ASTM E1114-2009 Standard Test Method for Determining the Size of Iridium-192 Industrial Radiographic Sources《测定铱192工业射线源尺寸的标准试验方法》.pdf
《ASTM E1114-2009 Standard Test Method for Determining the Size of Iridium-192 Industrial Radiographic Sources《测定铱192工业射线源尺寸的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1114-2009 Standard Test Method for Determining the Size of Iridium-192 Industrial Radiographic Sources《测定铱192工业射线源尺寸的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1114 09Standard Test Method forDetermining the Size of Iridium-192 Industrial RadiographicSources1This standard is issued under the fixed designation E 1114; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the size ofan Iridium-192 radiographic source. The determination isbase
3、d upon measurement of the image of the Iridium metalsource in a projection radiograph of the source assembly andcomparison to the measurement of the image of a referencesample in the same radiograph.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard
4、. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associa
5、ted with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 999 Guide for Controlling the Quality of Industrial Ra-dio
6、graphic Film ProcessingE 1316 Terminology for Nondestructive ExaminationsE 1815 Test Method for Classification of Film Systems forIndustrial RadiographyE 2445 Practice for Qualification and Long-Term Stabilityof Computed Radiology SystemsE 2597 Practice for Manufacturing Characterization ofDigital D
7、etector Arrays2.2 Other International Standards:EN 12579 Industrial RadiographyRadiographic Methodfor the Determination of the Source Size for Radioiso-topes33. Terminology3.1 For definitions of terms relating to this test method, referto Terminology E 1316.4. Significance and Use4.1 One of the fact
8、ors affecting the quality of a radiographicimage is geometric unsharpness. The degree of geometricunsharpness is dependent upon the size of the source, thedistance between the source and the object to be radiographed,and the distance between the object to be radiographed and thefilm or digital detec
9、tor. This test method allows the user todetermine the size of the source and to use this result toestablish source to object and object to film or detectordistances appropriate for maintaining the desired degree ofgeometric unsharpness.NOTE 1The European standard CEN EN 12579 describes a simplifiedp
10、rocedure for measurement of source sizes of Ir-192, Co-60 and Se-75.The resulting source size of Ir-192 is comparable to the results obtained bythis test method.5. Apparatus5.1 Subject Iridium-192 Source, the source size of which isto be determined. The appropriate apparatus and equipment forthe saf
11、e storage, handling, and manipulation of the subjectsource, such as a radiographic exposure device (also referred toas a gamma ray projector or camera), remote control, sourceguide tube, and source stop are also required.5.2 Reference Sample (see Figs. 1-3)The referencesample shall be of material wh
12、ich is not radioactive. Therecommended material is Iridium. However, substitutes such asplatinum, tungsten or other material of similar radiopacity may1This test method is under the jurisdictioin of ASTM Committee E07 onNondestructive Testing and is the direct responsibility of Subcommittee E07.01 o
13、nRadiology (X and Gamma) Method.Current edition approved June 1, 2009. Published July 2009. Originally approvedin 1986. Last previous edition approved in 2003 as E 1114 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For An
14、nual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C
15、700, West Conshohocken, PA 19428-2959, United States.be used. The sample should be of the same geometric shape asthe subject source, should be approximately the same size asthe subject source, and should be positioned on or within ashim or envelope to simulate the source capsule wall. Theresulting r
16、adiographic contrast, with reference to adjacentbackground density of the image of the reference sample,should be approximately the same as that of the subject source.The actual dimensions of the reference sample should bedetermined to the nearest 0.025 mm (0.001 in.).5.3 X-ray Generator, capable of
17、 producing a radiationintensity (roentgen per hour at one metre) at least ten timesgreater than that produced by the subject source. Examples oftypical X-ray generator output requirements that satisfy thiscriterion are presented in Table 1.5.4 Film systemsOnly film systems having cognizantengineerin
18、g organization approval or meeting the system classrequirements of Test Method E 1815, for system classes I, II orSpecial, shall be used. Selection of film systems should bedetermined by such factors as the required radiographic qualitylevel, equipment capability, materials and so forth. The filmsys
19、tem selected shall be capable of demonstrating the requiredimage quality. No intensifying screens shall be used. Radio-graphic films shall be processed in accordance with GuideE 999.5.5 Image Measurement ApparatusThis apparatus is usedto measure the size of the image of the spot. The apparatusshall
20、be an optical comparator with built-in graticule with 0.1mm divisions or 0.001 in. divisions and magnification of 53 to103.5.6 Digital DetectorsDigital detectors, which are eitherimaging plates or digital detector arrays, may be used as filmreplacement. The digital detector shall possess a pixel pit
21、chwhich is at least 40 times smaller than the nominal source sizeto measure and a basic spatial resolution smaller than120 of thenominal source size. The basic spatial resolution shall bemeasured in accordance with the procedure of Practice E 2597for DDAs or Practice E 2445 for the imaging plate sca
22、nnersystem or taken from manufacturer statements. In the area offree beam a detector SNRD 100 shall be achieved. TheFIG. 1 Reference Sample in Standard Source EncapsulationFIG. 2 Alternate Reference Sample ArrangementFIG. 3 Alternate Reference Sample ArrangementTABLE 1 Examples of Typical X-ray Gene
23、rator OutputRequirements for Related Iridium192Source ActivitiesSubject Iridium192SourceRadiationTypical X-ray GeneratorOutput RequirementsActivity(Curie)Output(R/h at 1 m)Potential Current30 14.4 160 kV 5 mAor 200 kV 3 mA100 48.0 160 kV 10 mAor 250 kV 4 mA200 96.0 160 kV 20 mAor 250 kV 8 mAor 300 k
24、V 6 mAE1114092measurement procedure of the SNR shall be in accordance withthe procedure of Practice E 2597 for DDAs or Practice E 2445for the imaging plate scanner system.5.7 Evaluation of Digital ImagesDigital images shall beevaluated by an image processing software with contrast,brightness, profil
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME11142009STANDARDTESTMETHODFORDETERMININGTHESIZEOFIRIDIUM192INDUSTRIALRADIOGRAPHICSOURCES 测定 192

链接地址:http://www.mydoc123.com/p-527935.html