust cloud in thechamber.7.5 Examples of chambers and specific procedures that ha
21、vebeen found suitable are listed in chronological order inAppendix X1-Appendix X4.8. Hazards8.1 Safety Precautions:8.1.1 Prior to handling a dust, its toxicity and the toxicity ofits combustion products must be considered. This informationcan usually be obtained from the manufacturer. Considerationw
22、ill have to be given to ventilation, use of hoods, personalprotective gear, and procedures.8.1.2 Explosive, highly reactive, or easily decomposed ma-terials should not be tested unless they have been characterizedby prior testing. Procedures such as the use of barricades,hoods, and personal protecti
23、ve equipment should be used asjudgment indicates.8.1.3 Electrical systems must be grounded.9. Sampling9.1 It is not practical to specify a single method of samplingdust for test purposes because the character of the material andits available form affect selection of the sampling procedure.Generally
24、accepted sampling procedures should be used asdescribed in STP 447A.49.2 Tests may be run on an as-received sample. However,due to the possible accumulation of fines at some location in aprocessing system, it is recommended that the test sample be atleast 95 % minus 200 mesh (75 m).9.3 To achieve th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME149120062012STANDARDTESTMETHODFORMINIMUMAUTOIGNITIONTEMPERATUREOFDUSTCLOUDS 尘雾 最低 自燃 温度 标准 试验 方法

链接地址:http://www.mydoc123.com/p-528800.html