ASTM D6764-2002(2007) Standard Guide for Collection of Water Temperature Dissolved-Oxygen Concentrations Specific Electrical Conductance and pH Data from Open Channels《从明渠中采集水温、溶解氧.pdf
《ASTM D6764-2002(2007) Standard Guide for Collection of Water Temperature Dissolved-Oxygen Concentrations Specific Electrical Conductance and pH Data from Open Channels《从明渠中采集水温、溶解氧.pdf》由会员分享,可在线阅读,更多相关《ASTM D6764-2002(2007) Standard Guide for Collection of Water Temperature Dissolved-Oxygen Concentrations Specific Electrical Conductance and pH Data from Open Channels《从明渠中采集水温、溶解氧.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6764 02 (Reapproved 2007)Standard Guide forCollection of Water Temperature, Dissolved-OxygenConcentrations, Specific Electrical Conductance, and pHData from Open Channels1This standard is issued under the fixed designation D 6764; the number immediately following the designation indic
2、ates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide describes procedures to collect
3、 cross-sectional means of temperature, dissolved oxygen, specificelectrical conductance, and pH of water flowing in openchannels.1.2 This guide provides guidelines for preparation andcalibration of the equipment to collect cross-sectional means oftemperature, dissolved oxygen, specific electrical co
4、nductance,and pH of water flowing in open channels.1.3 This guide describes what equipment should be used tocollect cross-sectional means of temperature, dissolved oxy-gen, specific electrical conductance, and pH of water flowing inopen channels.1.4 This guide covers the cross-sectional means of tem
5、pera-ture, dissolved oxygen, specific electrical conductance, and pHof fresh water flowing in open channels.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety
6、and health practices and determine the applica-bility of regulatory requirements prior to use.2. Referenced Documents2.1 ASTM Standards:2D 888 Test Methods for Dissolved Oxygen in WaterD 1125 Test Methods for Electrical Conductivity and Re-sistivity of WaterD 1129 Terminology Relating to WaterD 1293
7、 Test Methods for pH of WaterD 4410 Terminology for Fluvial SedimentD 4411 Guide for Sampling Fluvial Sediment in MotionD 5464 Test Methods for pH Measurement of Water of LowConductivity3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this guide, refer toTerminology D 1129 and D
8、4410.3.2 Definitions of Terms Specific to This Standard:3.2.1 electronic temperature sensoran electrical devicethat converts changes in resistance to a readout calibrated intemperature units. Thermistors and resistance temperaturedetectors are examples of electronic temperature sensors.3.2.2 thermom
9、eterany device used to measure tempera-ture, consisting of a temperature sensor and some type ofcalibrated scale or readout device.4. Summary of Guide4.1 This guide establishes criteria and describes proceduresfor the collection of cross-sectional means of temperature,dissolved oxygen (DO), specific
10、 electrical conductance (SC),and pH of water flowing in open channels.4.2 This guide provides only generic guidelines for equip-ment use and maintenance. Field personnel must be familiarwith the instructions provided by equipment manufacturers.There are a large variety of available field instruments
11、 and fieldinstruments are being continuously updated or replaced usingnewer technology. Field personnel are encouraged to contactequipment manufacturers for answers to technical questions.5. Significance and Use5.1 This guide describes stabilization criteria for recordingfield measurements of Temper
12、ature, DO, SC, and pH.5.2 This guide describes the procedures used to calibrateand check meters to be used in the field to records thesemeasurements and the procedures to be use in the field toobtain these data.5.3 This guide describes quality assurance procedures to befollowed when obtaining cross-
13、sectional means of temperature,dissolved oxygen, specific electrical conductance, and pH ofwater flowing in open channels.1This guide is under the jurisdiction of ASTM Committee D19 on Water and isthe direct responsibility of Subcommittee D19.07 on Sediments, Geomorphology,and Open-Channel Flow.Curr
14、ent edition approved June 15, 2007. Published July 2007. Originallyapproved in 2002. Last previous edition approved in 2002 as D 6764 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume i
15、nformation, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.4 Field measurement must accurately represent the waterflowing in the open channel being measured. Methods
16、need tobe used that will result in an accurate representation of themean of the parameter of interest. Procedures must be used thatwill take into consideration the variation in the parameteracross the sections and with depth.5.5 Temperature and DO must be measured directly in thewater in the open ch
17、annel. SC and pH are often measured insitu, but also may be measured in a subsample of a compositesample collected using discharge-weighted methods.6. ProcedureGeneral Comments6.1 Field measurements should represent, as closely aspossible, the natural condition of the surface-water system atthe time
18、 of sampling. Field teams must determine if theinstruments and method to be used will produce data of thetype and quality required to fulfill study needs. Experience andknowledge of field conditions often are indispensable fordetermining the most accurate field-measurement value.6.1.1 To ensure the
19、quality of the data collected (1)3:6.1.1.1 Calibration is required at the field site for mostinstruments. Make field measurements only with calibratedinstruments.6.1.1.2 Each field instrument must have a permanent log-book for recording calibrations and repairs. Review the log-book before leaving fo
20、r the field.6.1.1.3 Test each instrument (meters and sensors) beforeleaving for the field. Practice your measurement technique ifthe instrument or measurement is new to you.6.1.1.4 Have backup instruments readily available and ingood working condition.6.1.2 Before making field measurements, sensors
21、must beallowed to equilibrate to the temperature of the water beingmonitored. Sensors have equilibrated adequately when instru-ment readings have “stabilized,” that is, when the variabilityamong measurements does not exceed an established criterion.The criteria for stabilized field readings are defi
22、ned operation-ally in Table 1, for a set of three or more sequential measure-ments. The natural variability inherent in surface water at thetime of sampling generally falls within these stability criteriaand reflects the accuracy that should be attainable with acalibrated instrument.6.1.3 Allow at l
23、east 60 s (or follow the manufacturersguidelines) for sensors to equilibrate with sample water. Takeinstrument readings until the stabilization criteria in Table 1 aremet. Record the median of the final three or more readings asthe value to be reported for that measurement point.6.2 Locating Points
24、of Measurement in Cross-Section:6.2.1 The location and the number of field measurementsdepend on study objectives. Generally, a single set of field-measurement data is used to represent an entire stream crosssection at a sampling site and can be useful when calculatingchemical loads.6.2.2 To obtain
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD676420022007STANDARDGUIDEFORCOLLECTIONOFWATERTEMPERATUREDISSOLVEDOXYGENCONCENTRATIONSSPECIFICELECTRICALCONDUCTANCEANDPHDATAFROMOPENCHANNELS

链接地址:http://www.mydoc123.com/p-523502.html