ASTM E1235-2012 Standard Test Method for Gravimetric Determination of Nonvolatile Residue (NVR) in Environmentally Controlled Areas for Spacecraft《宇宙飞船在环境受控范围内的非挥发残留物 (NVR) 重量分析测定的.pdf
《ASTM E1235-2012 Standard Test Method for Gravimetric Determination of Nonvolatile Residue (NVR) in Environmentally Controlled Areas for Spacecraft《宇宙飞船在环境受控范围内的非挥发残留物 (NVR) 重量分析测定的.pdf》由会员分享,可在线阅读,更多相关《ASTM E1235-2012 Standard Test Method for Gravimetric Determination of Nonvolatile Residue (NVR) in Environmentally Controlled Areas for Spacecraft《宇宙飞船在环境受控范围内的非挥发残留物 (NVR) 重量分析测定的.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1235 08 E1235 12Standard Test Method forGravimetric Determination of Nonvolatile Residue (NVR) inEnvironmentally Controlled Areas for Spacecraft1This standard is issued under the fixed designation E1235; the number immediately following the designation indicates the year oforiginal ado
2、ption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of nonvolatile residue (NVR)
3、fallout in environmentally controlled areas used forthe assembly, testing, and processing of spacecraft.1.2 The NVR of interest is that which is deposited on sampling plate surfaces at room temperature: it is left to the user to inferthe relationship between the NVR found on the sampling plate surfa
4、ce and that found on any other surfaces.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatoryli
5、mitations prior to use.1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterE1234 Practice for Handling, Transporting, and Installing Nonvolatile R
6、esidue (NVR) Sample Plates Used in EnvironmentallyControlled Areas for SpacecraftF50 Practice for Continuous Sizing and Counting of Airborne Particles in Dust-Controlled Areas and Clean Rooms UsingInstruments Capable of Detecting Single Sub-Micrometre and Larger Particles2.2 ISO Standards:314644-1 C
7、leanrooms and Associated Controlled EnvironmentsPart 1: Classification of Air Cleanliness14644-2 Cleanrooms and Associated Controlled EnvironmentsPart 2: Specifications for Testing and Monitoring to ProveContinued Compliance with ISO 14644-114951-3 Space SystemsFluid CharacteristicsPart 3: Nitrogen2
8、.3 U.S. Federal Standard:4FED-STD-209E Airborne Particulate Cleanliness Classes in Cleanrooms and Clean Zones2.4 Institute of Environmental Sciences and Technology:5IEST-RP-CC001.3 HEPA and ULPA FiltersIEST-RP-CC007.1 Testing ULPA FiltersIEST-RP-CC034.1 HEPA and ULPA Filter Leak TestsIEST-STD-CC1246
9、 Product Cleanliness Levels and Contamination Control Program2.5 American National Standards Institute:3ANSI/ASME B46.1-1985B46.1-2009 Surface Texture (Surface Roughness, Waviness, and Lay)2.6 Other:Industrial Ventilation, A Manual of Recommended Practice, Latest Edition6SMC-TR-95-28, Nonvolatile Re
10、sidue Solvent Replacement, U.S. Air Force Space and Missile Systems Center, 1 March 199543. Terminology3.1 Definitions:3.1.1 ISO Class N (airborne particulate cleanliness class), nlevel of airborne particulate concentrations as defined in ISO14644-1 and 14644-2, where 10N is the maximum allowable co
11、ncentration (particles/m3).3.1.1.1 Discussion2 For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3 Available fro
12、m American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4 Available from Standardization Documents Order Desk, Bldg. 4, Section D,700 Robbins Ave., Philadelphia, PA, 19111-5094, Attn.: NPODS.5 Available from Institute of Environmental Sciences
13、, 940 E. NorthwestHighway, Mount Prospect, IL 60056.6 Available from Committee on Industrial Ventilation, PO Box 16153, Lansing,MI 48901.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1The considered particle sizes (lower threshold va
14、lues) applicable for classification with ISO 14644-1 are limited to the range from0.1 through 5 m. Particles larger than 5 m (macroparticles) may be expressed in accordance with Annex E of ISO 14644-1.3.1.2 FS209 class, nthe level of cleanliness specified by the maximum allowable number of particles
15、/ft3 of air as defined inFED-STD-209E.3.1.2.1 DiscussionThis is provided for information and to facilitate the transition to the use of the ISO classification standard (ISO 14644-1).3.1.3 bumping, nuneven boiling of a liquid caused by irregular rapid escape of large bubbles of highly volatile compon
16、entsas the liquid mixture is heated or exposed to vacuum.3.1.4 clean area, na general term that includes cleanrooms, controlled areas, good housekeeping areas, and other areas thathave contamination control by physical design and specified operating procedures.3.1.5 clean zone, na defined space in w
17、hich the contamination is controlled to meet specified cleanliness levels.3.1.5.1 DiscussionThe clean zone may be open or enclosed and may or may not be located within a cleanroom.3.1.6 contaminant, nunwanted molecular and particulate matter that could affect or degrade the performance of thecompone
18、nts upon which they reside.3.1.7 contamination, na process of contaminating.3.1.8 controlled area, nan environmentally controlled area, operated as a cleanroom, with two prefilter stages but without thefinal stage of HEPA (or better) filters used in cleanrooms.3.1.8.1 DiscussionOnly rough filters (5
19、0 to 60 % efficiency) and medium efficiency filters (80 to 85 % efficiency) are required for a controlled area.The maximum allowable airborne particle concentrations are ISO Class 8.5 (FS209 Class 283 000) area for particles 0.5 m andISO Class 8 (FS209 Class 100 000) for particles 5.0 m.3.1.9 enviro
20、nmentally controlled areas, n a general term that includes cleanrooms, controlled areas, good housekeeping areas,and other enclosures that are designed to provide an environment suitable for people or products.3.1.9.1 DiscussionThe environmental components that are controlled include, but are not be
21、 limited to, air purity, temperature, humidity, materials,garments, and personnel activities.3.1.10 facility (clean facility), nthe total real property required to accomplish the cleanroom functions.3.1.10.1 DiscussionIn addition to the cleanroom and associated clean areas, this includes utility roo
22、ms, storage areas, offices, lockers, washrooms, andother areas that do not necessarily require precise environmental control.3.1.11 good housekeeping area, nan environmentally controlled area without quantitative cleanliness requirements butmaintained in a visibly clean condition.3.1.11.1 Discussion
23、Office, laboratory, and storage areas with air conditioning and janitorial service are typical of good housekeeping areas.3.1.12 HEPA (high effciency particulate air) filter, na filter for air with a removal efficiency in excess of 99.97 % for 0.3-mparticles.1 This test method is under the jurisdict
24、ion of ASTM Committee E21 on Space Simulation and Applications of Space Technology and is the responsibility of SubcommitteeE21.05 on Contamination.Current edition approved May 1, 2008Nov. 1, 2012. Published June 2008November 2012. Originally approved in 1988. Last previous edition approved in 20012
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME12352012STANDARDTESTMETHODFORGRAVIMETRICDETERMINATIONOFNONVOLATILERESIDUENVRINENVIRONMENTALLYCONTROLLEDAREASFORSPACECRAFT

链接地址:http://www.mydoc123.com/p-528232.html