《ASTM D7546-2015 0478 Standard Test Method for Determination of Moisture in New and In-Service Lubricating Oils and Additives by Relative Humidity Sensor《采用相对湿度传感器测定新润滑油和使用中润滑油及添加剂中.pdf》由会员分享,可在线阅读,更多相关《ASTM D7546-2015 0478 Standard Test Method for Determination of Moisture in New and In-Service Lubricating Oils and Additives by Relative Humidity Sensor《采用相对湿度传感器测定新润滑油和使用中润滑油及添加剂中.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7546 15Standard Test Method forDetermination of Moisture in New and In-Service LubricatingOils and Additives by Relative Humidity Sensor1This standard is issued under the fixed designation D7546; the number immediately following the designation indicates the year oforiginal adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the quantitative determinationof water in new and in-s
3、ervice lubricating oils and additives inthe range of 10 mg/kg to 100 000 mg kg (0.001 wt. wt. to10 % wt./wt.) using a relative humidity (RH) sensor. Methanol,acetonitrile, and other compounds are known to interfere withthis test method.1.2 The values stated in SI units are to be regarded asstandard.
4、 No other units of measurement are included in thisstandard.1.3 WarningSamples tested in this test method can beflammable, explosive, and toxic. Use caution when handlingthem before and after testing.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its
5、 use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D4175 Terminology Relating to Petroleum, PetroleumProducts, and Lubrican
6、ts3. Terminology3.1 For definitions of terms used in this test method, refer toTerminology D4175.4. Summary of Test Method4.1 An aliquot of sample is heated to a temperature between25 C to 200 C with 1 C resolution. The sample is maintainedat a constant temperature for the duration of the test. Dry
7、inertgas flows over the heated sample and carries the thermallyevolved moisture past a relative humidity sensor. The sensorsignal is integrated over time to provide a measurement of totalmass of water in the sample.4.2 The sample injection may be done either by mass or byvolume.4.3 This test method
8、utilizes anhydrous compressed gas orambient air passed through a desiccant to prevent contamina-tion from moisture present in the atmosphere.4.4 Viscous samples can be analyzed by preheating them toplace them in a more fluid state allowing them to be drawn intoa syringe, or by dissolving them in a c
9、ompatible anhydroussolvent. Care should be taken to minimize time spent preheat-ing samples to prevent moisture loss.5. Significance and Use5.1 Knowledge of the water content of lubricating oils,additives, and similar products is important in the manufacture,purchase, sale, transfer, or use of such
10、petroleum products tohelp in predicting their quality and performance characteristics.5.2 For lubricating oils, the presence of water can lead topremature corrosion and wear, an increase in the debris loadresulting in diminished lubrication and premature plugging offilters, impedance to the effect o
11、f additives, and undesirablesupport of deleterious bacterial growth.6. Interferences6.1 Methanol and acetonitrile are known to interfere withthe determination of moisture by this test method. Thesesubstances contribute to a high bias in the final results. Moregenerally, some short-chained polar mole
12、cules mimic the effectof water at the RH sensor resulting in a positive interference.Strong polar solvents, such as n-methyl-pyrrolidone, can se-verely damage the RH sensor.7. Apparatus7.1 Sample Injection Moisture Analyzer Apparatus:7.1.1 Flow Regulator, capable of maintaining the carrier gasflow r
13、ate within the manufacturers specified conditions.7.1.2 Flow Meter, capable of measuring the carrier gas flowrate within the manufacturers specified conditions.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct respo
14、nsibility ofSubcommittee D02.96.02 on Chemistry for the Evaluation of In-Service Lubricants.Current edition approved April 1, 2015. Published June 2015. Originallyapproved in 2009. Last previous edition approved in 2009 as D7546 09. DOI:10.1520/D7546-15.2For referenced ASTM standards, visit the ASTM
15、 website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Har
16、bor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States17.1.3 Stainless Steel Sample Coil, for heating the sample asit is transported from the sample inlet to the sump.7.1.4 Sample Coil Heater, capable of maintaining thesample coil temperature within 1 C of the programmedtemperature
17、between 25 C and 200 C.7.1.5 Sample Delivery System, provides programmable vari-able speed injection of the sample into the coil.7.1.6 Sump, allows for collection of the sample at thebottom of the sample coil during testing and discharge of thesample to a waste container after testing is completed.7
18、.1.7 Manifold, which provides:7.1.7.1 A thermally stable port for mounting and operationof the relative humidity sensor.7.1.7.2 Inlet and outlet ports for the carrier gas.7.1.8 Relative Humidity (RH) Sensor, a capacitive sensingelement that measures the relative humidity of the carrier gas.7.1.9 Mic
19、rocontroller, which provides:7.1.9.1 Capability of integrating and converting the RHsensor signal.7.1.9.2 Capability of controlling the temperature of the coilheater, and the sensor manifold.7.1.9.3 Capability of controlling the speed of the sampledelivery system.7.1.10 Balance, external, with 1 mg
20、precision for weighingsample.7.2 Headspace Vial Moisture Analyzer Apparatus:7.2.1 Flow Regulator, capable of maintaining the carrier gasflow rate within the manufacturers specified conditions.7.2.2 Flow Meter, capable of measuring the carrier gas flowrate within the manufacturers specified condition
21、s.7.2.3 Sample Heating Chamber, capable of maintaining thesample chamber temperature within 1 C of the programmedtemperature between 25 C and 200 C.7.2.4 Sample Delivery System, transports vial into sampleheating chamber.7.2.5 Manifold, which provides:7.2.5.1 A thermally stable port for mounting and
22、 operationof the relative humidity sensor7.2.5.2 Inlet and outlet ports for the carrier gas.7.2.6 Relative Humidity (RH) Sensor, a capacitive sensingelement that measures the relative humidity of the carrier gas.7.2.7 Microcontroller, which provides:7.2.7.1 Capability of integrating and converting t
23、he RHsensor signal.7.2.7.2 Capability of controlling the temperature of thesample heating chamber, and the sensor manifold.7.2.7.3 Capability of controlling the speed of the sampledelivery system.7.2.8 Balance, external, with 1 mg precision for weighingsample.8. Reagents and Materials8.1 Carrier Gas
24、, any dry inert gas including, but not limitedto, dry air, nitrogen, helium, or argon.8.2 Water, deionized.8.3 For Sample Injection Moisture Analyzer:8.3.1 Traceable Syringe, traceable at the desired total massof water, typically 500 g (0.5 L).8.3.2 Glass or Plastic Syringe, 1 mL or 5 mL capacity.8.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD754620150478STANDARDTESTMETHODFORDETERMINATIONOFMOISTUREINNEWANDINSERVICELUBRICATINGOILSANDADDITIVESBYRELATIVEHUMIDITYSENSOR

链接地址:http://www.mydoc123.com/p-525766.html