ASTM E1237-1993(2003) Standard Guide for Installing Bonded Resistance Strain Gages《安装耦合电阻应变仪》.pdf
《ASTM E1237-1993(2003) Standard Guide for Installing Bonded Resistance Strain Gages《安装耦合电阻应变仪》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1237-1993(2003) Standard Guide for Installing Bonded Resistance Strain Gages《安装耦合电阻应变仪》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1237 93 (Reapproved 2003)Standard Guide forInstalling Bonded Resistance Strain Gages1This standard is issued under the fixed designation E 1237; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This document provides guidelines for installin
3、g bondedresistance strain gages. It is not intended to be used for bulk ordiffused semiconductor gages. This document pertains only toadhesively bonded strain gages.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of th
4、e user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:E 251 Test Methods for Performance Characteristics ofMetallic Bonded Resistance Strain Gages22.2 Other Stand
5、ards:ANSI/SEM 1-1984; Standard for Portable Strain-IndicatingInstrumentsDesignation of Strain Gage Bridge andColor Code of Terminal Connections; August 16, 1984.33. Terminology3.1 Definitions:3.1.1 lead wirean electrical conductor used to connect asensor to its instrumentation.3.1.2 resistance strai
6、n gage bridgea commonWheatsone bridge made up of strain gages used for themeasurement of small changes of resistance produced by astrain gage, where the gages may be wired in the followingconfiguration (see also Fig. 1 and Fig. 2):Arm 1 between + excitation and signalArm 2 between excitation and sig
7、nalArm 3 between + signal and excitationArm 4 between + signal and + excitation3.2 Definitions of Terms Specific to This Standard:3.2.1 bonded resistance strain gagea resistive elementwith a carrier that is attached by bonding to the base materialso that the resistance of the element will vary as th
8、e surface ofthe base material to which it is attached is deformed. (For acomplete definition of this term see Test Methods E 251.)4. Significance and Use4.1 Methods and procedures used in installing bondedresistance strain gages can have significant effects upon theperformance of those sensors. Opti
9、mum and reproducibledetection of surface deformation requires appropriate andconsistent surface preparation, mounting procedures, and veri-fication techniques.5. Gage Selection5.1 Careful consideration must be given to the intended usewhen selecting an appropriate gage. Installation and operatingcha
10、racteristics of a gage are affected by many factors such asresistive element alloy, carrier material, gage length, gage and1This guide is under the jurisdiction of ASTM Committee E28 on MechanicalTesting and is the direct responsibility of Subcommittee E28.01 on Calibration ofMechanical Testing Mach
11、ines and Apparatus.Current edition approved June 10, 2003. Published January 2004. Originallyapproved in 1993. Last previous edition approved in 1998 as E123793(1998).2Annual Book of ASTM Standards, Vol 03.01.3Available from American National Standards Institute, 11 W. 42nd St., 13thfloor, New York,
12、 NY 10036.FIG. 1 Designation of Strain Gage Bridge and Color Code of LeadWires (Full Bridge)FIG. 2 Designations of Strain Gage Bridge and Color Code ofLead Wires (14 Bridge)1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.resistive el
13、ement pattern, solder tab type and configuration,temperature compensation characteristics, resistance of activeelements, gage factor, and options desired.5.2 Factors that should also be considered include type oftest or application, operating temperature range, environmentalconditions, accuracy requ
14、irements, stability, maximum elonga-tion, test conditions (static or dynamic) and duration, andsimplicity and ease of installation. Dissipation of self-generated heat to the carrier should be considered in selectinggage resistance and size of grid.5.3 To minimize errors due to strain gradients over
15、the gagearea, gage size should normally be small with respect to thedimensions of an immediately adjacent geometric irregularity(hole, fillet, etc.). However, the gage size should generally belarge relative to the underlying material structure (grain size,fabric-reinforced composite weave pattern, e
16、tc.).5.4 A two- or three-element rosette gage should be usedunless the strain state is unquestionably uniaxial. A singleelement gage may be selected to measure the strain due to auniaxial strain state if the principal directions are known.5.5 Temperature compensation of the gage should be se-lected
17、to match the thermal coefficient of expansion of the basematerial, where possible. As a note of caution, for extremetemperature changes, nominal or handbook data on the thermalexpansion characteristics of the base material may not besufficiently accurate, and actual calibration may be required.5.6 S
18、train gage manufacturers provide detailed critiques ofthe various factors which affect gage selection (1).45.7 For nonroutine applications, the advice of experiencedusers and of strain gage manufacturers should be sought.Specific verification tests may be required to ensure accurateresults.6. Bondin
19、g Technique Selection6.1 Selection of the proper bonding technique and agent isimportant. Because the bonding agent becomes part of thestrain gage system, many of the gage selection factors shouldbe considered in bonding technique or agent selection.6.2 Additional selection factors include compatibi
20、lity of thebonding materials used in the selected gage construction withthe material under test, environmental conditions, and availableinstallation time.6.3 Strain gages from different manufacturers may differ.Generally, each manufacturer will supply instructions andrecommendations for bonding. The
21、se instructions should beconsidered when making a selection.7. Surface Preparation7.1 The surface must be properly prepared to ensure goodbonding. Surface preparation includes solvent degreasing,cleaning, mechanical preparation, and chemical preparation.The surface should be smooth, but not highly p
22、olished.Preparation of this surface must be compatible with the gage,bonding method, and base material.7.2 Erroneous gage readings may be caused by poor bond-ing of strain gages, which could be due to unremoved coatingssuch as paint, scale, rust, and oils. Poor bonding may also resultfrom applying g
23、ages to improperly prepared surfaces, such asmirror smooth finishes or surfaces containing deep pits andgouges.7.3 Strain gage manufacturers supply surface preparationsuggestions and recommendations. This information should bereviewed and considered when preparing base material sur-faces for the par
24、ticular gages selected.8. Gage InstallationGeneral8.1 All work must be performed with clean hands and tools.All materials needed should be assembled and readily availableat the gage installation location.8.2 The specific surface preparation procedures should be inaccordance with the instructions sup
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME123719932003STANDARDGUIDEFORINSTALLINGBONDEDRESISTANCESTRAINGAGES 安装 耦合 电阻 应变 PDF

链接地址:http://www.mydoc123.com/p-528233.html