ASTM E1114-2003 Standard Test Method for Determining the Focal Size of Iridium-192 Industrial Radiographic Sources《测定铱192工业X射线源的聚焦尺寸的标准试验方法》.pdf
《ASTM E1114-2003 Standard Test Method for Determining the Focal Size of Iridium-192 Industrial Radiographic Sources《测定铱192工业X射线源的聚焦尺寸的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1114-2003 Standard Test Method for Determining the Focal Size of Iridium-192 Industrial Radiographic Sources《测定铱192工业X射线源的聚焦尺寸的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1114 03Standard Test Method forDetermining the Focal Size of Iridium-192 IndustrialRadiographic Sources1This standard is issued under the fixed designation E 1114; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the focalsize of an iridium-192 radiographic source. The determi
3、nationis based upon measurement of the image of the iridium metalsource in a projection radiograph of the source assembly andcomparison to the measurement of the image of a referencesample in the same radiograph.1.2 This standard does not purport to address all of thesafety concerns, if any, associa
4、ted with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:E 999 Guide for Controlling the Quality of Industrial Ra-diog
5、raphic Film Processing2E 1316 Terminology for Nondestructive Examinations2E 1815 Test Method for Classification of Film Systems forIndustrial Radiography23. Terminology3.1 For definitions of terms relating to this test method, referto Terminology E 1316.4. Significance and Use4.1 One of the factors
6、affecting the quality of a radiographicimage is geometric unsharpness. The degree of geometricunsharpness is dependent upon the focal size of the source, thedistance between the source and the object to be radiographed,and the distance between the object to be radiographed and thefilm. This test met
7、hod allows the user to determine the focalsize of the source and to use this result to establish source toobject and object to film distances appropriate for maintainingthe desired degree of geometric unsharpness.5. Apparatus5.1 Subject Iridium-192 Source, the focal size of which is tobe determined.
8、 The appropriate apparatus and equipment forthe safe storage, handling, and manipulation of the subjectsource, such as a radiographic exposure device (also referred toas a gamma ray projector or camera), remote control, sourceguide tube, and source stop are also required.5.2 Reference Sample (see Fi
9、gs. 1-3)The referencesample shall be of material which is not radioactive. Therecommended material is iridium. However, substitutes such asplatinum, tungsten or other material of similar radiopacity maybe used. The sample should be of the same geometric shape asthe subject source, should be approxim
10、ately the same size asthe subject source, and should be positioned on or within ashim or envelope to simulate the source capsule wall. Theresulting radiographic contrast, with reference to adjacentbackground density of the image of the reference sample,should be approximately the same as that of the
11、 subject source.The actual dimensions of the reference sample should bedetermined to the nearest 0.025 mm 0.001 in.5.3 X-ray Generator, capable of producing a radiationintensity (roentgen per hour at one metre) at least ten timesgreater than that produced by the subject source. Examples oftypical X-
12、ray generator output requirements that satisfy thiscriterion are presented in Table 1.5.4 Film systemsOnly film systems having cognizantengineering organization approval or meeting the system classrequirements of Test Method E 1815, for system classes I, II orSpecial, shall be used. Selection of fil
13、m systems should bedetermined by such factors as the required radiographic qualitylevel, equipment capability, materials and so forth. The filmsystem selected shall be capable of demonstrating the requiredimage quality. No intensifying screens shall be used. Radio-graphic films shall be processed in
14、 accordance with GuideE 999.1This test method is under the jurisdictioin of ASTM Committee E07 onNondestructive Testing and is the direct responsibility of Subcommittee E07.01 onRadiology (X and Gamma) Method.Current edition approved March 10, 2003. Published May 2003. Originallyapproved in 1986. La
15、st previous edition approved in 1997 as E 1114 92 (1997)e1.2Annual Book of ASTM Standards, Vol 03.03.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.5 Image Measurement ApparatusThis apparatus is usedto measure the size of the imag
16、e of the focal spot. Theapparatus shall be an optical comparator with built-in graticulewith 0.1 mm divisions or 0.001 in. divisions and magnificationof 53 to 103.6. Procedure6.1 Set up the exposure arrangement as shown in Figs. 4-7.Position the X-ray tube directly over the center of the film. Thefi
17、lm plane must be normal to the central ray of the X-ray beam.The X-ray focal spot should be 0.90 m 36 in. from the film.Position the reference sample and apparatus used to locate thesubject source (source stop) as close together as possible anddirectly over the center of the film. The plane of the s
18、ource stopand reference sample must be parallel to the film and normal tothe central ray of the X-ray beam. The source stop andreference sample should be 0.15 m 6 in. from the film. Thesource stop should be connected to the radiographic exposuredevice by the shortest source guide tube practicable in
19、 order tominimize fogging of the film during source transit.6.2 Place identification markers to be imaged on the film toidentify, as a minimum, the identification (serial number) of thesubject source, the size of the reference sample, the identifi-cation of the organization performing the determinat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME11142003STANDARDTESTMETHODFORDETERMININGTHEFOCALSIZEOFIRIDIUM192INDUSTRIALRADIOGRAPHICSOURCES 测定

链接地址:http://www.mydoc123.com/p-527934.html