《ASTM D7048-2004 Standard Guide for Applying Statistical Methods for Assessment and Corrective Action Environmental Monitoring Programs《环境监测程序评估和修正用统计方法的应用标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7048-2004 Standard Guide for Applying Statistical Methods for Assessment and Corrective Action Environmental Monitoring Programs《环境监测程序评估和修正用统计方法的应用标准指南》.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7048 04Standard Guide forApplying Statistical Methods for Assessment and CorrectiveAction Environmental Monitoring Programs1This standard is issued under the fixed designation D 7048; the number immediately following the designation indicates the year oforiginal adoption or, in the ca
2、se of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 The scope and purpose of this guidance is to present avariety of statistical approaches f
3、or assessment, complianceand corrective action environmental monitoring programs.Although the methods provided here are appropriate and oftenoptimal for many environmental monitoring problems, they donot preclude use of other statistical approaches that may beequally or even more useful for certain
4、site-specific applica-tions.1.2 In the following sections, complete details of selectstatistical procedures used in assessment and corrective actionprograms for environmental monitoring (soil, ground water,air, surface water, and waste streams) are presented.1.3 The statistical methodology described
5、 in the followingsections should be used as guidance. Other methods may alsobe appropriate based on site-specific conditions or for moni-toring situations or media that are not presented in thisdocument.1.4 This practice offers an organized collection of informa-tion or a series of options and does
6、not recommend a specificcourse of action. This document cannot replace education,experience and professional judgements. Not all aspects of thispractice may be applicable in all circumstances. This ASTMstandard is not intended to represent or replace the standard ofcare by which the adequacy of a gi
7、ven professional servicemust be judged without consideration of a projects manyunique aspects. The word Standard in the title of this documentonly means that the document has been approved through theASTM consensus process.1.5 This standard does not purport to address all of thesafety concerns, if a
8、ny, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory requirements prior to use.2. Referenced Documents2.1 ASTM Standards:2D 5092 Practice for Designing and Installation o
9、f GroundWater Monitoring Wells in AquifersD 5792 Practice for Generation of Environmental DataRelated to Waste Management Activities: Development ofData Quality ObjectivesD 6250 Practice for Deveration of Decision Points andConfidence Limits for Statistical Testing of Mean Concen-tration in Waste Ma
10、nagement DecisionsD 6312 Practice for Developing Appropriate Statistical Ap-proaches for Ground Water Detection Monitoring Pro-grams3. Terminology3.1 Definitions:3.1.1 assessment monitoringinvestigative monitoring thatis initiated after the presence of a contaminant has beendetected in ground water
11、above a relevant criterion at one ormore locations. The objective of the program is to determine ifthere is a statistical exceedance of a standard or criteria at aPotential Area of Concern (PAOC) or at the ground waterdischarging to surface water interface, and/or to quantify therate and extent of m
12、igration of constituents detected in groundwater above applicable criteria.3.1.2 compliance monitoringas specified under 40 CFR264.99, compliance monitoring is instituted when hazardousconstituents have been detected above a relevant criterion atthe compliance point during RCRA detection monitoring.
13、Ground-water samples are collected at the compliance point,facility property boundary, and upgradient monitoring wells foranalysis of hazardous constituents to determine if they areleaving the regulated unit at statistically significant concentra-tions above background.1This guide is under the juris
14、diction of ASTM Committee D18 on Soil and Rockand is the direct responsibility of Subcommittee D18.21 on Ground Water andVadose Zone Investigations.Current edition approved May 1, 2004. Published June 2004.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer
15、Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.3 corrective action monitoringunder
16、RCRA, correc-tive action monitoring is instituted when hazardous constitu-ents from a RCRA regulated unit have been detected atstatistically significant concentrations between the compliancepoint and the downgradient facility property boundary asspecified under 40 CFR 264.100. Corrective action moni
17、toringis conducted throughout a corrective action program that isimplemented to address ground-water contamination. At non-RCRA sites, corrective action monitoring is conductedthroughout the active period of corrective action to determinethe progress of remediation and to identify statistically sign
18、ifi-cant trends in ground-water contaminant concentrations.3.1.4 detection limit, DLthe true concentration at whichthere is a specified level of confidence (for example, 99 %confidence) that the true concentration is greater than zero.3.1.5 detection monitoringa program of monitoring forthe express
19、purpose of determining whether or not there hasbeen a release of a contaminant to ground water. Under RCRA,Detection Monitoring involves collection of ground-watersamples from compliance point and upgradient monitoringwells on a semi-annual basis for analysis of hazardous con-stituents of concern, a
20、s specified under 40 CFR 264.98. Resultsare evaluated to determine if there is a statistically significantexceedance of the ground-water protection criterion and/orbackground. At non-RCRA sites, monitoring is conducted in asimilar manner and results are compared to criteria to deter-mine if there is
21、 a statistically significant exceedance.3.1.6 direct push samplingground-water sampling con-ducted with a device that is temporarily pushed into the groundwith a hydraulic system or with a hammer. After ground-watersample collection, the device is removed from the ground.Examples include Geoprobet,
22、Hydropuncht direct push, andenvironmental soil probe.3.1.7 false negative ratethe rate at which the statisticalprocedure does not indicate contamination when contamina-tion is present.3.1.8 false positive ratethe rate at which the statisticalprocedure indates contamination when contamination is notp
23、resent.3.1.9 lognormal distributiona frequency distributionwhose logarithm follows a normal distribution.3.1.10 lower confidence limit, LCLa lower limit that has aspecified probability (for example, 95 %) of including the trueconcentration (or other parameter). Taken together with theupper confidenc
24、e limit, forms a confidence interval that willinclude the true concentration with confidence level thataccounts for both tail areas (for example, 90 %).3.1.11 lower prediction limit, LPLa statistical estimate ofthe minimum concentration that will provide a lower bound forthe next series of k measure
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD70482004STANDARDGUIDEFORAPPLYINGSTATISTICALMETHODSFORASSESSMENTANDCORRECTIVEACTIONENVIRONMENTALMONITORINGPROGRAMS

链接地址:http://www.mydoc123.com/p-524371.html